English
Language : 

HSG-70 Datasheet, PDF (1/3 Pages) Mean Well Enterprises Co., Ltd. – 70W Single Output Switching Power Supply
70W Single Output Switching Power Supply
HSG-70 series
Features :
Universal AC input / Full range(up to 305VAC)
Protections:Short circuit/Over load/Over voltage/Over temperature
Built-in active PFC function
High efficiency up to 90%
Cooling by free air convection
IP65 design for indoor and outdoor installations
Small and compact size
High reliability,low cost
Suitable for LED lighting and moving sign applications
3 years warranty
SPECIFICATION
IP65
MODEL
HSG-70-12
HSG-70-18
HSG-70-24
HSG-70-36
HSG-70-48
DC VOLTAGE
12V
18V
24V
36V
48V
CONSTANT CURRENT REGION Note.5 7.7 ~ 12V
11.3 ~ 18V
15.5 ~ 24V
22.1 ~ 36V
29.3 ~ 48V
RATED CURRENT
5.0A
4.0A
3.0A
2.0A
1.5A
RATED POWER
60W
72W
72W
72W
72W
OUTPUT
CURRENT ADJ. RANGE
Can be adjusted by internal potentiometer
3 ~ 5A
2.4 ~ 4A
RIPPLE & NOISE (max.) Note.2 150mVp-p
200mVp-p
1.8 ~ 3A
200mVp-p
1.2 ~ 2A
200mVp-p
0.9 ~ 1.5A
200mVp-p
VOLTAGE TOLERANCE Note.3 2.5%
2.0%
1.0%
1.0%
1.0%
LINE REGULATION
0.5%
0.5%
0.5%
0.5%
0.5%
LOAD REGULATION
2.0%
1.5%
0.5%
0.5%
0.5%
SETUP, RISE TIME Note.7 2000ms,80ms / 115VAC 1000ms,80ms / 230VAC at full load
HOLD UP TIME
16ms at full load 230VAC/115VAC
VOLTAGE RANGE Note.4 90 ~ 305VAC 127~431VDC
INPUT
FREQUENCY RANGE
POWER FACTOR(Typ.)
EFFICIENCY(Typ.)
47 ~ 63Hz
PF 0.96/115VAC, PF 0.96/230VAC,PF>0.92/277VAC at full load(please refer to "Power Factor characteristic curve")
88%
89%
89%
90%
90%
AC CURRENT
0.85A/115VAC 0.425A/230VAC 0.4A/277VAC
INRUSH CURRENT(Typ.)
Cold start 70A/230VAC
LEAKAGE CURRENT
<0.75mA / 277VAC
OVER CURRENT Note.5
95 ~ 108%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
SHORT CIRCUIT
Protection type : Hiccup mode, recovers automatically after fault condition is removed.
PROTECTION OVER VOLTAGE
14 ~ 17V
21 ~ 25V
28 ~ 34V
Protection type : Shut down o/p voltage, re-power on to recover
41 ~ 48V
54 ~ 63V
OVER TEMPERATURE
100 10 (RTH2)
Protection type : Shut down o/p voltage, re-power on to recover
WORKING TEMP.
-40 ~ +70 (Refer to "Derating Curve")
WORKING HUMIDITY
20 ~ 95% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +80 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03%/ (0 ~ 50 )
VIBRATION
SAFETY STANDARDS
10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
IP65 approved; design refer to TUV EN61347-1, EN61347-2-13, UL8750
SAFETY & WITHSTAND VOLTAGE
EMC
ISOLATION RESISTANCE
EMC EMISSION
I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC / 25 / 70%RH
Compliance to EN55015,EN61000-3-2 Class C( 65% load);EN61000-3-3
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, EN55024, light industry level (surge 4KV), criteria A
MTBF
338.2Khrs min. MIL-HDBK-217F (25 )
OTHERS DIMENSION
127.2*90*38.8mm (L*W*H)
PACKING
0.76Kg;16pcs/ 12.3Kg/0.57CUFT
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage, please check the static characteristics for more details.
5. Constant current operation region is within 65% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
6. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
File Name:HSG-70-SPEC 2012-03-07