SPECIFICATION
MODEL
ID-30B
OUTPUT NUMBER
CH1
CH2
DC VOLTAGE
5V
24V
RATED CURRENT
2.2A
1A
CURRENT RANGE
0.1 ~ 2.2A
0.1 ~ 1A
OUTPUT
RATED POWER
35W
RIPPLE & NOISE (max.) Note.2 100mVp-p
VOLTAGE ADJ. RANGE
CH1 : 4.6 ~ 5.5V
VOLTAGE TOLERANCE Note.3 2.0%
LINE REGULATION
0.5%
150mVp-p
7.0%
0.5%
LOAD REGULATION
1.5%
6.5%
SETUP, RISE TIME
250ms, 100ms at full load
HOLD TIME (Typ.)
40ms at full load
VOLTAGE RANGE
90 ~ 130VAC / 180 ~ 260VAC selected by switch on PCB
FREQUENCY RANGE
47 ~ 63Hz
INPUT
EFFICIENCY(Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
72%
0.8A/110VAC
15A/110VAC
0.4A/220VAC
30A/220VAC
PROTECTION OVER LOAD
105 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
WORKING TEMP.
-10 ~ +60 (Refer to output load derating curve)
WORKING HUMIDITY
20 ~ 90% RH RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -20 ~ +85 , 10 ~ 95%
TEMP. COEFFICIENT
0.05%/
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS
Design refer to UL1012
SAFETY & WITHSTAND VOLTAGE
I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
EMC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMI CONDUCTION & RADIATION Design refer to FCC Part15 J Conduction Class A
MTBF
597.7K hrs min. MIL-HDBK-217F (25 )
OTHERS DIMENSION
129*98*38mm (L*W*H)
PACKING
0.41Kg; 30pcs/13.4Kg/0.86CUFT
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
File Name:ID-30B-SPEC 2006-08-01