English
Language : 

HLG-60H_1108 Datasheet, PDF (1/6 Pages) Mean Well Enterprises Co., Ltd. – 60W Single Output Switching Power Supply
60W Single Output Switching Power Supply
HLG-60H series
F 110 M M SELV IP65 IP67
Features :
Universal AC input / Full range (up to 305VAC)
Built-in active PFC function
Protections: Short circuit / Over current / Over voltage / Over temperature
Cooling by free air convection
OCP point adjustable through output cable or internal potentiometer
IP67 / IP65 design for indoor or outdoor installations
Three in one dimming function (1~10Vdc or PWM signal or resistance)
Suitable for LED lighting and moving sign applications
Compliance to worldwide safety regulations for lighting
Suitable for dry / damp / wet location
5 years warranty (Note.10)
( for 48V,54V only)
( except for 48V,54V )
HLG-60H-12 A
Blank : IP67 rated. Cable for I/O connection.
A : IP65 rated. Output voltage and constant current level can be adjusted through internal potentiometer.
B : IP67 rated. Constant current level adjustable through output cable with 1~10Vdc or 10V PWM signal or resistance.
D (option) : IP67 rated. Timer dimming function, contact MEAN WELL for details.
SPECIFICATION
MODEL
HLG-60H-15 HLG-60H-20 HLG-60H-24 HLG-60H-30 HLG-60H-36 HLG-60H-42 HLG-60H-48 HLG-60H-54
DC VOLTAGE
15V
CONSTANT CURRENT REGION Note.4 9 ~ 15V
RATED CURRENT
4A
RATED POWER
60W
RIPPLE & NOISE (max.) Note.2 150mVp-p
VOLTAGE ADJ. RANGE Note.6 13.5 ~ 17V
20V
12 ~ 20V
3A
60W
150mVp-p
17 ~ 22V
24V
14.4 ~ 24V
2.5A
60W
150mVp-p
22 ~ 27V
30V
18 ~ 30V
2A
60W
200mVp-p
27 ~ 33V
36V
21.6 ~ 36V
1.7A
61.2W
200mVp-p
33 ~ 40V
42V
25.2 ~ 42V
1.45A
60.9W
300mVp-p
40 ~ 46V
48V
28.8 ~ 48V
1.3A
62.4W
300mVp-p
44 ~ 53V
54V
32.4 ~ 54V
1.15A
62.1W
300mVp-p
49 ~ 58V
OUTPUT
CURRENT ADJ. RANGE
Can be adjusted by internal potentiometer or through output cable
2.4 ~ 4A
1.8 ~ 3A
1.5 ~ 2.5A 1.2 ~ 2A
1 ~ 1.7A
VOLTAGE TOLERANCE Note.3 2.0%
1.0%
1.0%
1.0%
1.0%
LINE REGULATION
0.5%
0.5%
0.5%
0.5%
0.5%
LOAD REGULATION
1.5%
1.0%
0.5%
0.5%
0.5%
0.87 ~ 1.45A
1.0%
0.5%
0.5%
0.78 ~ 1.3A
1.0%
0.5%
0.5%
0.69 ~ 1.15A
1.0%
0.5%
0.5%
SETUP, RISE TIME Note.8 1500ms, 80ms / 115VAC at full load 1000ms, 80ms / 230VAC at full load
HOLD UP TIME (Typ.)
16ms/230VAC 16ms/115VAC at full load
VOLTAGE RANGE Note.5 90 ~ 305VAC
FREQUENCY RANGE
47 ~ 63Hz
127 ~ 431VDC
POWER FACTOR (Typ.)
PF>0.98/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
INPUT EFFICIENCY (Typ.)
87.5%
89%
89.5%
90%
90%
90%
90.5%
90.5%
AC CURRENT (Typ.)
0.64A / 115VAC 0.32A / 230VAC 0.3A / 277VAC
INRUSH CURRENT(Typ.)
COLD START 70A/230VAC
LEAKAGE CURRENT
<0.75mA / 277VAC
OVER CURRENT
SHORT CIRCUIT
PROTECTION
OVER VOLTAGE
Note.4 95 ~ 108%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Hiccup mode, recovers automatically after fault condition is removed
18 ~ 24V
23 ~ 30V
28 ~ 35V
35 ~ 43V
41 ~ 49V
48 ~ 58V
Protection type : Shut down o/p voltage, re-power on to recover
54 ~ 63V
59 ~ 68V
OVER TEMPERATURE
95 10 (RTH2)
Protection type : Shut down o/p voltage, re-power on to recover
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
-40 ~ +70 (Refer to "Derating Curve")
20 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH
0.03%/ (0 ~ 60 )
VIBRATION
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
UL8750, CSA C22.2 No. 250.0-08 (except for 48V, 54V), EN61347-1, EN61347-2-13 independent ; IP65 or IP67 approved ;
SAFETY STANDARDS Note.7
Design refer to UL60950-1, TUV EN60950-1, EN60335-1
SAFETY & WITHSTAND VOLTAGE
EMC
ISOLATION RESISTANCE
EMC EMISSION
I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55015, EN61000-3-2 Class C ( 60% load) ; EN61000-3-3
OTHERS
NOTE
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, EN55024, light industry level (surge 4KV), criteria A
MTBF
338Khrs min. MIL-HDBK-217F (25 )
DIMENSION
171*61.5*36.8mm (L*W*H)
PACKING
0.73Kg; 20pcs/15.6Kg/0.8CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Constant current operation region is within 60% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
5. Derating may be needed under low input voltages. Please check the static characteristics for more details.
6. Type A only.
7. Safety and EMC design refer to EN60598-1, CNS15233, GB7000.1, FCC part18.
8. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
9. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
10. Refer to warranty statement.