English
Language : 

HLN-40H Datasheet, PDF (1/5 Pages) Mean Well Enterprises Co., Ltd. – 40W Single Output Switching Power Supply
40W Single Output Switching Power Supply
HLN-40H series
Features :
Universal AC input / Full range (up to 305VAC)
Built-in active PFC function
Protections: Short circuit / Overload / Over voltage / Over temperature
Cooling by free air convection
OCP point adjustable through output cable or internal potential meter
IP64 design for indoor or outdoor installations
Three in one dimming function (1~10Vdc or PWM signal or resistance)
Suitable for LED lighting and moving sign applications
Compliance to worldwide safety regulations for lighting
Suitable for dry / damp location or outdoor application
3 years warranty
F 110 M M SELV IP64
HLN-40H-12 A A : IP64 rated. Output voltage and constant current level can be adjusted through internal potential meter.
B : IP64 rated. Constant current level adjustable through output cable with 1~10Vdc or 10V PWM signal or resistance.
SPECIFICATION
MODEL
HLN-40H-12 HLN-40H-15 HLN-40H-20 HLN-40H-24 HLN-40H-30 HLN-40H-36 HLN-40H-42 HLN-40H-48 HLN-40H-54
OUTPUT
DC VOLTAGE
12V
15V
20V
24V
30V
CONSTANT CURRENT REGION Note.4 7.2 ~12V 9 ~ 15V
12 ~ 20V 14.4 ~ 24V 18 ~ 30V
RATED CURRENT
3.33A
2.67A
2A
1.67A
1.34A
RATED POWER
40W
40W
40W
40.1W
40.2W
RIPPLE & NOISE (max.) Note.2 150mVp-p 150mVp-p 150mVp-p 150mVp-p 200mVp-p
VOLTAGE ADJ. RANGE Note.6 10.8 ~ 13.5V 13.5 ~ 17V 17 ~ 22V 22 ~ 27V 27 ~ 33V
CURRENT ADJ. RANGE
Can be adjusted by internal potential meter or through output cable
2 ~ 3.33A 1.6 ~ 2.67A 1.2 ~ 2A 1 ~ 1.67A 0.8 ~ 1.34A
VOLTAGE TOLERANCE Note.3 2.5%
2.0%
1.0%
1.0%
1.0%
LINE REGULATION
0.5%
0.5%
0.5%
0.5%
0.5%
LOAD REGULATION
2.0%
1.5%
1.0%
0.5%
0.5%
36V
21.6 ~ 36V
1.12A
40.3W
200mVp-p
33 ~ 40V
42V
25.2 ~ 42V
0.96A
40.3W
300mVp-p
40 ~ 46V
48V
28.8 ~ 48V
0.84A
40.3W
300mVp-p
44 ~ 53V
0.67 ~ 1.12A 0.58 ~ 0.96A 0.5 ~ 0.84A
1.0%
1.0%
1.0%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
54V
32.4 ~ 54V
0.75A
40.5W
300mVp-p
49 ~ 58V
0.45 ~ 0.75A
1.0%
0.5%
0.5%
SETUP, RISE TIME Note.7 1500ms, 80ms / 115VAC at full load 1000ms, 80ms / 230VAC at full load
HOLD UP TIME (Typ.)
16ms/230VAC 16ms/115VAC at full load
VOLTAGE RANGE Note.5 90 ~ 305VAC
FREQUENCY RANGE
47 ~ 63Hz
127 ~ 431VDC
POWER FACTOR (Typ.)
PF>0.97/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
INPUT EFFICIENCY (Typ.)
87%
87%
88%
88.5%
89%
89%
90%
90%
90%
AC CURRENT (Typ.)
0.43A / 115VAC 0.24A / 230VAC 0.23A / 277VAC
INRUSH CURRENT(Typ.)
COLD START 70A/230VAC
LEAKAGE CURRENT
<0.75mA / 277VAC
OVER CURRENT
PROTECTION OVER VOLTAGE
95 ~ 108%
Note.4
Protection type : Constant current limiting, recovers automatically after fault condition is removed
12 ~ 21V 18 ~ 24V 23 ~ 30V 28 ~ 35V 35 ~ 43V 41 ~ 49V 48 ~ 58V
Protection type : Shut down o/p voltage, re-power on to recover
54 ~ 63V
59 ~ 66V
OVER TEMPERATURE
70 10 (RTH2)
Protection type : Shut down o/p voltage, re-power on to recover
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
-40 ~ +50 (Refer to "Derating Curve")
20 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH
0.03%/ (0 ~ 40 )
VIBRATION
SAFETY STANDARDS
10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes
UL8750, EN61347-1, EN61347-2-13 independent, IP64 approved ; Design refer to UL60950-1, TUV EN60950-1, EN60335-1
WITHSTAND VOLTAGE
SAFETY &
EMC
ISOLATION RESISTANCE
EMC EMISSION
I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55015, EN61000-3-2 Class C ( 60% load) ; EN61000-3-3
OTHERS
NOTE
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, EN55024, light industry level (surge 4KV), criteria A
MTBF
336.5Khrs min. MIL-HDBK-217F (25 )
DIMENSION
161*61.5*35mm (L*W*H)
PACKING
0.35Kg;40pcs/15Kg/1.36CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Constant current operation region is within 60% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
5. Derating may be needed under low input voltages. Please check the static characteristics for more details.
6. Type A only.
7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
File Name:HLN-40H-SPEC 2011-06-03