English
Language : 

HLP-80H Datasheet, PDF (1/4 Pages) Mean Well Enterprises Co., Ltd. – 80W Single Output Switching Power Supply
80W Single Output Switching Power Supply
HLP-80H series
Features :
Universal AC input / Full range (up to 305VAC)
Built-in active PFC function, PF>0.96
Protections: Short circuit / Over current / Over voltage / Over temperature
Cooling by free air convection
Output constant current level adjustable
100% full load burn-in test
Three in one dimming function (1~10Vdc or PWM signal or resistance)
Suitable for built in LED lighting system
Suitable for dry / damp location
3 years warranty
SPECIFICATION
M M SELV
MODEL
HLP-80H-12 HLP-80H-15 HLP-80H-20 HLP-80H-24 HLP-80H-30 HLP-80H-36 HLP-80H-42 HLP-80H-48 HLP-80H-54
OUTPUT
DC VOLTAGE
12V
15V
20V
CONSTANT CURRENT REGION Note.4 7.2 ~12V 9 ~ 15V
12 ~ 20V
RATED CURRENT
5A
5A
4A
RATED POWER
60W
75W
80W
RIPPLE & NOISE (max.) Note.2 150mVp-p 150mVp-p 150mVp-p
VOLTAGE TOLERANCE Note.3 2.5%
2.0%
1.0%
LINE REGULATION
0.5%
0.5%
0.5%
LOAD REGULATION
2.0%
1.5%
1.0%
SETUP, RISE TIME Note.6 2000ms, 200ms / 115VAC at full load
HOLD UP TIME (Typ.)
16ms at full load 230VAC /115VAC
24V
30V
36V
14.4 ~ 24V 18 ~ 30V 21.6 ~ 36V
3.4A
2.7A
2.3A
81.6W
81W
82.8W
150mVp-p 200mVp-p 200mVp-p
1.0%
1.0%
1.0%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
1000ms, 200ms / 230VAC at full load
42V
25.2 ~ 42V
1.95A
81.9W
200mVp-p
1.0%
0.5%
0.5%
48V
28.8 ~ 48V
1.7A
81.6W
200mVp-p
1.0%
0.5%
0.5%
54V
32.4 ~ 54V
1.5A
81W
200mVp-p
1.0%
0.5%
0.5%
VOLTAGE RANGE Note.5 90 ~ 305VAC 127 ~ 431VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.96/115VAC, PF>0.96/230VAC, PF>0.94/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
INPUT EFFICIENCY (Typ.)
87.5%
88.5%
89.5%
90%
90%
90%
90%
90%
90%
AC CURRENT (Typ.)
0.85A / 115VAC 0.425A / 230VAC 0.4A / 277VAC
INRUSH CURRENT(Typ.)
COLD START 70A/230VAC
LEAKAGE CURRENT
<0.75mA / 277VAC
OVER CURRENT
PROTECTION OVER VOLTAGE
95 ~ 108%
Note.4
Protection type : Constant current limiting, recovers automatically after fault condition is removed
14 ~ 17V 18 ~ 21V 23 ~ 27V 28 ~ 34V 34 ~ 38V 41 ~ 46V 47 ~ 53V
Protection type : Shut down o/p voltage, re-power on to recover
54 ~ 60V
59 ~ 65V
OVER TEMPERATURE
95 10 (RTH2)
Protection type : Shut down o/p voltage, re-power on to recover
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
-40 ~ +70 (Refer to "Derating Curve")
20 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH
0.03%/ (0 ~ 50 )
VIBRATION
10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY STANDARDS
UL8750, EN61347-1, EN61347-2-13 approved ; Design refer to UL60950-1, TUV EN60950-1
WITHSTAND VOLTAGE
I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC
SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
EMC
EMC EMISSION
Compliance to EN55015, EN61000-3-2 Class C ( 60% load, 12V model 65% load) ; EN61000-3-3
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge 4KV), criteria A
MTBF
316.2Khrs min. MIL-HDBK-217F (25 )
OTHERS DIMENSION
167*53*29.5mm (L*W*H)
PACKING
0.27Kg; 36pcs/11.2Kg/0.67CUFT
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Constant current operation region is within 60% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
5. Derating may be needed under low input voltages. Please check the static characteristics for more details.
6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
8. Heat Sink HS1,HS2 can not be shorted.
File Name:HLP-80H-SPEC 2011-07-28