English
Language : 

LPC-60 Datasheet, PDF (1/2 Pages) Mean Well Enterprises Co., Ltd. – 60W Single Output Switching Power Supply
60W Single Output Switching Power Supply
LPC-60 series
SPECIFICATION
Features :
Constant current design
Universal AC input / Full range
Epoxy encapsulated with IP67 level
Withstand 300VAC surge input for 5 seconds
Protections: Short circuit / Over current / Over voltage
Fully isolated plastic case
Cooling by free air convection
UL1310 Class 2 power unit, pass LPS
100% full load burn-in test
Low cost, high reliability
Suitable for LED lighting and moving sign applications
2 years warranty
LPS IP67
( except for 34V )
( for 34V only)
MODEL
LPC-60-1050
LPC-60-1400
LPC-60-1750
OUTPUT
DC VOLTAGE
48V
42V
DC VOLTAGE RANGE
9 ~ 48V
9 ~ 42V
CURRENT RANGE
1050mA
1400mA
RATED POWER
50.4W
58.8W
RIPPLE & NOISE (max.) Note.2 200mVp-p
200mVp-p
VOLTAGE TOLERANCE Note.3 5.0%
LINE REGULATION
1.0%
LOAD REGULATION
2.0%
SETUP, RISE TIME Note.6 500ms, 120ms / 230VAC 500ms, 120ms / 115VAC at full load
HOLD UP TIME (Typ.)
50ms/230VAC 16ms/115VAC at full load
34V
9 ~ 34V
1750mA
59.5W
200mVp-p
VOLTAGE RANGE
90 ~ 264VAC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.)
87%
85%
87%
INPUT
AC CURRENT
1.2A/115VAC 0.7A/230VAC
INRUSH CURRENT(max.) COLD STAR 30A/115VAC 60A/230VAC
LEAKAGE CURRENT
0.25mA / 240VAC
CURRENT LIMIT
PROTECTION
OVER VOLTAGE
5% rated output current
Note.4
Protection type : Constant current limiting type
50.4 ~ 60V
44.1 ~ 56.7V
Protection type : Shut off o/p voltage, clamping by TVS diode
39.1 ~ 45.9V
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
-30 ~ +70 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH
0.03%/ (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL1310 Class 2, CAN/CSA C22.2 No. 223-M91(for 34V only), IP67 approved, design refer to TUV EN60950-1, EN61347-2-13
WITHSTAND VOLTAGE
I/P-O/P:3KVAC
SAFETY & ISOLATION RESISTANCE I/P-O/P:>100M Ohms / 500VDC / 25 / 70% RH
EMC
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
MTBF
732Khrs min. MIL-HDBK-217F (25 )
OTHERS
NOTE
DIMENSION
162.5*42.5*32mm (L*W*H)
PACKING
0.4Kg; 32pcs/13.8Kg/0.56CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the derating curve for more details.
5. The power supply is considered a component which will be installed a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
File Name:LPC-60-SPEC 2008-12-11