M D R - 1 0 0 96W Single Output Industrial DIN Rail Power Supply
series
Features :
Universal AC input / Full range
Protections: Short circuit / Overload / Over voltage / Over temperature
ZCS/ZVS technology to reduce power dissipation
Cooling by free air convection
Can be installed on DIN rail TS-35/7.5 or 15
DC OK relay contact
No load power consumption<1W
LED indicator for power on
100% full load burn-in test
3 years warranty
SPECIFICATION
MODEL
MDR-100-12
MDR-100-24
MDR-100-48
OUTPUT
DC VOLTAGE
12V
24V
RATED CURRENT
7.5A
4A
CURRENT RANGE
0 ~ 7.5A
0 ~ 4A
RATED POWER
90W
96W
RIPPLE & NOISE (max.) Note.2 120mVp-p
150mVp-p
VOLTAGE ADJ. RANGE
12 ~ 15V
24 ~ 30V
VOLTAGE TOLERANCE Note.3 1.0%
1.0%
LINE REGULATION
1.0%
1.0%
LOAD REGULATION
1.0%
1.0%
SETUP, RISE TIME Note.5 3000ms, 50ms/230VAC 3000ms, 50ms/115VAC at full load
HOLD UP TIME (Typ.)
50ms/230VAC 20ms/115VAC at full load
48V
2A
0 ~ 2A
96W
200mVp-p
48 ~ 56V
1.0%
1.0%
1.0%
VOLTAGE RANGE
Note.6 85 ~ 264VAC 120 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF 0.95/230VAC PF 0.98/115VAC at full load
INPUT EFFICIENCY (Typ.)
85%
86%
88%
AC CURRENT (Typ.)
1.3A/115VAC 0.8A/230VAC
INRUSH CURRENT (Typ.) COLD START 30A/115VAC 60A/230VAC
LEAKAGE CURRENT
<1mA / 240VAC
OVERLOAD
PROTECTION OVER VOLTAGE
OVER TEMPERATURE
105 ~ 150% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
15.6 ~ 18V
31.2 ~ 36V
57.6 ~ 64.8V
Protection type : Shut down o/p voltage, re-power on to recover
90 10 (RTH2) detect on heatsink of power transistor
Protection type : Shut down o/p voltage, re-power on to recover
FUNCTION DC OK SIGNAL
Relay contact rating(max.): 30V/1A resistive
WORKING TEMP.
-10 ~ +60 (Refer to output load derating curve)
WORKING HUMIDITY
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03%/ (0 ~ 50
VIBRATION
Component : 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes ; Mounting : Compliance to IEC60068-2-6
SAFETY STANDARDS
UL508, TUV EN60950-1 approved
SAFETY &
EMC
(Note 4)
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55011, EN55022 (CISPR22), EN61204-3 Class B
Compliance to EN61000-3-2,-3
EMS IMMUNITY
Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11, ENV50204, EN55024, EN61000-6-2, EN61204-3, heavy industry level, criteria A
MTBF
346K hrs min. MIL-HDBK-217F (25 )
OTHERS DIMENSION
55*90*100mm (W*H*D)
PACKING
0.42Kg; 30pcs/13.6Kg/0.82CUFT
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
6. Deating maybe needed under low input voltages, please check the derating curve for more detail.
File Name:MDR-100-SPEC 2011-03-22