English
Language : 

HRP-300_10 Datasheet, PDF (1/2 Pages) Mean Well Enterprises Co., Ltd. – 300W Single Output with PFC Function
300W Single Output with PFC Function
HRP-300 series
Features :
Universal AC input / Full range
Built-in active PFC function, PF>0.95
High efficiency up to 89%
Withstand 300VAC surge input for 5 seconds
Protections: Short circuit / Overload / Over voltage / Over temperature
Built-in constant current limiting circuit
1U low profile 41mm
Built-in cooling fan ON-OFF control
Built-in DC OK signal
Built-in remote sense function
5 years warranty
SPECIFICATION
MODEL
HRP-300-3.3 HRP-300-5 HRP-300-7.5 HRP-300-12 HRP-300-15 HRP-300-24 HRP-300-36 HRP-300-48
DC VOLTAGE
RATED CURRENT
3.3V
5V
7.5V
12V
15V
24V
36V
48V
60A
60A
40A
27A
22A
14A
9A
7A
CURRENT RANGE
0 ~ 60A
0 ~ 60A
0 ~ 40A
0 ~ 27A
0 ~ 22A
0 ~ 14A
0 ~ 9A
0 ~ 7A
RATED POWER
198W
300W
300W
324W
330W
336W
324W
336W
RIPPLE & NOISE (max.) Note.2 80mVp-p
90mVp-p
100mVp-p 120mVp-p 150mVp-p 150mVp-p 250mVp-p 250mVp-p
OUTPUT VOLTAGE ADJ. RANGE
2.8 ~ 3.8V
VOLTAGE TOLERANCE Note.3 2.5%
4.3 ~ 5.8V
2.0%
6.8 ~ 9V
2.0%
10.2 ~ 13.8V 13.5 ~ 18V
1.0%
1.0%
21.6 ~ 28.8V 28.8 ~ 39.6V 40.8 ~ 55.2V
1.0%
1.0%
1.0%
LINE REGULATION
0.5%
0.5%
0.5%
0.3%
0.3%
0.2%
0.2%
0.2%
LOAD REGULATION
1.0%
1.0%
1.0%
0.5%
0.5%
0.5%
0.5%
0.5%
SETUP, RISE TIME
1000ms, 50ms/230VAC 2500ms, 50ms/115VAC at full load
HOLD UP TIME (Typ.)
16ms/230VAC 16ms/115VAC at full load
VOLTAGE RANGE Note.5 85 ~ 264VAC
FREQUENCY RANGE
47 ~ 63Hz
120 ~ 370VDC
POWER FACTOR (Typ.)
PF>0.95/230VAC PF>0.99/115VAC at full load
INPUT EFFICIENCY (Typ.)
80%
82%
86%
88%
88%
87%
88%
89%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
5A/115VAC 2.5A/230VAC
35A/115VAC 70A/230VAC
LEAKAGE CURRENT
<1.2mA / 240VAC
OVERLOAD
OVER VOLTAGE
PROTECTION
105 ~ 135% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
3.96 ~ 4.62V 6 ~ 7V
9.4 ~ 10.9V 14.4 ~ 16.8V 18.8 ~ 21.8V 30 ~ 34.8V 41.4 ~ 48.6V
Protection type : Shut down o/p voltage, re-power on to recover
90 5 (TSW1: detect on heatsink of power transistor)
57.6 ~ 67.2V
OVER TEMPERATURE
100 5 for 3.3V,5V,7.5V ; 95 5 for others (TSW2: detect on heatsink of power diode)
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
DC OK SIGNAL
FUNCTION
FAN CONTROL (Typ.)
PSU turns on : 3.3 ~ 5.6V ; PSU turns off : 0 ~ 1V
Load 35 15% or RTH2 50 Fan on
WORKING TEMP.
-40 ~ +70 (Refer to output load derating curve)
WORKING HUMIDITY
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03%/ (0 ~ 50 )
VIBRATION
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY &
EMC
(Note 4)
SAFETY STANDARDS
UL60950-1, TUV EN60950-1 approved
WITHSTAND VOLTAGE
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, ENV50204, EN55024, EN61000-6-2, heavy industry level, criteria A
MTBF
176K hrs min. MIL-HDBK-217F (25 )
OTHERS DIMENSION
199*105*41mm (L*W*H)
PACKING
0.95Kg;15pcs/15.3Kg/0.69CUFT
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
File Name:HRP-300-SPEC 2010-11-29