LPV-60_12 Datasheet, PDF (1/2 Pages) Mean Well Enterprises Co., Ltd. – 60W Single Output Switching Power Supply
60W Single Output Switching Power Supply
LPV-60 series
Features :
Constant voltage design
Universal AC input / Full range
Withstand 300VAC surge input for 5 seconds
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
Fully encapsulated with IP67 level (Note.8)
Fully isolated plastic case
Class power unit, no FG
Class 2 power unit
Pass LPS
Suitable for LED lighting and moving sign applications (Note.7)
100% full load burn-in test
Low cost, high reliability
2 years warranty
SPECIFICATION
LPS IP67
( for 48V only)
( except for 5V,48V )
MODEL
LPV-60-5
LPV-60-12
LPV-60-15
LPV-60-24
LPV-60-36
LPV-60-48
OUTPUT
DC VOLTAGE
5V
12V
15V
24V
36V
48V
RATED CURRENT
8A
5A
4A
2.5A
1.67A
1.25A
CURRENT RANGE
0 ~ 8A
0 ~ 5A
0 ~ 4A
0 ~ 2.5A
0 ~ 1.67A
0 ~ 1.25A
RATED POWER
40W
60W
60W
60W
60W
60W
RIPPLE & NOISE (max.) Note.2 80mVp-p
120mVp-p
120mVp-p
150mVp-p
150mVp-p
150mVp-p
VOLTAGE TOLERANCE Note.3 8.0%
5.0%
LINE REGULATION
1.0%
LOAD REGULATION
6.0%
2.0%
SETUP, RISE TIME Note.6 500ms, 20ms / 230VAC 500ms, 20ms / 115VAC at full load(for 5~36V) ; 500ms, 30ms / 230VAC 500ms, 30ms / 115VAC at full load(for 48V)
HOLD UP TIME (Typ.)
50ms/230VAC 16ms/115VAC at full load
VOLTAGE RANGE
Note.4 90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.)
76%
83%
83%
86%
86%
86%
INPUT
AC CURRENT (Typ.)
1.2A/115VAC 1A/230VAC
INRUSH CURRENT(max.) COLD START 30A/115VAC 60A/230VAC
LEAKAGE CURRENT
0.25mA / 240VAC
OVERLOAD
PROTECTION
OVER VOLTAGE
110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
5.75 ~ 6.75V
13.8 ~ 16.2V
17.25 ~ 20.25V
27.6 ~ 32.4V
Protection type : Shut down o/p voltage, re-power on to recover
41.4 ~ 48.6V
55.2 ~ 64.8V
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
-30 ~ +70 (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH
0.03%/ (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL879(except for LPV-60-5), UL1310(except for LPV-60-5), CSA C22.2 No. 207-M89(except for LPV-60-5, LPV-60-48),
CAN/CSA C22.2 No. 223-M91(except for LPV-60-5,LPV-60-48), IP67 approved ; design refer to TUV EN60950-1
SAFETY & WITHSTAND VOLTAGE
I/P-O/P:3KVAC
EMC
ISOLATION RESISTANCE I/P-O/P:>100M Ohms / 500VDC / 25 / 70% RH
EMC EMISSION
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2 Class A, EN61000-3-3
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A
MTBF
732Khrs min. MIL-HDBK-217F (25 )
OTHERS DIMENSION
162.5*42.5*32mm (L*W*H)
PACKING
0.4Kg; 32pcs/13.8Kg/0.56CUFT
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. The unit might not be suitable for lighting applications in EU countries. Please check with your local authorities for the possible use of the unit.
8. Suitable for indoor use or outdoor use without direct sunlight exposure. Please avoid immerse in the water over 30 minute.
File Name:LPV-60-SPEC 2012-03-20