English
Language : 

ISI-500 Datasheet, PDF (1/2 Pages) Mean Well Enterprises Co., Ltd. – Modified Sine Wave DC-AC Inverter with MPPT Solar Charger
I S I - 5 0 0 Modified Sine Wave DC-AC Inverter with MPPT Solar Charger
series
Features :
Power ON-OFF switch
Protections: Bat. low alarm / Bat. low shutdown / Over temp.
/ Output short / Input polarity reverse / Over load
High frequecny design
Output voltage regulation : 10%
High surge power up to 1000W
Output wavform : Modified sine wave
Modified models available: 110/115/120VAC or 220/220/240VAC
Cooling fan ON-OFF control
Built-in MPPT solar charger
Built-in battery low relay contact
LED indicator for operation status
SPECIFICATION
2 years warranty
MODEL
ISI-500-112
ISI-500-124
ISI-500-148
ISI-500-212
ISI-500-224
ISI-500-248
RATED POWER
Note.2 350W
500W
SURGE POWER (Typ.)
700W
1000W
WAVEFORM
Modified sine wave
500W
1000W
350W
700W
500W
1000W
500W
1000W
OUTPUT AC VOLTAGE
110V
230V
FREQUENCY
60Hz 0.5Hz
50Hz 0.5Hz
AC REGULATION
10%
LED INDICATOR
Green: Inverter OK, Green (flashing): Inverter OK and charging, Red: abnormal
BAT. VOLTAGE
12V
24V
48V
12V
24V
48V
INPUT
VOLTAGE RANGE Note.3 10.5 ~ 15VDC
DC CURRENT (Typ.)
35A
NO LOAD CURRENT DRAW 0.8A
OFF MODE CURRENT DRAW 1mA
21 ~ 30VDC
25A
0.4A
42 ~ 60VDC
12.5A
0.2A
10.5 ~ 15VDC
35A
0.8A
21 ~ 30VDC
25A
0.4A
42 ~ 60VDC
12.5A
0.2A
EFFICIENCY (Typ.) Note.1 85%
87%
87%
86%
88%
88%
BATTERY TYPE
Open & sealed Lead Acid
SOLAR
PANEL
INPUT
VOLTAGE RANGE
20 ~ 40V
MAX. SHORT CIRCUIT CURRENT 15A
RATED CHARGE POWER (Typ.) 350W
35 ~ 80V
15A
500W
70 ~ 160V
7.5A
500W
20 ~ 40V
15A
350W
35 ~ 80V
15A
500W
70 ~ 160V
7.5A
500W
FUSE
40A
30A
15A
40A
30A
15A
BATTERY BAT. LOW ALARM
Note.3 11V
22V
44V
11V
22V
44V
INPUT
PROTECTION BAT. LOW SHUTDOWN Note.3 10.5V
21V
42V
10.5V
21V
42V
REVERSE POLARITY
By internal fuse
OVER TEMPERATURE
OUTPUT
PROTECTION OUTPUT SHORT
55 10
65 10
55 10
50 10
70 10
Protection type : Shut down o/p voltage, re-power on to recover ; by internal RTH9 detect power transistor
Protection type : Shut down o/p voltage, re-power on to recover
50 10
OVER LOAD
Protection type : Shut down o/p voltage, re-power on to recover ; >105% load @ 60 sec.
FUNCTION BAT. LOW RELAY CONTACT
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT
STORAGE TEMP., HUMIDITY
Open : Battery low ; Short : Battery ok
-20 ~ +40 @ 100% load ; 60 @ 50% load
20% ~ 90% RH non-condensing
-30 ~ +70 / -22 ~ +158oF, 10 ~ 95% RH
EMC
OTHERS
VIBRATION
LVD
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC EMISSION
EMS IMMUNITY
MTBF
DIMENSION
PACKING
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
None
EN60950-1
Bat. I/P - AC O/P:3.0KVAC AC O/P - FG:1.5KVAC
Bat. I/P-AC O/P, Bat. I/P-FG, AC O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to FCC class A
Compliance to EN55022 class A, 72/ 245/ CEE, 95/ 54/ CE
None
Compliance to EN61000-4-2,3,8
81.1K hrs min. MIL-HDBK-217F (25oC)
205*158*67mm (L*W*H)
1.92Kg; 6pcs/12.5Kg/1.55CUFT
NOTE
1.Efficiency is tested by 350W, linear load at 13V, 26V, 52V input voltage.
2.Output derating capacity referenced by curve 1.
3.The tolerance of each voltage value by models is:112/212 0.5V;124/224 1V;148/248 2V.
4.All parameters not specified above are measured at rated load, 25 of ambient temperature.
File Name:ISI-500-SPEC 2011-05-31