English
Language : 

HLG-40H Datasheet, PDF (1/7 Pages) Mean Well Enterprises Co., Ltd. – 40W Single Output Switching Power Supply
40W Single Output Switching Power Supply
HLG-40H series
Features :
Universal AC input / Full range (up to 305VAC)
Built-in active PFC function
Protections: Short circuit / Overload / Over voltage / Over temperature
Cooling by free air convection
OCP point adjustable through output cable or internal potential meter
IP67 / IP65 design for indoor or outdoor installations
Three in one dimming function (1~10Vdc or PWM signal or resistance)
Suitable for LED lighting and moving sign applications
Compliance to worldwide safety regulations for lighting
Suitable for dry / damp / wet location or outdoor application
5 years warranty
F 110 M M SELV IP65 IP67
HLG-40H-12 A
Blank : IP67 rated. Cable for I/O connection.
A : IP65 rated. Output voltage and constant current level can be adjusted through internal potential meter.
B : IP67 rated. Constant current level adjustable through output cable with 1~10Vdc or 10V PWM signal or resistance
D : (option) : IP67 rated. Timer dimming function, contact MEAN WELL for details.
SPECIFICATION
MODEL
HLG-40H-12 HLG-40H-15 HLG-40H-20 HLG-40H-24 HLG-40H-30 HLG-40H-36 HLG-40H-42 HLG-40H-48 HLG-40H-54
OUTPUT
DC VOLTAGE
12V
15V
20V
24V
30V
36V
42V
48V
CONSTANT CURRENT REGION Note.4 7.2 ~12V 9 ~ 15V
12 ~ 20V 14.4 ~ 24V 18 ~ 30V 21.6 ~ 36V 25.2 ~ 42V 28.8 ~ 48V
RATED CURRENT
3.33A
2.67A
2A
1.67A
1.34A
1.12A
0.96A
0.84A
RATED POWER
39.96W
40.05W
40W
40.08W
40.2W
40.32W
40.32W
40.32W
RIPPLE & NOISE (max.) Note.2 150mVp-p 150mVp-p 150mVp-p 200mVp-p 200mVp-p 200mVp-p 200mVp-p 300mVp-p
VOLTAGE ADJ. RANGE Note.6 10.8 ~ 13.5V 13.5 ~ 17V 17 ~ 22V 22 ~ 27V 27 ~ 33V 33 ~ 40V 40 ~ 46V 44 ~ 53V
CURRENT ADJ. RANGE
Can be adjusted by internal potential meter or through output cable
2 ~ 3.33A 1.6 ~ 2.67A 1.2 ~ 2A 1 ~ 1.67A 0.8 ~ 1.34A 0.67 ~ 1.12A 0.58 ~ 0.96A 0.5 ~ 0.84A
VOLTAGE TOLERANCE Note.3 2.5%
2.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
LINE REGULATION
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
LOAD REGULATION
2.0%
1.5%
1.0%
0.5%
0.5%
0.5%
0.5%
0.5%
SETUP, RISE TIME Note.8 1500ms, 80ms / 115VAC at full load 1000ms, 80ms / 230VAC at full load
HOLD UP TIME (Typ.)
16ms/230VAC 16ms/115VAC at full load
54V
32.4 ~ 54V
0.75A
40.5W
300mVp-p
49 ~ 58V
0.45 ~ 0.75A
1.0%
0.5%
0.5%
INPUT
VOLTAGE RANGE Note.5 90 ~ 305VAC 127 ~ 431VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.98/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
EFFICIENCY (Typ.)
87%
87%
88.5%
88.5%
89%
89%
90%
90%
90%
AC CURRENT (Typ.)
0.43A / 115VAC 0.24A / 230VAC 0.23A / 277VAC
INRUSH CURRENT(Typ.)
COLD START 70A/230VAC
LEAKAGE CURRENT
<0.75mA / 277VAC
OVER CURRENT
PROTECTION OVER VOLTAGE
95 ~ 108%
Note.4
Protection type : Constant current limiting, recovers automatically after fault condition is removed
15 ~ 21V 18 ~ 24V 23 ~ 30V 28 ~ 35V 35 ~ 43V 41 ~ 49V 48 ~ 58V
Protection type : Shut down o/p voltage, re-power on to recover
54 ~ 63V
59 ~ 66V
OVER TEMPERATURE
85 10 (RTH2)
Protection type : Shut down o/p voltage, re-power on to recover
WORKING TEMP.
-40 ~ +70 (Refer to "Derating Curve")
WORKING HUMIDITY
20 ~ 95% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +80 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03%/ (0 ~ 60 )
VIBRATION
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY STANDARDS Note.7 UL8750, EN61347-1, EN61347-2-13 independent ; IP65 or IP67 approved ; Design refer to UL60950-1, TUV EN60950-1
WITHSTAND VOLTAGE
SAFETY &
ISOLATION RESISTANCE
EMC
EMC EMISSION
I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55015, EN61000-3-2 Class C ( 60% load) ; EN61000-3-3
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, EN55024, heavy industry level (surge 4KV), criteria A
MTBF
336.5Khrs min. MIL-HDBK-217F (25 )
OTHERS DIMENSION
171*61.5*36.8mm (L*W*H)
PACKING
0.73Kg; 20pcs/15.6Kg/0.8CUFT
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Constant current operation region is within 60% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
5. Derating may be needed under low input voltages. Please check the static characteristics for more details.
6. Type A only.
7. Safety and EMC design refer to EN60598-1, CNS15233, GB7000.1, FCC part18.
8. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
9. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
File Name:HLG-40H-SPEC 2011-05-30