English
Language : 

LPF-90_1108 Datasheet, PDF (1/3 Pages) Mean Well Enterprises Co., Ltd. – 90W Single Output Switching Power Supply
90W Single Output Switching Power Supply
LPF-90 series
Features :
Universal AC input / Full range (up to 305VAC)
Built-in active PFC function
High efficiency up to 91%
Protections: Short circuit / Over current / Over voltage / Over temperature
Cooling by free air convection
Fully isolated plastic case
Fully encapsulated with IP67 level (Note.6)
Class power unit, no FG
Suitable for LED lighting and moving sign applications
Compliance to worldwide safety regulations for lighting
Suitable for dry / damp / wet locations
3 years warranty
F 110 M M SELV IP67
( except for 48V,54V )
SPECIFICATION
MODEL
LPF-90-15 LPF-90-20 LPF-90-24 LPF-90-30 LPF-90-36 LPF-90-42 LPF-90-48 LPF-90-54
OUTPUT
DC VOLTAGE
15V
20V
24V
30V
36V
CONSTANT CURRENT REGION Note.4 9 ~ 15V
12 ~ 20V
14.4 ~ 24V 18 ~ 30V
21.6 ~ 36V
RATED CURRENT
5A
4.5A
3.75A
3A
2.5A
RATED POWER
75W
90W
90W
90W
90W
RIPPLE & NOISE (max.) Note.2 150mVp-p 150mVp-p 150mVp-p 200mVp-p 200mVp-p
VOLTAGE TOLERANCE Note.3 4.0%
4.0%
4.0%
4.0%
4.0%
LINE REGULATION
0.5%
0.5%
0.5%
0.5%
0.5%
LOAD REGULATION
1.5%
1.0%
0.5%
0.5%
0.5%
SETUP, RISE TIME Note.7 2000ms, 80ms / 115VAC at full load 1000ms, 80ms / 230VAC at full load
HOLD UP TIME (Typ.)
16ms/230VAC 16ms/115VAC at full load
42V
25.2 ~ 42V
2.15A
90.3W
200mVp-p
4.0%
0.5%
0.5%
48V
28.8 ~ 48V
1.88A
90.24W
200mVp-p
4.0%
0.5%
0.5%
54V
32.4 ~ 54V
1.67A
90.18W
200mVp-p
4.0%
0.5%
0.5%
INPUT
VOLTAGE RANGE Note.5 90 ~ 305VAC 127 ~ 431VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.97/115VAC, PF>0.96/230VAC, PF>0.95/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
EFFICIENCY (Typ.)
89%
90%
90.5%
91%
91%
91%
91%
91%
AC CURRENT (Typ.)
0.95A / 115VAC 0.5A / 230VAC 0.4A / 277VAC
INRUSH CURRENT(Typ.)
COLD START 70A/230VAC
LEAKAGE CURRENT
<0.75mA / 277VAC
OVER CURRENT
PROTECTION OVER VOLTAGE
95 ~ 108%
Note.4
Protection type : Constant current limiting, recovers automatically after fault condition is removed
18 ~ 21V
23 ~ 27V
28 ~ 34V
34 ~ 38V
41 ~ 46V
47 ~ 53V
Protection type : Shut down o/p voltage, re-power on to recover
54 ~ 60V
59 ~ 65V
OVER TEMPERATURE
90 10 (RTH2)
Protection type : Shut down o/p voltage, re-power on to recover
WORKING TEMP.
-40 ~ +70 (Refer to "Derating Curve")
WORKING HUMIDITY
20 ~ 95% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +80 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03%/ (0 ~ 50 )
VIBRATION
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY STANDARDS
UL8750, EN61347-1, EN61347-2-13 independent, J61347-1, J61347-2-13, IP67 approved ; Design refer to UL60950-1, TUV EN60950-1
WITHSTAND VOLTAGE
SAFETY &
ISOLATION RESISTANCE
EMC
EMC EMISSION
I/P-O/P:3.75KVAC
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55015, EN61000-3-2 Class C ( 60% load) ; EN61000-3-3
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, EN55024, light industry level(surge 2KV), criteria A
MTBF
301.6Khrs min. MIL-HDBK-217F (25 )
OTHERS DIMENSION
161*61*36mm (L*W*H)
PACKING
0.7Kg;20pcs/15Kg/0.73CUFT
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Constant current operation region is within 60% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
5. Derating may be needed under low input voltages. Please check the static characteristics for more details.
6. Suitable for indoor use or outdoor use without direct sunlight exposure. Please avoid immerse in the water over 30 minutes.
7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
File Name:LPF-90-SPEC 2011-08-12