English
Language : 

ISI-500_1109 Datasheet, PDF (1/2 Pages) Mean Well Enterprises Co., Ltd. – Modified Sine Wave DC-AC Inverter with MPPT Solar Charger
I S I - 5 0 0 Modified Sine Wave DC-AC Inverter with MPPT Solar Charger
series
SPECIFICATION
Features :
High surge power up to 1000W
Power ON-OFF switch
Protections: Bat. low alarm / Bat. low shutdown / Over temp.
/ Output short / Input polarity reverse / Over load
High frequecny design
AC Output voltage regulation : 10%
AC Output wavform : Modified sine wave
Modified models available(optional): 100/115/120VAC or 200/220/240VAC
Cooling fan ON-OFF control
Built-in 500W MPPT solar charger, MPPT efficiency: 98%(Typ.)
Built-in battery low relay contact
LED indicator for operation status
2 years warranty
MODEL
ISI-500-112
ISI-500-124
ISI-500-148
ISI-500-212
ISI-500-224
ISI-500-248
RATED POWER
350W
500W
500W
350W
500W
500W
MAXIMUM OUTPUT POWER (Typ.) 550W for 1 minute / surge power 1000W for 30 cycles (112, 212 models : 385W for 1 minute / surge power 700W for 30 cycles)
WAVEFORM
Modified sine wave
OUTPUT AC VOLTAGE
110V
230V
FREQUENCY
60Hz 0.5Hz
50Hz 0.5Hz
AC REGULATION
10%
LED INDICATOR
Green: Inverter OK Green (flashing): Inverter OK and charging Red: abnormal
BAT. VOLTAGE
12V
24V
48V
12V
24V
48V
VOLTAGE RANGE Note.3,4 10.5 ~ 15VDC
21 ~ 30VDC
42 ~ 60VDC
10.5 ~ 15VDC
21 ~ 30VDC
42 ~ 60VDC
DC CURRENT (Typ.)
35A
25A
12.5A
35A
25A
12.5A
INPUT
NO LOAD CURRENT DRAW 0.8A
0.4A
0.2A
0.8A
0.4A
0.2A
OFF MODE CURRENT DRAW 1mA
EFFICIENCY (Typ.) Note.1 85%
87%
87%
86%
88%
88%
BATTERY TYPE
Open & sealed Lead Acid
SOLAR
PANEL
INPUT
VOLTAGE RANGE
20 ~ 40V
MAX. SHORT CIRCUIT CURRENT 15A
RATED CHARGE POWER (Typ.) 350W
35 ~ 80V
15A
500W
70 ~ 160V
7.5A
500W
20 ~ 40V
15A
350W
35 ~ 80V
15A
500W
70 ~ 160V
7.5A
500W
SOLAR MAX. CHARGE VOLTAGE 14V
28V
56V
14V
28V
56V
CHARGER MAX. CHARGE CURRENT 25A
20A
10A
25A
20A
10A
CHARGER MAX. CHARGING VOLTAGE 14V
28V
56V
14V
28V
56V
OUTPUT MAX. CHARGING CURRENT 25A
20A
10A
25A
20A
10A
FUSE
40A
30A
15A
40A
30A
15A
BATTERY BAT. LOW ALARM
Note.4 11V
22V
44V
11V
22V
44V
INPUT
PROTECTION BAT. LOW SHUTDOWN Note.4 10.5V
21V
42V
10.5V
21V
42V
REVERSE POLARITY
By internal fuse
OVER TEMPERATURE
OUTPUT
PROTECTION OUTPUT SHORT
70 10
65 10
Protection type : Shut down o/p voltage, re-power on to recover ; by internal RTH9 detect on power transistor
Protection type : Shut down o/p voltage, re-power on to recover
OVER LOAD
Protection type : Shut down o/p voltage, re-power on to recover ; >105% load @ 60 sec.
FUNCTION BAT. LOW RELAY CONTACT Open : Battery low ; Short : Battery ok
WORKING TEMP.
Note.2 -20 ~ +40 @ 100% load ; 60 @ 50% load
WORKING HUMIDITY
20% ~ 90% RH non-condensing
ENVIRONMENT
STORAGE TEMP., HUMIDITY -30 ~ +70 / -22 ~ +158oF, 10 ~ 95% RH
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
LVD
None
EN60950-1
WITHSTAND VOLTAGE
Bat. I/P - AC O/P:3.0KVAC AC O/P - FG:1.5KVAC
EMC
ISOLATION RESISTANCE Bat. I/P-AC O/P, Bat. I/P-FG, AC O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
EMC EMISSION
Compliance to FCC part 15 class A
Compliance to EN55022 class A
EMS IMMUNITY
None
Compliance to EN61000-4-2,3,8
MTBF
81.1K hrs min. MIL-HDBK-217F (25oC)
OTHERS DIMENSION
205*158*67mm (L*W*H)
PACKING
1.92Kg; 6pcs/12.5Kg/1.55CUFT
NOTE
1.Efficiency is tested by 350W, linear load at 13V, 26V, 52V input voltage.
2.Output derating capacity referenced by curve 1.
3.Output derating capacity referenced by curve 2.
4.The tolerance of each voltage value by models is:112/212 0.5V;124/224 1V;148/248 2V.
5.All parameters not specified above are measured at rated load, 25 of ambient temperature.
File Name:ISI-500-SPEC 2011-09-22