English
Language : 

HRPG-450 Datasheet, PDF (1/3 Pages) Mean Well Enterprises Co., Ltd. – 450W Single Output with PFC Function
450W Single Output with PFC Function
HRPG-450 series
Features :
Universal AC input / Full range
Built-in active PFC function, PF>0.95
High efficiency up to 89.5%
Withstand 300VAC surge input for 5 seconds
Protections: Short circuit / Overload / Over voltage / Over temperature
Built-in constant current limiting circuit
Built-in cooling Fan ON-OFF control
Built-in DC OK signal
Built-in remote ON-OFF control
Stand by 5V@0.3A
Built-in remote sense function
No load power consumption<0.5W (Note.7)
5 years warranty
SPECIFICATION
MODEL
HRPG-450-3.3 HRPG-450-5 HRPG-450-7.5 HRPG-450-12 HRPG-450-15 HRPG-450-24 HRPG-450-36 HRPG-450-48
OUTPUT
INPUT
DC VOLTAGE
3.3V
5V
7.5V
12V
15V
RATED CURRENT
90A
90A
60A
37.5A
30A
CURRENT RANGE
0 ~ 90A
0 ~ 90A
0 ~ 60A
0 ~ 37.5A
0 ~ 30A
RATED POWER
297W
450W
450W
450W
450W
RIPPLE & NOISE (max.) Note.2 80mVp-p
80mVp-p
100mVp-p 120mVp-p 150mVp-p
VOLTAGE ADJ. RANGE
2.8 ~ 3.8V 4.3 ~ 5.8V 6.8 ~ 9V
10.2 ~ 13.8V 13.5 ~ 18V
VOLTAGE TOLERANCE Note.3 2.0%
2.0%
2.0%
1.0%
1.0%
LINE REGULATION
0.5%
0.5%
0.5%
0.3%
0.3%
LOAD REGULATION
1.0%
1.0%
1.0%
0.5%
0.5%
SETUP, RISE TIME
1000ms, 100ms/230VAC 2500ms, 100ms/115VAC at full load
HOLD UP TIME (Typ.)
16ms/230VAC 16ms/115VAC at full load
VOLTAGE RANGE Note.5 85 ~ 264VAC 120 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.95/230VAC PF>0.99/115VAC at full load
EFFICIENCY (Typ.)
80%
83%
86.5%
88%
89%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
5A/115VAC 2.4A/230VAC
35A/115VAC 70A/230VAC
LEAKAGE CURRENT
<1.5mA / 240VAC
24V
18.8A
0 ~ 18.8A
451.2W
150mVp-p
21.6 ~ 28.8V
1.0%
0.2%
0.5%
36V
12.5A
0 ~ 12.5A
450W
240mVp-p
28.8 ~ 39.6V
1.0%
0.2%
0.5%
48V
9.5A
0 ~ 9.5A
456W
240mVp-p
40.8 ~ 55.2V
1.0%
0.2%
0.5%
88%
89%
89.5%
OVERLOAD
PROTECTION OVER VOLTAGE
105 ~ 135% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
3.96 ~ 4.62V 6 ~ 7V
9.4 ~ 10.9V 14.4 ~ 16.8V 18.8 ~ 21.8V 30 ~ 34.8V
Protection type : Shut down o/p voltage, re-power on to recover
41.4 ~ 48.6V
57.6 ~ 67.2V
OVER TEMPERATURE
90 5 (70 5 5V only) (TSW1 : detect on heatsink of power transistor) ; 90 5 (TSW2 : detect on heatsink of power doide)
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
5V STANDBY
5VSB : 5V@0.3A ; tolerance 5%, ripple : 50mVp-p(max.)
DC OK SIGNAL
FUNCTION
REMOTE CONTROL
PSU turn on : 3.3 ~ 5.6V ; PSU turn off : 0 ~ 1V
RC+ / RC-: 4 ~ 10V or open = power on ; 0 ~ 0.8V or short = power off
FAN CONTROL (Typ.)
Load 20 10% or RTH2 50 Fan on
WORKING TEMP.
-30 ~ +70 (Refer to output load derating curve)
WORKING HUMIDITY
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03%/ (0 ~ 50 )
VIBRATION
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL60950-1, TUV EN60950-1 approved
SAFETY &
EMC
(Note 4)
WITHSTAND VOLTAGE
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, ENV50204, EN55024, EN61000-6-2, heavy industry level, criteria A
MTBF
130.5K hrs min. MIL-HDBK-217F (25 )
OTHERS DIMENSION
218*105*41mm (L*W*H)
PACKING
1.19Kg; 12pcs/15.3Kg/0.82CUFT
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. No load power consumption<0.5W when RC- & RC+ (CN100 pin1,2) 0 ~ 0.8V or short.
File Name:HRPG-450-SPEC 2010-07-19