English
Language : 

HLG-40H_1209 Datasheet, PDF (1/6 Pages) Mean Well Enterprises Co., Ltd. – 40W Single Output Switching Power Supply
40W Single Output Switching Power Supply
HLG-40H series
¡½ Features :
¡EUniversal AC input / Full range (up to 305VAC)
¡EBuilt-in active PFC function
¡EProtections: Short circuit / Over current / Over voltage / Over temperature
¡ECooling by free air convection
¡EOCP point adjustable through output cable or internal potentiometer
¡EIP67 / IP65 design for indoor or outdoor installations
¡EClass 2 power unit
¡EThree in one dimming function (1~10Vdc or PWM signal or resistance)
¡ESuitable for LED lighting and moving sign applications
¡ECompliance to worldwide safety regulations for lighting
¡ESuitable for dry / damp / wet locations
¡E5 years warranty (Note.10)
F 110 M M SELV IP65 IP67
( for 48V,54V only)
( except for 48V,54V )
HLG-40H-12 A
Blank : IP67 rated. Cable for I/O connection.
A : IP65 rated. Output voltage and constant current level can be adjusted through internal potentiometer.
B : IP67 rated. Constant current level adjustable through output cable with 1~10Vdc or 10V PWM signal or resistance
D (option) : IP67 rated. Timer dimming function, contact MEAN WELL for details.
SPECIFICATION
MODEL
HLG-40H-12 HLG-40H-15 HLG-40H-20 HLG-40H-24 HLG-40H-30 HLG-40H-36 HLG-40H-42 HLG-40H-48 HLG-40H-54
DC VOLTAGE
12V
15V
CONSTANT CURRENT REGION Note.4 7.2 ~12V 9 ~ 15V
RATED CURRENT
3.33A
2.67A
RATED POWER
39.96W
40.05W
RIPPLE & NOISE (max.) Note.2 150mVp-p 150mVp-p
VOLTAGE ADJ. RANGE Note.6 10.8 ~ 13.5V 13.5 ~ 17V
20V
12 ~ 20V
2A
40W
150mVp-p
17 ~ 22V
24V
14.4 ~ 24V
1.67A
40.08W
200mVp-p
22 ~ 27V
30V
18 ~ 30V
1.34A
40.2W
200mVp-p
27 ~ 33V
36V
21.6 ~ 36V
1.12A
40.32W
200mVp-p
33 ~ 40V
42V
25.2 ~ 42V
0.96A
40.32W
200mVp-p
40 ~ 46V
48V
28.8 ~ 48V
0.84A
40.32W
300mVp-p
44 ~ 53V
54V
32.4 ~ 54V
0.75A
40.5W
300mVp-p
49 ~ 58V
OUTPUT
Can be adjusted by internal potentiometer A type only
CURRENT ADJ. RANGE
2 ~ 3.33A 1.6 ~ 2.67A 1.2 ~ 2A 1 ~ 1.67A
¡Ó VOLTAGE TOLERANCE Note.3 2.5%
¡Ó2.0%
¡Ó1.0%
¡Ó1.0%
LINE REGULATION
¡Ó0.5%
¡Ó0.5%
¡Ó0.5%
¡Ó0.5%
LOAD REGULATION
¡Ó2.0%
¡Ó1.5%
¡Ó1.0%
¡Ó0.5%
0.8 ~ 1.34A
¡Ó1.0%
¡Ó0.5%
¡Ó0.5%
0.67 ~ 1.12A 0.58 ~ 0.96A 0.5 ~ 0.84A
¡Ó1.0%
¡Ó1.0%
¡Ó1.0%
¡Ó0.5%
¡Ó0.5%
¡Ó0.5%
¡Ó0.5%
¡Ó0.5%
¡Ó0.5%
SETUP, RISE TIME Note.8 1500ms, 80ms / 115VAC at full load 1000ms, 80ms / 230VAC at full load
0.45 ~ 0.75A
¡Ó1.0%
¡Ó0.5%
¡Ó0.5%
HOLD UP TIME (Typ.)
16ms/230VAC 16ms/115VAC at full load
VOLTAGE RANGE Note.5 90 ~ 305VAC 127 ~ 431VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.98/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
INPUT
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT(Typ.)
86.5%
86.5%
88%
0.43A / 115VAC 0.24A / 230VAC
COLD START 70A/230VAC
88%
88.5%
0.23A / 277VAC
88.5%
88.5%
89.5%
89.5%
LEAKAGE CURRENT
<0.75mA / 277VAC
OVER CURRENT
95 ~ 108%
Note.4
Protection type : Constant current limiting, recovers automatically after fault condition is removed
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
PROTECTION
OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
15 ~ 21V 18 ~ 24V 23 ~ 30V 28 ~ 35V 35 ~ 43V
Protection type : Shut down o/p voltage, re-power on to recover
85¢J¡Ó10¢J (RTH2)
Protection type : Shut down o/p voltage, re-power on to recover
¢J -40 ~ +70 (Refer to "Derating Curve")
41 ~ 49V
48 ~ 58V
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
20 ~ 95% RH non-condensing
¢J -40 ~ +80 , 10 ~ 95% RH
¡Ó ¢J ¢J 0.03%/ (0 ~ 60 )
54 ~ 63V
59 ~ 68V
VIBRATION
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
UL8750, CSA C22.2 No. 250.0-08 (except for 48V, 54V), EN61347-1, EN61347-2-13 independent, IP65 or IP67, J61347-1,
SAFETY STANDARDS Note.7
J61347-2-13 approved ; design refer to UL60950-1, TUV EN60950-1, EN60335-1
SAFETY & WITHSTAND VOLTAGE
EMC
ISOLATION RESISTANCE
EMC EMISSION
I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC
¢J I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
¡Ù Compliance to EN55015, EN61000-3-2 Class C ( 60% load) ; EN61000-3-3
OTHERS
NOTE
EMC IMMUNITY
MTBF
Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, EN55024, light industry level (surge 4KV), criteria A
¢J 336.5K hrs min. MIL-HDBK-217F (25 )
DIMENSION
171*61.5*36.8mm (L*W*H)
¢J PACKING
0.73Kg; 20pcs/15.6Kg/0.8CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Constant current operation region is within 60% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
5. Derating may be needed under low input voltages. Please check the static characteristics for more details.
6. Type A only.
7. Safety and EMC design refer to EN60598-1, CNS15233, GB7000.1, FCC part18.
8. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
9. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
10. Refer to warranty statement.