English
Language : 

IPC-300A_10 Datasheet, PDF (1/6 Pages) Mean Well Enterprises Co., Ltd. – 300W Industrial 1U ATX 12V/P4 PC Power Supply
300W Industrial 1U ATX 12V/P4 PC Power Supply
IPC-300A
Features :
Meet 1U rack mount system
Universal AC input / Full range
Active power factor 94%
Protections:Short circuit / Overload / Over voltage
Forced air cooling by built-in DC fan
With power good and fail signal output
Built-in remote ON-OFF control
Remote DC sense +5V and +3.3V
With +5VSB:0 ~ 2.0A max.
100% full load burn-in test
High efficiency
SPECIFICATION
2 years warranty
MODEL
IPC-300A
OUTPUT NUMBER
CH1
CH2
CH3
CH4
CH5
STANDBY
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
3.3V
20A
0 ~ 20A
5V
30A
1 ~ 30A
12V
18A
1 ~ 18A
-5V
0.5A
0 ~ 0.5A
-12V
1A
0.1 ~ 1A
5VSB
2A
0 ~ 2A
RATED POWER
300W continue. +5V,+3.3V,+12V combine total power output shall not exceed 270W.(The +5 & +3.3Volt combine total output shall not exceed 150W)
(The -5 & -12Volt combine total output shall not exceed 12W)
OUTPUT
RIPPLE & NOISE (max.) Note.2 50mVp-p
VOLTAGE ADJ. RANGE
CH2 : 5.05 ~ 5.5V
VOLTAGE TOLERANCE Note.3 5.0%
LINE REGULATION
1.0%
50mVp-p
5.0%
1.0%
120mVp-p
7.0%
1.0%
100mVp-p
8.0%
2.0%
120mVp-p
10%
2.0%
50mVp-p
5.0%
1.0%
LOAD REGULATION
5.0%
5.0%
7.0%
8.0%
10%
5.0%
SETUP, RISE TIME
HOLD TIME (Typ.)
800ms, 20ms/230VAC 2500ms, 20ms/115VAC at full load
16ms/230VAC 16ms/115VAC at full load
VOLTAGE RANGE
90 ~ 264VAC
FREQUENCY RANGE
47 ~ 63Hz
INPUT
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT(max.)
OVER LOAD
75%
4.6A/115VAC 2.3A/230VAC
40A/115VAC 80A/230VAC
3mA/240VAC
105 ~ 150% rated output power
Protection type : Shut down o/p voltage, re-power on to recover
PROTECTION OVER VOLTAGE
+3.3V, +5V: 110% ~ 140% of rated voltage ; +12V:13.2V ~ 16V
Protection type : Shut down o/p voltage, re-power on to recover
SHORT CIRCUIT
All output equipped with short circuit
Protection type : Shut down o/p voltage, re-power on to recover
POWER GOOD SIGNAL
FUNCTION POWER FAIL SIGNAL
PS-ON INPUT SIGNAL
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
The TTL compatible signal out with 100ms to 500ms delay after power set up
The TTL compatible signal will go down at least 1ms before +5V below 4.75V
Power off: PS-ON = "Hi" or ">2V" ; Power on: PS-ON = "Low" or "<0.5V"
-10 ~ +60 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-40 ~ +85 10 ~ 95% RH
0.05% / (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
I/P-O/P:1.5KVAC I/P-FG:1.5KVAC
SAFETY &
EMC
(Note 4)
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:50M Ohms / 500VDC / 25 / 70% RH
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B, Design refer to FCC part 15 Class B
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
EMS IMMUNITY
Compliance to EN61000-4-2,3,4, 5,6,8,11, light industry level, criteria A
MTBF
94.1K hrs min. MIL-HDBK-217F (25 )
OTHERS
CONNECTOR
COOLING
DIMENSION
PACKING
ATX main power connector * 1ea; +12V power connector * 1ea
Peripheral power connector * 3ea; Floppy drive power connector * 1ea
Forced air ventilation by 4cm DC fan
260*83*40mm (L*W*H)
1.46Kg; 10pcs/15.6Kg/0.89CUFT
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Load regulation is measured from 20% to 100% max. Load.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
File Name: IPC-300A-SPEC 2010-10-18