LCM-40 Datasheet, PDF (1/5 Pages) Mean Well Enterprises Co., Ltd. – 40W Multiple-Stage Output Current LED Power Supply
40W Multiple-Stage Output Current LED Power Supply
LCM-40 series
¡½ Features :
¡EOutput current level selectable by DIP S.W.
¡E180~295VAC input only
¡EBuilt-in active PFC function
¡EProtections: Short circuit / Over voltage / Over temperature
¡ECooling by free air convection
¡EFully isolated plastic case
¡E ¢º Class power unit, no FG
¡EBuilt-in 0~10Vdc and PWM signal dimming function
¡EBuilt-in 12V/50mA auxiliary output
¡EIP20 design
¡ETemperature compensation function by external NTC
¡ENo load power consumption <1W@AC always on (Note 8)
¡EPower supplies synchronization function up to 10 units
¡ESuitable for LED lighting applications
¡E3 years warranty
SPECIFICATION
F 110 M M
SELV
MODEL
LCM-40
SELECTABLE CURRENT Note.3 350mA
DC VOLTAGE RANGE
2 ~ 100V
RATED POWER
42W
500mA
2 ~ 80V
600mA
2 ~ 67V
700mA
2 ~ 57V
900mA
2 ~ 45V
1050mA
2 ~ 40V
RIPPLE CURRENT
200mVp-p
OUTPUT RIPPLE & NOISE (max.) Note.2 700mVp-p
NO LOAD OUTPUT VOLTAGE (max.) 110V
65V
CURRENT ACCURACY
¡Ó5.0%
SETUP, RISE TIME Note.6 1000ms, 80ms / 230VAC at rated power
HOLD UP TIME (Typ.)
16ms/230VAC at rated power
INPUT
VOLTAGE RANGE Note.4 180 ~ 295VAC 254 ~ 417VDC
FREQUENCY RANGE
POWER FACTOR (Typ.)
47 ~ 63Hz
¡Ù ¡Ù PF 0.98/230VAC, PF 0.97/277VAC at rated power (Please refer to "Power Factor Characteristic" curve)
TOTAL HARMONIC DISTORTION Total harmonic distortion will be lower than 20% when output loading is 75% or higher
EFFICIENCY (Typ.) Note.7 91%
AC CURRENT (Typ.)
0.21A/230VAC 0.17A/277VAC
INRUSH CURRENT(Typ.)
COLD START 35A/230VAC
LEAKAGE CURRENT
SHORT CIRCUIT
OVER VOLTAGE
PROTECTION
OVER TEMPERATURE
AUXILIARY POWER
TEMP. COMPENSATION
FUNCTION DIMMING
SYNCHRONIZATION
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
<0.5mA / 240VAC
Constant current limiting, recovers automatically after fault condition is removed
110 ~ 130V
Protection type : Shutdown o/p voltage, re-power on to recover
90¢J¡Ó10¢J (RTH2)
Protection type : Shut down o/p voltage, re-power on to recover
¡Ó 12V @ 50mA for driving fan; Tolerance 5%
By external NTC(not provide with the power supply), please see "Temperature Compensation Operation"
Please see "Dimming Operation"
Please see "Synchronization Operation"
¢J -30 ~ +60 (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
¢J -40 ~ +80 , 10 ~ 95% RH
¡Ó ¢J ¢J 0.03%/ (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS
WITHSTAND VOLTAGE
SAFETY &
ISOLATION RESISTANCE
EMC
EMC EMISSION
EMC IMMUNITY
MTBF
UL8750, ENEC EN61347-1, EN61347-2-13,EN62384 independent approved
I/P-O/P:3.75KVAC
¢J I/P-O/P:>100M Ohms / 500VDC / 25 / 70% RH
¡Ù Compliance to EN55015, EN61000-3-2 Class C( 35% rated power) ; EN61000-3-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61547 light industry level (surge 2KV), criteria A
¢J K hrs min. MIL-HDBK-217F (25 )
OTHERS
NOTE
DIMENSION
123.5*81.5*23mm (L*W*H)
¢J PACKING
0.24Kg
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf parallel capacitor.
3. Please see "DIP switch table".
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. Efficiency is measured at 500mA/80V output set by DIP switch.
8. No load power consumption<1W is measured at 180~277VAC.
File Name:LCM-40-SPEC 2012-09-11