English
Language : 

HRP-75_11 Datasheet, PDF (1/2 Pages) Mean Well Enterprises Co., Ltd. – 75W Single Output with PFC Function
75W Single Output with PFC Function
HRP-75 series
Features :
Universal AC input / Full range
Built-in active PFC function
Withstand 300VAC surge input for 5 seconds
Protections: Short circuit / Overload / Over voltage
Protections: Over temperature (optional)
Cooling by free air convection
1U low profile 38mm
Built-in remote ON-OFF control
No load power consumption<0.5W
All using 105 long life electrolytic capacitors
5 years warranty
SPECIFICATION
MODEL
HRP-75-3.3 HRP-75-5 HRP-75-7.5 HRP-75-12 HRP-75-15 HRP-75-24 HRP-75-36 HRP-75-48
OUTPUT
DC VOLTAGE
3.3V
5V
7.5V
12V
15V
RATED CURRENT
15A
15A
10A
6.3A
5A
CURRENT RANGE
0 ~ 15A
0 ~ 15A
0 ~ 10A
0 ~ 6.3A
0 ~ 5A
RATED POWER
49.5W
75W
75W
75.6W
75W
RIPPLE & NOISE (max.) Note.2 80mVp-p
80mVp-p
100mVp-p 120mVp-p 150mVp-p
VOLTAGE ADJ. RANGE
3.1 ~ 3.8V 4.7 ~ 5.8V 7.1 ~ 9V
11 ~ 13.8V 14.2 ~ 18V
VOLTAGE TOLERANCE Note.3 2.5%
2.5%
2.5%
1.5%
1.5%
LINE REGULATION
1.0%
1.0%
1.0%
0.3%
0.3%
LOAD REGULATION
2.0%
2.0%
1.5%
1.0%
0.5%
SETUP, RISE TIME
1800ms, 25ms/230VAC 1800ms, 25ms/115VAC at full load
HOLD UP TIME (Typ.)
50ms/230VAC 20ms/115VAC at full load
24V
3.2A
0 ~ 3.2A
76.8W
150mVp-p
21.6 ~ 28.8V
1.5%
0.2%
0.5%
36V
2.1A
0 ~ 2.1A
75.6W
200mVp-p
32 ~ 39.6V
1.5%
0.2%
0.5%
48V
1.6A
0 ~ 1.6A
76.8W
240mVp-p
45 ~ 55.2V
1.5%
0.2%
0.5%
VOLTAGE RANGE Note.5 85 ~ 264VAC 120 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.9/230VAC PF>0.95/115VAC at full load
INPUT EFFICIENCY (Typ.)
77%
82.5%
84%
87%
88%
88.5%
89%
89%
AC CURRENT (Typ.)
1.2A/115VAC 0.7A/230VAC
INRUSH CURRENT (Typ.) 35A/115VAC 65A/230VAC
LEAKAGE CURRENT
<1mA / 240VAC
OVERLOAD
105 ~ 135% rated output power
Protection type : Constant current limiting, switch to hiccup mode for Vo<50% of rated voltage, recovers automatically after fault condition is removed
PROTECTION OVER VOLTAGE
3.96 ~ 4.62V 6 ~ 7V
9.4 ~ 10.9V 14.4 ~ 16.8V 18.8 ~ 21.8V 30 ~ 34.8V
Protection type : Shut down o/p voltage, re-power on to recover
41.4 ~ 48.6V 57.6 ~ 67.2V
85 5 for 3.3V~15V; 80 5 for 24V~48V (TSW1 : detect on heatsink of power transistor) (optional)
OVER TEMPERATURE (OPTIONAL) Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
FUNCTION REMOTE CONTROL
RC+ / RC-: 0 ~ 0.8V = power on ; 4 ~ 10V = power off
WORKING TEMP.
-40 ~ +70 (Refer to "Derating Curve")
WORKING HUMIDITY
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03%/ (0 ~ 50
VIBRATION
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL60950-1, TUV EN60950-1 approved
SAFETY & WITHSTAND VOLTAGE
EMC
ISOLATION RESISTANCE
(Note 4) EMC EMISSION
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2, heavy industry level, criteria A
MTBF
394.8K hrs min. MIL-HDBK-217F (25 )
OTHERS DIMENSION
PACKING
129*98*38mm (L*W*H)
0.47Kg; 30pcs/ 15Kg/ 0.97CUFT
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
File Name:HRP-75-SPEC 2011-07-05