HLP-60H Datasheet, PDF (1/4 Pages) Mean Well Enterprises Co., Ltd. – 60W Single Output Switching Power Supply
60W Single Output Switching Power Supply
HLP-60H series
Features :
Universal AC input / Full range (up to 305VAC)
Built-in active PFC function, PF>0.95
Protections: Short circuit / Overload / Over voltage / Over temperature
Cooling by free air convection
Output constant current level adjustable
100% full load burn-in test
Three in one dimming function (1~10Vdc or PWM signal or resistance)
Suitable for built in LED lighting system
Suitable for dry / damp location
3 years warranty
SPECIFICATION
M M SELV
MODEL
HLP-60H-15 HLP-60H-20 HLP-60H-24 HLP-60H-30 HLP-60H-36 HLP-60H-42 HLP-60H-48 HLP-60H-54
OUTPUT
DC VOLTAGE
15V
20V
24V
30V
36V
CONSTANT CURRENT REGION Note.4 9 ~ 15V
12 ~ 20V
14.4 ~ 24V 18 ~ 30V
21.6 ~ 36V
RATED CURRENT
4A
3A
2.5A
2A
1.7A
RATED POWER
60W
60W
60W
60W
61.2W
RIPPLE & NOISE (max.) Note.2 150mVp-p 150mVp-p 150mVp-p 200mVp-p 200mVp-p
VOLTAGE ADJ. RANGE
13.5 ~ 17V 17 ~ 22V
22 ~ 27V
27 ~ 33V
33 ~ 40V
CURRENT ADJ. RANGE
Can be adjusted by internal potential meter or through output cable
2.4 ~ 4A
1.8 ~ 3A
1.5 ~ 2.5A 1.2 ~ 2A
1 ~ 1.7A
VOLTAGE TOLERANCE Note.3 2.0%
1.0%
1.0%
1.0%
1.0%
LINE REGULATION
0.5%
0.5%
0.5%
0.5%
0.5%
LOAD REGULATION
1.5%
1.0%
0.5%
0.5%
0.5%
SETUP, RISE TIME Note.6 1500ms, 80ms / 115VAC at full load 1000ms, 80ms / 230VAC at full load
HOLD UP TIME (Typ.)
16ms/230VAC 16ms/115VAC at full load
42V
25.2 ~ 42V
1.45A
60.9W
300mVp-p
40 ~ 46V
48V
28.8 ~ 48V
1.3A
62.4W
300mVp-p
44 ~ 53V
54V
32.4 ~ 54V
1.15A
62.1W
300mVp-p
49 ~ 58V
0.87 ~ 1.45A
1.0%
0.5%
0.5%
0.78 ~ 1.3A
1.0%
0.5%
0.5%
0.69 ~ 1.15A
1.0%
0.5%
0.5%
INPUT
VOLTAGE RANGE Note.5 90 ~ 305VAC 127 ~ 431VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.97/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
EFFICIENCY (Typ.)
88%
89%
89.5%
90%
90%
90%
90%
91%
AC CURRENT (Typ.)
0.64A / 115VAC 0.32A / 230VAC 0.3A / 277VAC
INRUSH CURRENT (Typ.) COLD START 70A/230VAC
LEAKAGE CURRENT
<0.75mA / 277VAC
OVER CURRENT
PROTECTION OVER VOLTAGE
95 ~ 108%
Note.4
Protection type : Constant current limiting, recovers automatically after fault condition is removed
18 ~ 24V
23 ~ 30V
28 ~ 35V
35 ~ 43V
41 ~ 49V
48 ~ 58V
Protection type : Shut down o/p voltage, re-power on to recover
54 ~ 63V
59 ~ 66V
OVER TEMPERATURE
85 10 (RTH2)
Protection type : Shut down o/p voltage, re-power on to recover
WORKING TEMP.
-40 ~ +70 (Refer to "Derating Curve")
WORKING HUMIDITY
20 ~ 95% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +80 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03%/ (0 ~ 50 )
VIBRATION
10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY STANDARDS
UL8750, EN61347-1, EN61347-2-13 approved ; Design refer to UL60950-1, TUV EN60950-1, EN60335-1
SAFETY & WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC
EMC EMISSION
I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55015, EN61000-3-2 Class C ( 60% load) ; EN61000-3-3
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, EN55024, light industry level (surge 4KV), criteria A
MTBF
288.5Khrs min. MIL-HDBK-217F (25 )
OTHERS DIMENSION
147*53*27mm (L*W*H)
PACKING
0.2Kg;72pcs/15.4Kg/1.09CUFT
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Constant current operation region is within 60% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
5. Derating may be needed under low input voltages. Please check the static characteristics for more details.
6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
File Name:HLP-60H-SPEC 2011-06-03