English
Language : 

HLG-240H_12 Datasheet, PDF (1/6 Pages) Mean Well Enterprises Co., Ltd. – 240W Single Output Switching Power Supply
240W Single Output Switching Power Supply
HLG-240H series
Features :
Universal AC input / Full range (up to 305VAC)
Built-in active PFC function
Protections: Short circuit / Over current / Over voltage / Over temperature
Cooling by free air convection
OCP point adjustable through output cable or internal potentiometer
IP67 / IP65 design for indoor or outdoor installations
Three in one dimming function (1~10Vdc or PWM signal or resistance)
Suitable for LED lighting and street lighting applications
Compliance to worldwide safety regulations for lighting
Suitable for dry / damp / wet locations
5 years warranty (Note.10)
F 110 SELV IP65 IP67
HLG-240H-12 A
Blank : IP67 rated. Cable for I/O connection.
A : IP65 rated. Output voltage and constant current level can be adjusted through internal potentiometer.
B : IP67 rated. Constant current level adjustable through output cable with 1~10Vdc or 10V PWM signal or resistance.
C : Terminal block for I/O connection. Output voltage and constant current level can be adjusted through internal
potentiometer.
D (option) : IP67 rated. Timer dimming function, contact MEAN WELL for details.
SPECIFICATION
MODEL
HLG-240H-12 HLG-240H-15 HLG-240H-20 HLG-240H-24 HLG-240H-30 HLG-240H-36 HLG-240H-42 HLG-240H-48 HLG-240H-54
DC VOLTAGE
12V
15V
CONSTANT CURRENT REGION Note.4 6 ~12V
7.5 ~ 15V
RATED CURRENT
16A
15A
RATED POWER
192W
225W
RIPPLE & NOISE (max.) Note.2 150mVp-p 150mVp-p
VOLTAGE ADJ. RANGE Note.6 11.2 ~ 12.8V 14 ~ 16V
20V
24V
30V
10 ~ 20V 12 ~ 24V 15 ~ 30V
12A
10A
8A
240W
240W
240W
150mVp-p 150mVp-p 200mVp-p
18.6 ~ 21.4V 22.4 ~ 25.6V 28 ~ 32V
36V
42V
18 ~ 36V 21 ~ 42V
6.7A
5.72A
241.2W
240.24W
250mVp-p 250mVp-p
33.5 ~ 38.5V 39 ~ 45V
48V
54V
24 ~ 48V 27 ~ 54V
5A
4.45A
240W
240.3W
250mVp-p 350mVp-p
44.8 ~ 51.2V 50 ~ 57V
OUTPUT
CURRENT ADJ. RANGE
Can be adjusted by internal potentiometer or through output cable
8 ~ 16A
7.5 ~ 15A 6 ~ 12A
5 ~ 10A
4 ~ 8A
VOLTAGE TOLERANCE Note.3 2.5%
2.0%
1.0%
1.0%
1.0%
LINE REGULATION
0.5%
0.5%
0.5%
0.5%
0.5%
LOAD REGULATION Note.8 2.0%
1.5%
1.0%
0.5%
0.5%
SETUP, RISE TIME Note.9 2500ms, 80ms at full load 230VAC /115VAC
3.3 ~ 6.7A
1.0%
0.5%
0.5%
2.86 ~ 5.72A 2.5 ~ 5A
1.0%
1.0%
0.5%
0.5%
0.5%
0.5%
2.23 ~ 4.45A
1.0%
0.5%
0.5%
HOLD UP TIME (Typ.)
15ms at full load 230VAC /115VAC
VOLTAGE RANGE Note.5 90 ~ 305VAC 127 ~ 431VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.98/115VAC, PF>0.95/230VAC at full load (Please refer to "Power Factor Characteristic" curve)
INPUT EFFICIENCY (Typ.)
90%
90%
92%
93%
93%
93%
93%
93.5%
94%
AC CURRENT (Typ.)
4A / 115VAC 2A / 230VAC 1.2A / 277VAC
INRUSH CURRENT (Typ.) COLD START 75A/230VAC
LEAKAGE CURRENT
<0.75mA / 277VAC
OVER CURRENT
SHORT CIRCUIT
PROTECTION
OVER VOLTAGE
95 ~ 108%
Note.4
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Hiccup mode, recovers automatically after fault condition is removed
13.5 ~ 18V 17.5 ~ 21.5V 23.5 ~ 27.5V 27 ~ 34V 33 ~ 39V 43 ~ 49V 48 ~ 54V
Protection type : Shut down and latch off o/p voltage, re-power on to recover
55 ~ 63V
60 ~ 67V
OVER TEMPERATURE
105 5 (TSW1)
95 5 (TSW1)
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
-40 ~ +70 (Refer to "Derating Curve")
20 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH
0.03%/ (0 ~ 50 )
VIBRATION
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
UL1012, CAN/CSA-C22.2 No. 107.1-01, UL8750, CSA C22.2 No. 250.0-08, TUV EN61347-1, EN61347-2-13 independent
SAFETY STANDARDS Note.7
(except for HLG-240H C type), UL60950-1, UL8750, TUV EN60950-1, IP65 or IP67 approved, J61347-1, J61347-2-13
SAFETY & WITHSTAND VOLTAGE
EMC
ISOLATION RESISTANCE
EMC EMISSION
I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55015, EN55022 (CISPR22) Class B, EN61000-3-2 Class C ( 50% load) ; EN61000-3-3
EMC IMMUNITY
MTBF
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge 4KV), criteria A
207.9Khrs min. MIL-HDBK-217F (25 )
OTHERS
NOTE
DIMENSION
244.2*68*38.8mm (L*W*H)(HLG-240H-Blank/A/B) 251*68*38.8mm (L*W*H)(HLG-240H-C)
PACKING
1.3Kg; 12pcs/16.6Kg/0.84CUFT(HLG-240-Blank/A/B) 1.23Kg; 12pcs/15.8Kg/1.16CUFT(HLG-240-C)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Constant current operation region is within 50% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
5. Derating may be needed under low input voltages. Please check the static characteristics for more details.
6. Type A and type C only.
7. Safety and EMC design refer to EN60598-1, subject 8750(UL), CNS15233, GB7000.1, FCC part18.
8. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
9. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
10. Refer to warranty statement.