English
Language : 

IPC-200_1112 Datasheet, PDF (1/3 Pages) Mean Well Enterprises Co., Ltd. – 200W Industrial 1U ATX 12V/P4 PC Power Supply
200W Industrial 1U ATX 12V/P4 PC Power Supply
IPC-200
Features :
Meet 1U rack mount system
Universal AC input / Full range
Active power factor 94%
Protections:Short circuit/Overload/Over voltage
Forced air cooling by built-in DC fan
With power good and fail signal output
Built-in remote ON-OFF control
Remote DC sense +5V and +3.3V
With +5VSB:0 ~ 2.0A max.
100% full load burn-in test
High efficiency
SPECIFICATION
2 years warranty
MODEL
IPC-200
OUTPUT NUMBER
CH1
CH2
CH3
CH4
CH5
STANDBY
DC VOLTAGE
3.3V
5V
12V
-5V
-12V
5VSB
RATED CURRENT
15A
25A
13A
0.5A
1A
2A
CURRENT RANGE
0 ~ 15A
1 ~ 25A
1 ~ 13A
0 ~ 0.5A
0.1 ~ 1A
0 ~ 2A
RATED POWER
200W continue. Combine power max.:+5V,+3.3V,+12V output shall not exceed 180W max. (The +5 & +3.3Volt combine total output shall not exceed 150W)
(The -5 & -12Volt combine total output shall not exceed 12W)
OUTPUT RIPPLE & NOISE (max.) Note.2 50mVp-p
50mVp-p
120mVp-p
100mVp-p
120mVp-p
50mVp-p
VOLTAGE ADJ. RANGE
CH2 : 5.05 ~ 5.5V
VOLTAGE TOLERANCE Note.3 CH1: 5.0%
5.0%
7.0%
8.0%
10%
5.0%
LINE REGULATION
1.0%
1.0%
1.0%
2.0%
2.0%
1.0%
LOAD REGULATION
5.0%
5.0%
7.0%
8.0%
10%
5.0%
SETUP, RISE TIME
800ms, 20ms/230VAC 2500ms, 20ms/115VAC at full load
HOLD TIME (Typ.)
16ms/230VAC 16ms/115VAC at full load
VOLTAGE RANGE
90 ~ 264VAC
FREQUENCY RANGE
47 ~ 63Hz
INPUT
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
74.5%
3.5A/115VAC 1.7A/230VAC
INRUSH CURRENT (Typ.)
40A/115VAC 80A/230VAC
LEAKAGE CURRENT(max.) 3mA/240VAC
OVER LOAD
105 ~ 150% rated output power
Protection type : Shut down o/p voltage, re-power on to recover
PROTECTION OVER VOLTAGE
+3.3V, +5V: 110% ~ 140% of rated voltage ; +12V:13.2V ~ 16V
Protection type : Shut down o/p voltage, re-power on to recover
SHORT CIRCUIT
All output equipped with short circuit
Protection type : Shut down o/p voltage, re-power on to recover
POWER GOOD SIGNAL
FUNCTION POWER FAIL SIGNAL
The TTL compatible signal out with 100ms to 500ms delay after power set up
The TTL compatible signal will go down at least 1ms before +5V below 4.75V
PS-ON INPUT SIGNAL
Power off: PS-ON = "Hi" or ">2V" ; Power on: PS-ON = "Low" or "<0.5V"
WORKING TEMP.
-10 ~ +60 (Refer to "Derating Curve")
WORKING HUMIDITY
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85 10 ~ 95% RH
TEMP. COEFFICIENT
0.05% / (0 ~ 50 )
VIBRATION
SAFETY STANDARDS
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
SAFETY & WITHSTAND VOLTAGE
I/P-O/P:1.5KVAC I/P-FG:1.5KVAC
EMC
(Note 4)
ISOLATION RESISTANCE
EMC EMISSION
I/P-O/P, I/P-FG, O/P-FG:50M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B, Design refer to FCC part 15 Class B, EN61000-3-2,-3
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2 (EN50082-2), heavy industry level, criteria A
MTBF
94.1K hrs min. MIL-HDBK-217F (25 )
OTHERS
CONNECTOR
COOLING
ATX main power connector * 1ea; +12V power connector * 1ea
Peripheral power connector * 3ea; Floppy drive power connector * 1ea
Forced air ventilation by 4cm DC fan
DIMENSION
240*83*40mm (L*W*H)
PACKING
1.44Kg; 10pcs/15.4Kg/0.89CUFT
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Load regulation is measured from 20% to 100% max. Load.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
File Name: IPC-200-SPEC 2011-12-20