English
Language : 

LPS-100 Datasheet, PDF (1/2 Pages) List of Unclassifed Manufacturers – 100W Single Output without PFC Function
100W Single Output without PFC Function
LPS-100 series
Features :
Universal AC input / Full range
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
100% full load burn-in test
Fix switching frequency at 134KHz
3 years warranty
SPECIFICATION
MODEL
LPS-100-3.3 LPS-100-5 LPS-100-7.5 LPS-100-12 LPS-100-13.5 LPS-100-15 LPS-100-24 LPS-100-27 LPS-100-48
DC VOLTAGE
3.3V
5V
7.5V
12V
13.5V
15V
24V
27V
48V
RATED CURRENT
20A
20A
13.3A
8.4A
7.5A
6.7A
4.2A
3.8A
2.1A
CURRENT RANGE
0 ~ 20A
0 ~ 20A
0 ~ 13.3A 0 ~ 8.4A 0 ~ 7.5A 0 ~ 6.7A 0 ~ 4.2A(6A 10s) 0 ~ 3.8A 0 ~ 2.1A
RATED POWER
66W
100W
99.75W
100.8W
101.25W 100.5W
100.8W(144W 10s) 102.6W
100.8W
RIPPLE & NOISE (max.) Note.2 150mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 150mVp-p 150mVp-p 200mVp-p
OUTPUT
VOLTAGE ADJ. RANGE
3 ~ 3.6V
VOLTAGE TOLERANCE Note.3 3.0%
LINE REGULATION
0.5%
4.5 ~ 5.7V
3.0%
0.5%
6 ~ 9V
2.0%
0.5%
10 ~ 13.2V
2.0%
0.5%
12 ~ 15V
2.0%
0.5%
13.5 ~ 18V
2.0%
0.5%
20 ~ 26.4V
1.0%
0.5%
26 ~ 32V
1.0%
0.5%
41 ~ 56V
1.0%
0.5%
LOAD REGULATION
SETUP, RISE TIME
2.0%
2.0%
1.5%
1.5%
1.5%
1.5%
0.5%
0.5%
0.5%
800ms, 50ms/230VAC 1200ms, 50ms/115VAC at full load
HOLD UP TIME (Typ.)
20ms/230VAC 20ms/115VAC at full load
VOLTAGE RANGE
88 ~ 132VAC / 176 ~ 264VAC auto switch 248 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
INPUT
EFFICIENCY(Typ.)
AC CURRENT (Typ.)
69%
77%
77%
79%
79%
80%
80%
81%
81%
2.3A/115VAC 1.5A/230VAC
INRUSH CURRENT (Typ.) COLD START 30A/115VAC 60A/230VAC
LEAKAGE CURRENT
<1mA / 240VAC
OVERLOAD
PROTECTION
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
105 ~ 140% (+24V: above 6.5A) rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
3.8 ~ 4.45V 5.75 ~ 6.75V 9.4 ~ 10.9V 13.8 ~ 16.2V 15.5 ~ 18.2V 18 ~ 21V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
-10 ~ +60 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
27.6 ~ 32.4V 33.7 ~ 39.2V 57.6 ~ 67.2V
ENVIRONMENT STORAGE TEMP., HUMIDITY -20 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.05%/ (0 ~ 50
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL60950-1, TUV EN60950-1 approved
SAFETY &
EMC
(Note 4)
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,11, light industry level, criteria A
OTHERS
NOTE
MTBF
203.6Khrs min. MIL-HDBK-217F (25 )
DIMENSION
222*62*32mm (L*W*H)
PACKING
0.45Kg; 24pcs/12.5Kg/1.39CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. If the input range 85V-89V, the output load is changed from 0A-rated load, There will be reduced 20V for 1second (LPS-100-24).
6. Mounting holes M1 and M2 should be grounded for EMI purposes.
File Name:LPS-100-SPEC 2008-03-25