SPECIFICATION
MODEL
HRP-75-3.3 HRP-75-5 HRP-75-7.5 HRP-75-12 HRP-75-15 HRP-75-24 HRP-75-36 HRP-75-48
OUTPUT
DC VOLTAGE
3.3V
5V
7.5V
12V
15V
RATED CURRENT
15A
15A
10A
6.3A
5A
CURRENT RANGE
0 ~ 15A
0 ~ 15A
0 ~ 10A
0 ~ 6.3A
0 ~ 5A
RATED POWER
49.5W
75W
75W
75.6W
75W
RIPPLE & NOISE (max.) Note.2 80mVp-p
80mVp-p
100mVp-p 120mVp-p 150mVp-p
VOLTAGE ADJ. RANGE
3.1 ~ 3.8V 4.7 ~ 5.8V 7.1 ~ 9V
11 ~ 13.8V 14.2 ~ 18V
VOLTAGE TOLERANCE Note.3 2.5%
2.5%
2.5%
1.5%
1.5%
LINE REGULATION
1.0%
1.0%
1.0%
0.3%
0.3%
LOAD REGULATION
2.0%
2.0%
1.5%
1.0%
0.5%
SETUP, RISE TIME
1800ms, 25ms/230VAC 1800ms, 25ms/115VAC at full load
HOLD UP TIME (Typ.)
50ms/230VAC 20ms/115VAC at full load
24V
3.2A
0 ~ 3.2A
76.8W
150mVp-p
21.6 ~ 28.8V
1.5%
0.2%
0.5%
36V
2.1A
0 ~ 2.1A
75.6W
200mVp-p
32 ~ 39.6V
1.5%
0.2%
0.5%
48V
1.6A
0 ~ 1.6A
76.8W
240mVp-p
45 ~ 55.2V
1.5%
0.2%
0.5%
VOLTAGE RANGE Note.5 85 ~ 264VAC 120 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.9/230VAC PF>0.95/115VAC at full load
INPUT EFFICIENCY (Typ.)
77%
82.5%
84%
87%
88%
88.5%
89%
89%
AC CURRENT (Typ.)
1.2A/115VAC 0.7A/230VAC
INRUSH CURRENT (Typ.) 35A/115VAC 65A/230VAC
LEAKAGE CURRENT
<1mA / 240VAC
OVERLOAD
105 ~ 135% rated output power
Protection type : Constant current limiting, switch to hiccup mode for Vo<50% of rated voltage, recovers automatically after fault condition is removed
PROTECTION OVER VOLTAGE
3.96 ~ 4.62V 6 ~ 7V
9.4 ~ 10.9V 14.4 ~ 16.8V 18.8 ~ 21.8V 30 ~ 34.8V
Protection type : Shut down o/p voltage, re-power on to recover
41.4 ~ 48.6V 57.6 ~ 67.2V
85 5 for 3.3V~15V; 80 5 for 24V~48V (TSW1 : detect on heatsink of power transistor) (optional)
OVER TEMPERATURE (OPTIONAL) Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
FUNCTION REMOTE CONTROL
RC+ / RC-: 0 ~ 0.8V = power on ; 4 ~ 10V = power off
WORKING TEMP.
-20 ~ +70 (Refer to output load derating curve)
WORKING HUMIDITY
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03%/ (0 ~ 50
VIBRATION
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL60950-1, TUV EN60950-1 approved
SAFETY &
EMC
(Note 4)
WITHSTAND VOLTAGE
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN61000-6-2, heavy industry level, criteria A
MTBF
394.8K hrs min. MIL-HDBK-217F (25 )
OTHERS DIMENSION
PACKING
129*98*38mm (L*W*H)
0.47Kg; 30pcs/ 15Kg/ 0.97CUFT
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
File Name:HRP-75-SPEC 2009-10-09