English
Language : 

HLG-240_11 Datasheet, PDF (1/6 Pages) Mean Well Enterprises Co., Ltd. – 240W Single Output Switching Power Supply
240W Single Output Switching Power Supply
HLG-240 series
Features :
Universal AC input / Full range
Built-in active PFC function
Protections: Short circuit / Over current / Over voltage / Over temperature
Cooling by free air convection
OCP point adjustable through output cable or internal potentiometer
IP67 / IP65 design for indoor or outdoor installations
Three in one dimming function (1~10Vdc or PWM signal or resistance)
Suitable for LED lighting and street lighting applications
Compliance to worldwide safety regulations for lighting
Suitable for dry / damp / wet locations
5 years warranty (Note.10)
F 110 SELV IP65 IP67
HLG-240-12 A
Blank : IP67 rated. Cable for I/O connection.
A : IP65 rated. Output voltage and constant current level can be adjusted through internal potentiometer.
B : IP67 rated. Constant current level adjustable through output cable with 1~10Vdc or 10V PWM signal or resistance.
C : Terminal block for I/O connection. Output voltage and constant current level can be adjusted through internal
potentiometer.
SPECIFICATION
MODEL
HLG-240-12 HLG-240-15 HLG-240-20 HLG-240-24 HLG-240-30 HLG-240-36 HLG-240-42 HLG-240-48 HLG-240-54
OUTPUT
DC VOLTAGE
12V
15V
20V
24V
30V
CONSTANT CURRENT REGION Note.4 6 ~12V
7.5 ~ 15V 10 ~ 20V 12 ~ 24V 15 ~ 30V
RATED CURRENT
16A
15A
12A
10A
8A
RATED POWER
192W
225W
240W
240W
240W
RIPPLE & NOISE (max.) Note.2 150mVp-p 150mVp-p 150mVp-p 150mVp-p 200mVp-p
VOLTAGE ADJ. RANGE Note.6 11.2 ~ 12.8V 14 ~ 16V 18.6 ~ 21.4V 22.4 ~ 25.6V 28 ~ 32V
CURRENT ADJ. RANGE
Can be adjusted by internal potentiometer or through output cable
8 ~ 16A
7.5 ~ 15A 6 ~ 12A
5 ~ 10A
4 ~ 8A
VOLTAGE TOLERANCE Note.3 2.5%
2.0%
1.0%
1.0%
1.0%
LINE REGULATION
0.5%
0.5%
0.5%
0.5%
0.5%
LOAD REGULATION
2.0%
1.5%
1.0%
0.5%
0.5%
SETUP, RISE TIME Note.8 2500ms, 80ms at full load 230VAC /115VAC
HOLD UP TIME (Typ.)
15ms at full load 230VAC /115VAC
36V
42V
18 ~ 36V 21 ~ 42V
6.7A
5.72A
241.2W
240.2W
250mVp-p 250mVp-p
33.5 ~ 38.5V 39 ~ 45V
48V
54V
24 ~ 48V 27 ~ 54V
5A
4.45A
240W
240.3W
250mVp-p 350mVp-p
44.8 ~ 51.2V 50 ~ 57V
3.3 ~ 6.7A
1.0%
0.5%
0.5%
2.86 ~ 5.72A 2.5 ~ 5A
1.0%
1.0%
0.5%
0.5%
0.5%
0.5%
2.23 ~ 4.45A
1.0%
0.5%
0.5%
VOLTAGE RANGE Note.5 90 ~ 264VAC 127 ~ 373VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.98/115VAC, PF>0.95/230VAC at full load (Please refer to "Power Factor Characteristic" curve)
INPUT EFFICIENCY (Typ.)
90%
90%
92%
93%
93%
93.5%
94%
94%
94%
AC CURRENT (Typ.)
4A / 115VAC 2A / 230VAC
INRUSH CURRENT (Typ.) COLD START 75A/230VAC
LEAKAGE CURRENT
<0.75mA / 240VAC
OVER CURRENT
95 ~ 108%
Note.4
Protection type : Constant current limiting, recovers automatically after fault condition is removed
SHORT CIRCUIT
PROTECTION
OVER VOLTAGE
Hiccup mode, recovers automatically after fault condition is removed.
13.5 ~ 18V 17.5 ~ 21.5V 23.5 ~ 27.5V 27 ~ 34V 33 ~ 39V 43 ~ 49V
Protection type : Shut down and latch off o/p voltage, re-power on to recover
48 ~ 54V
55 ~ 63V
58 ~ 65V
OVER TEMPERATURE
105 5 (TSW1)
95 5 (TSW1)
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
-40 ~ +70 (Refer to "Derating Curve")
20 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH
0.03%/ (0 ~ 50 )
VIBRATION
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY &
EMC
UL1012, TUV EN61347-1, EN61347-2-13 independent (except for HLG-240 C type), UL60950-1, UL8750, TUV EN60950-1,
SAFETY STANDARDS Note.7
J61347-1, J61347-2-13, IP65 or IP67 approved
WITHSTAND VOLTAGE
I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
EMC EMISSION
Compliance to EN55015, EN55022 (CISPR22) Class B, EN61000-3-2 Class C ( 50% load) ; EN61000-3-3
OTHERS
NOTE
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, heavy industry level (surge 4KV), criteria A
MTBF
207.9Khrs min. MIL-HDBK-217F (25 )
DIMENSION
244.2*68*38.8mm (L*W*H)(HLG-240-Blank/A/B) 251*68*38.8mm (L*W*H)(HLG-240-C)
PACKING
1.3Kg; 12pcs/16.6Kg/0.78CUFT(HLG-240-Blank/A/B) 1.23Kg; 12pcs/15.8Kg/1.16CUFT(HLG-240-C)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Constant current operation region is within 50% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
5. Derating may be needed under low input voltages. Please check the static characteristics for more details.
6. Type A and type C only.
7. Safety and EMC design refer to EN60598-1, subject 8750(UL), CNS15233, GB7000.1, FCC part18.
8. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
9. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
10. Refer to warranty statement.