English
Language : 

HLG-80H_12 Datasheet, PDF (1/6 Pages) Mean Well Enterprises Co., Ltd. – 80W Single Output Switching Power Supply
80W Single Output Switching Power Supply
HLG-80H series
Features :
Universal AC input / Full range (up to 305VAC)
Built-in active PFC function
Protections: Short circuit / Over current / Over voltage / Over temperature
Cooling by free air convection
OCP point adjustable through output cable or internal potentiometer
IP67 / IP65 design for indoor or outdoor installations
"UL8750 listed" safety approved for HLG-80H- BL
Class 2 power unit
Three in one dimming function (1~10Vdc or PWM signal or resistance)
Suitable for LED lighting and moving sign applications
Compliance to worldwide safety regulations for lighting
Suitable for dry / damp / wet locations
5 years warranty (Note.10)
F 110
HLG-80H-12 A
M M SELV IP65 IP67
(for HLG-80H-48/54 only) (except for HLG-80H-48/54)
(except for BL type) (except for HLG-80H-48/54BL)
(for HLG-80H-48/54BL only)
(for HLG-80H-12~42BL only)
Blank : IP67 rated. Cable for I/O connection.
A : IP65 rated. Output voltage and constant current level can be adjusted through internal potentiometer.
B : IP67 rated. Constant current level adjustable through output cable with 1~10Vdc or 10V PWM signal or resistance.
BL (option) : Contact MEAN WELL for details.
D (option) : IP67 rated. Timer dimming function, contact MEAN WELL for details.
SPECIFICATION
MODEL
HLG-80H-12 HLG-80H-15 HLG-80H-20 HLG-80H-24 HLG-80H-30 HLG-80H-36 HLG-80H-42 HLG-80H-48 HLG-80H-54
DC VOLTAGE
12V
15V
CONSTANT CURRENT REGION Note.4 7.2 ~12V 9 ~ 15V
RATED CURRENT
5A
5A
RATED POWER
60W
75W
RIPPLE & NOISE (max.) Note.2 150mVp-p 150mVp-p
VOLTAGE ADJ. RANGE Note.6 10.8 ~ 13.5V 13.5 ~ 17V
20V
12 ~ 20V
4A
80W
150mVp-p
17 ~ 22V
24V
14.4 ~ 24V
3.4A
81.6W
150mVp-p
22 ~ 27V
30V
18 ~ 30V
2.7A
81W
200mVp-p
27 ~ 33V
36V
21.6 ~ 36V
2.3A
82.8W
200mVp-p
33 ~ 40V
42V
25.2 ~ 42V
1.95A
81.9W
200mVp-p
38 ~ 46V
48V
28.8 ~ 48V
1.7A
81.6W
200mVp-p
43 ~ 53V
54V
32.4 ~ 54V
1.5A
81W
200mVp-p
49 ~ 58V
OUTPUT
CURRENT ADJ. RANGE
Can be adjusted by internal potentiometer or through output cable
3 ~ 5A
3 ~ 5A
2.4 ~ 4A 2.04 ~ 3.4A 1.62 ~ 2.7A 1.38 ~ 2.3A 1.17 ~ 1.95A 1.02 ~ 1.7A 0.9 ~ 1.5A
VOLTAGE TOLERANCE Note.3 2.5%
2.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
LINE REGULATION
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
LOAD REGULATION
2.0%
1.5%
1.0%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
SETUP, RISE TIME Note.8 2000ms, 80ms / 115VAC at full load 1000ms, 80ms / 230VAC at full load ; B type 2000ms, 200ms at 95% load 230VAC / 115VAC
HOLD UP TIME (Typ.)
16ms at full load 230VAC /115VAC
VOLTAGE RANGE Note.5 90 ~ 305VAC 127 ~ 431VDC
INPUT
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
47 ~ 63Hz
PF>0.96/115VAC, PF>0.96/230VAC, PF>0.94/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
88%
89%
90%
90.5%
91%
91%
91%
91%
91%
0.85A / 115VAC 0.425A / 230VAC 0.4A / 277VAC
COLD START 70A/230VAC
LEAKAGE CURRENT
<0.75mA / 277VAC
OVER CURRENT
SHORT CIRCUIT
PROTECTION
OVER VOLTAGE
95 ~ 108%
Note.4
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Hiccup mode, recovers automatically after fault condition is removed
14 ~ 17V 18 ~ 24V 23 ~ 30V 28 ~ 35V 35 ~ 43V 41 ~ 49V 48 ~ 58V
Protection type : Shut down o/p voltage, re-power on to recover
54 ~ 63V
59 ~ 68V
OVER TEMPERATURE
85 10 (RTH2)
Protection type : Shut down o/p voltage, re-power on to recover
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
-40 ~ +70 (Refer to "Derating Curve")
20 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH
0.03%/ (0 ~ 60 )
VIBRATION
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY &
EMC
UL8750, CSA C22.2 No. 250.0-08(except for HLG-80H-48/54V & HLG-80H-48/54BL), UL8750 listed for HLG-80H- BL
SAFETY STANDARDS Note.7
EN61347-1, EN61347-2-13 independent, J61347-1, J61347-2-13, IP65 or IP67 approved ; Design refer to UL60950-1, TUV EN60950-1
WITHSTAND VOLTAGE
I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
EMC EMISSION
Compliance to EN55015, EN61000-3-2 Class C ( 60% load) ; EN61000-3-3
EMC IMMUNITY
MTBF
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge 4KV), criteria A
357.8Khrs min. MIL-HDBK-217F (25 )
OTHERS
NOTE
DIMENSION
195.6*61.5*38.8mm (L*W*H)
PACKING
0.84Kg; 16pcs/14.4Kg/0.54CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Constant current operation region is within 60% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
5. Derating may be needed under low input voltages. Please check the static characteristics for more details.
6. Type A only.
7. Safety and EMC design refer to EN60598-1, CNS15233, GB7000.1, FCC part18.
8. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
9. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
10. Refer to warranty statement.