English
Language : 

ID-50 Datasheet, PDF (1/2 Pages) Mean Well Enterprises Co., Ltd. – 50W Isolated Dual Output Switching Power Supply
50W Isolated Dual Output Switching Power Supply
ID-50 series
Features :
Isolated output & GND for CH1,CH2
Universal AC input/Full range
Protections:Short circuit/Overload/Over voltage
Cooling by free air convection
100% full load burn-in test
Fixed switching frequency at 50KHz
Low cost
High reliability
1 year warranty
SPECIFICATION
MODEL
ID-50A
ID-50B
ID-50C
ID-50D
OUTPUT
CH1
CH2
CH1
CH2
CH1
CH2
CH1
CH2
DC VOLTAGE
5V
5V
13.5V
13.5V
27V
27V
5V
13.5V
RATED CURRENT
6A
2A
1.8A
1.8A
0.9A
0.9A
5A
1.7A
CURRENT RANGE
0.5 ~ 6A
0 ~ 2A
0.3 ~ 2A
0 ~ 2A
0.18 ~ 1A
0 ~ 1A
1 ~ 5A
0 ~ 2A
OUTPUT
RATED POWER
40W
RIPPLE & NOISE (max.) Note.2 50mVp-p
100mVp-p
VOLTAGE ADJ. RANGE
CH1,2 : 4.75 ~ 5.5V
VOLTAGE TOLERANCE Note.3 1.0%
2.0%
LINE REGULATION
0.5%
0.5%
48.6W
100mVp-p 150mVp-p
CH1,2 : 12 ~ 15V
1.0%
2.0%
0.5%
0.5%
48.6W
100mVp-p 150mVp-p
CH1,2 : 24 ~ 30V
1.0%
2.0%
0.3%
0.5%
48W
50mVp-p
150mVp-p
CH1 : 4.75 ~ 5.5V
1.0%
2.0%
0.5%
0.5%
LOAD REGULATION
0.5%
1.0%
0.5%
1.0%
0.3%
1.0%
0.5%
1.0%
SETUP, RISE TIME
1600ms, 50ms at full load
HOLD TIME (Typ.)
VOLTAGE RANGE
100ms at full load
85 ~ 264VAC 120 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
INPUT
EFFICIENCY(Typ.)
66%
70%
72%
68%
AC CURRENT (Typ.)
1A/115VAC 0.6A/230VAC
INRUSH CURRENT (Typ.) COLD START 22A/115VAC 45A/230VAC
LEAKAGE CURRENT
<3.5mA / 240VAC
OVER LOAD
PROTECTION
OVER VOLTAGE
105 ~ 150%/115VAC rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
5V: 6.4 ~ 7.5V
13.5V:17 ~ 21V
27V:32 ~ 40V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
5V:6.4 ~ 7.5V
WORKING TEMP.
-10 ~ +60 (Refer to output load derating curve)
WORKING HUMIDITY
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -20 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03%/ (0 ~ 50 )on +5V output
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS
Design refer to UL1012
SAFETY & WITHSTAND VOLTAGE
I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
EMC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMI CONDUCTION & RADIATION Design refer to FCC Part15
MTBF
312.2K hrs min. MIL-HDBK-217F (25 )
OTHERS DIMENSION
159*97*38mm (L*W*H)
PACKING
0.54Kg; 24pcs/13.8Kg/0.75CUFT
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
File Name:ID-50-SPEC 2007-08-30