English
Language : 

LPC-35_12 Datasheet, PDF (1/2 Pages) Mean Well Enterprises Co., Ltd. – 35W Single Output Switching Power Supply
35W Single Output Switching Power Supply
LPC-35 series
Features :
Constant current design
Universal AC input / Full range
Withstand 300VAC surge input for 5 seconds
Protections: Short circuit / Over voltage
Cooling by free air convection
Fully encapsulated with IP67 level (Note.8)
Fully isolated plastic case
Class power unit, no FG
Class 2 power unit
Pass LPS
Suitable for LED lighting and moving sign applications (Note.7)
100% full load burn-in test
Low cost, high reliability
2 years warranty
SPECIFICATION
LPS IP67
( for 700mA only)
( except for 700mA )
MODEL
LPC-35-700
LPC-35-1050
LPC-35-1400
OUTPUT
RATED CURRENT
700mA
1050mA
DC VOLTAGE RANGE
9 ~ 48V
9 ~ 30V
RATED POWER
33.6W
31.5W
RIPPLE & NOISE (max.) Note.2 200mVp-p
200mVp-p
VOLTAGE TOLERANCE Note.3 5.0%
CURRENT ACCURACY
5.0%
LINE REGULATION
1.0%
LOAD REGULATION
2.0%
SETUP, RISE TIME Note.6 500ms, 120ms / 230VAC 500ms, 120ms / 115VAC at full load
HOLD UP TIME (Typ.)
50ms/230VAC 16ms/115VAC at full load
1400mA
9 ~ 24V
33.6W
200mVp-p
INPUT
VOLTAGE RANGE
Note.4 90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.)
85%
AC CURRENT (Typ.)
1.1A/115VAC 0.7A/230VAC
INRUSH CURRENT(max.) COLD START 30A/115VAC 60A/230VAC
LEAKAGE CURRENT
0.25mA / 240VAC
PROTECTION OVER VOLTAGE
50.4 ~ 60V
31.5 ~ 40.5V
Protection type : Shut off o/p voltage, clamping by zener diode
27.6 ~ 32.4V
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
-30 ~ +75 (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH
0.03%/ (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL1310, CAN/CSA C22.2 No. 223-M91(except for LPC-35-700), IP67 approved ; design refer to TUV EN60950-1
WITHSTAND VOLTAGE
SAFETY &
EMC
ISOLATION RESISTANCE
EMC EMISSION
EMC IMMUNITY
MTBF
I/P-O/P:3KVAC
I/P-O/P:>100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2 Class A, EN61000-3-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A
743.5Khrs min. MIL-HDBK-217F (25 )
OTHERS
NOTE
DIMENSION
148*40*30mm (L*W*H)
PACKING
0.34Kg; 40pcs/14.6Kg/0.63CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. The unit might not be suitable for lighting applications in EU countries. Please check with your local authorities for the possible use of the unit.
8. Suitable for indoor use or outdoor use without direct sunlight exposure. Please avoid immerse in the water over 30 minute.
File Name:LPC-35-SPEC 2012-03-20