English
Language : 

HLG-320H Datasheet, PDF (1/7 Pages) Mean Well Enterprises Co., Ltd. – 320W Single Output Switching Power Supply
320W Single Output Switching Power Supply
HLG-320H series
Features :
Universal AC input / Full range (up to 305VAC)
Built-in active PFC function
High efficiency up to 95%
Protections: Short circuit / Over current / Over voltage / Over temperature
Cooling by free air convection
OCP point adjustable through output cable or internal potentiometer
IP67 / IP65 design for indoor or outdoor installations
Three in one dimming function (1~10Vdc or PWM signal or resistance)
Suitable for LED lighting and street lighting applications
Compliance to worldwide safety regulations for lighting
Suitable for dry / damp / wet location
5 years warranty (Note.10)
F 110 M M SELV IP65 IP67
HLG-320H-12 A
Blank : IP67 rated. Cable for I/O connection.
A : IP65 rated. Output voltage and constant current level can be adjusted through internal potentiometer.
B : IP67 rated. Constant current level adjustable through output cable with 1~10Vdc or PWM signal or resistance.
C : Terminal block for I/O connection. Output voltage and constant current level can be adjusted through internal
potentiometer.
D (option) : IP67 rated. Timer dimming function, contact MEAN WELL for details.
SPECIFICATION
MODEL
HLG-320H-12 HLG-320H-15 HLG-320H-20 HLG-320H-24 HLG-320H-30 HLG-320H-36 HLG-320H-42 HLG-320H-48 HLG-320H-54
DC VOLTAGE
12V
15V
CONSTANT CURRENT REGION Note.4 6 ~12V
7.5 ~ 15V
RATED CURRENT
22A
19A
RATED POWER
264W
285W
RIPPLE & NOISE (max.) Note.2 150mVp-p 150mVp-p
VOLTAGE ADJ. RANGE Note.6 10.8 ~ 13.5V 13.5 ~ 17V
20V
10 ~ 20V
15A
300W
150mVp-p
17 ~ 22V
24V
12 ~ 24V
13.34A
320.16W
150mVp-p
21 ~ 26V
30V
15 ~ 30V
10.7A
321W
200mVp-p
26 ~ 32V
36V
18 ~ 36V
8.9A
320.4W
250mVp-p
32 ~ 39V
42V
21 ~ 42V
7.65A
321.3W
250mVp-p
38 ~ 45V
48V
24 ~ 48V
6.7A
321.6W
250mVp-p
43 ~ 52V
54V
27 ~ 54V
5.95A
321.3W
350mVp-p
49 ~ 58V
OUTPUT
CURRENT ADJ. RANGE
Can be adjusted by internal potentiometer or through output cable
11 ~ 22A 9.5 ~ 19A 7.5 ~ 15A 6.67 ~ 13.34A 5.35 ~ 10.7A 4.45 ~ 8.9A
VOLTAGE TOLERANCE Note.3 3.0%
2.0%
1.5%
1.0%
1.0%
1.0%
LINE REGULATION
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
LOAD REGULATION
2.0%
1.5%
1.0%
0.5%
0.5%
0.5%
SETUP, RISE TIME Note.8 2500ms, 80ms at full load 230VAC /115VAC
HOLD UP TIME (Typ.)
15ms at full load 230VAC /115VAC
3.8 ~ 7.65A
1.0%
0.5%
0.5%
3.35 ~ 6.7A
1.0%
0.5%
0.5%
2.97 ~ 5.95A
1.0%
0.5%
0.5%
VOLTAGE RANGE Note.5 90 ~ 305VAC 127 ~ 431VDC
FREQUENCY RANGE
47 ~ 63Hz
INPUT
POWER FACTOR (Typ.)
EFFICIENCY (Typ.) (230Vac)
EFFICIENCY (Typ.) (277Vac)
AC CURRENT (Typ.)
INRUSH CURRENT(Typ.)
PF>0.98/115VAC, PF>0.95/230VAC, PF>0.94/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
91%
92.5%
93.5%
94%
94%
94.5%
95%
95%
95%
91.5%
93%
94%
94.5%
94.5%
95%
95%
95%
95%
3.5A / 115VAC 1.65A / 230VAC 1.45A / 277VAC
COLD START 75A/230VAC
LEAKAGE CURRENT
<0.75mA / 277VAC
OVER CURRENT
95 ~ 108%
Note.4
Protection type : Constant current limiting, recovers automatically after fault condition is removed
SHORT CIRCUIT
PROTECTION
OVER VOLTAGE
Hiccup mode, recovers automatically after fault condition is removed.
14 ~ 17V 17.5 ~ 21V 22.5 ~ 27V 27 ~ 33V 33 ~ 37V 40 ~ 46V
Protection type : Shut down and latch off o/p voltage, re-power on to recover
46.5 ~ 53V 53.5 ~ 60V 59 ~ 65V
OVER TEMPERATURE
100 10 (RTH2)
Protection type : Shut down and latch off o/p voltage, re-power on to recover
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
-40 ~ +70 (Refer to "Derating Curve")
20 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH
0.03%/ (0 ~ 50 )
VIBRATION
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY &
EMC
SAFETY STANDARDS Note.7 UL8750, EN61347-1, EN61347-2-13 independent (except for HLG-320H C type) approved ; Design refer to UL60950-1, TUV EN60950-1
WITHSTAND VOLTAGE
I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
EMC EMISSION
Compliance to EN55015, EN55022 (CISPR22) Class B, EN61000-3-2 Class C ( 50% load) ; EN61000-3-3
EMC IMMUNITY
MTBF
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge 4KV), criteria A
157.1Khrs min. MIL-HDBK-217F (25 )
OTHERS
NOTE
DIMENSION
252*90*43.8mm (L*W*H)(HLG-320H-Blank/A/B/D) 256*90*43.8mm (L*W*H)(HLG-320H-C)
PACKING
1.88Kg; 8pcs/16Kg/0.83CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Constant current operation region is within 50% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
5. Derating may be needed under low input voltages. Please check the static characteristics for more details.
6. Type A and type C only.
7. Safety and EMC design refer to EN60598-1, subject CNS15233, GB7000.1, FCC part18.
8. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
9. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.