English
Language : 

HLG-185H Datasheet, PDF (1/6 Pages) Mean Well Enterprises Co., Ltd. – 185W Single Output Switching Power Supply
185W Single Output Switching Power Supply
HLG-185H series
Features :
Universal AC input / Full range (up to 305VAC)
Built-in active PFC function
High efficiency up to 94%
Protections: Short circuit / Overload / Over voltage / Over temperature
Cooling by free air convection
OCP point adjustable through output cable or internal potential meter
IP67 / IP65 design for indoor or outdoor installations
Three in one dimming function (1~10Vdc or PWM signal or resistor)
Suitable for LED lighting and street lighting applications
Compliance to worldwide safety regulations for lighting
Suitable for dry / damp / wet locations
5 years warranty (Note.10)
F 110 M M SELV IP65 IP67
HLG-185H-12 A
Blank : IP67 rated. Cable for I/O connection.
A : IP65 rated. Output voltage and constant current level can be adjusted through internal potential meter.
B : IP67 rated. Constant current level adjustable through output cable with 1~10Vdc or 10V PWM signal or resistor.
SPECIFICATION
MODEL
HLG-185H-12 HLG-185H-15 HLG-185H-20 HLG-185H-24 HLG-185H-30 HLG-185H-36 HLG-185H-42 HLG-185H-48 HLG-185H-54
OUTPUT
DC VOLTAGE
12V
15V
20V
24V
30V
CONSTANT CURRENT REGION Note.4 6 ~12V
7.5 ~ 15V 10 ~ 20V 12 ~ 24V 15 ~ 30V
RATED CURRENT
13A
11.5A
9.3A
7.8A
6.2A
RATED POWER
156W
172W
186W
187.2W
186W
RIPPLE & NOISE (max.) Note.2 150mVp-p 150mVp-p 150mVp-p 150mVp-p 200mVp-p
VOLTAGE ADJ. RANGE Note.6 10.8 ~ 13.5V 13.5 ~ 17V 17 ~ 22V 22 ~ 27V 27 ~ 33V
CURRENT ADJ. RANGE
Can be adjusted by internal potential meter or through output cable
6.5 ~ 13A 5.75 ~ 11.5A 4.65 ~ 9.3A 3.9 ~ 7.8A 3.1 ~ 6.2A
VOLTAGE TOLERANCE Note.3 2.5%
2.0%
1.0%
1.0%
1.0%
LINE REGULATION
0.5%
0.5%
0.5%
0.5%
0.5%
LOAD REGULATION
2.0%
1.5%
1.0%
0.5%
0.5%
36V
18 ~ 36V
5.2A
187.2W
200mVp-p
33 ~ 40V
2.6 ~ 5.2A
1.0%
0.5%
0.5%
42V
21 ~ 42V
4.4A
184.8W
200mVp-p
38 ~ 46V
2.2 ~ 4.4A
1.0%
0.5%
0.5%
48V
24 ~ 48V
3.9A
187.2W
200mVp-p
43 ~ 53V
54V
27 ~ 54V
3.45A
186.3W
200mVp-p
49 ~ 58V
1.95 ~ 3.9A
1.0%
0.5%
0.5%
1.72 ~ 3.45A
1.0%
0.5%
0.5%
SETUP, RISE TIME Note.8 2500ms, 80ms at full load 230VAC / 115VAC ; B type 2500ms, 200ms at 95% load 230VAC / 115VAC
HOLD UP TIME (Typ.)
16ms at full load 230VAC / 115VAC
VOLTAGE RANGE Note.5 90 ~ 305VAC
FREQUENCY RANGE
47 ~ 63Hz
127 ~ 431VDC
POWER FACTOR
PF 0.95/230VAC PF 0.98/115VAC at full load and rated output voltage PF 0.9 at 50 ~ 100% load
EFFICIENCY (Typ.)
91.5%
92%
93%
93.5%
93.5%
93.5%
94%
94%
94%
INPUT
12V
1.8A / 115VAC 0.8A / 230VAC 0.7A / 277VAC
AC CURRENT
15V ~ 54V 2.1A / 115VAC 0.9A / 230VAC 0.8A / 277VAC
INRUSH CURRENT(Typ.)
COLD START 75A/230VAC
LEAKAGE CURRENT
<0.75mA / 277VAC
OVER CURRENT
SHORT CIRCUIT
PROTECTION OVER VOLTAGE
95 ~ 108%
Note.4
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Constant current limiting, recovers automatically after fault condition is removed
14 ~ 17V 18 ~ 21V 23 ~ 27V 28 ~ 34V 34 ~ 38V 41 ~ 46V 47 ~ 53V
Protection type : Shut down o/p voltage with auto-recovery or re-power on to recovery
54 ~ 60V
59 ~ 65V
OVER TEMPERATURE
100 10 (RTH2)
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
-40 ~ +60 @ full load ; +70 @ 60% load (Refer to derating curve)
20 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH
0.03%/ (0 ~ 50 )
VIBRATION
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY STANDARDS Note.7 EN61347-1, EN61347-2-13 independent IP65 or IP67 approved ; Design refer to UL60950-1, TUV EN60950-1
SAFETY &
EMC
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55015, EN55022 (CISPR22) Class B
Compliance to EN61000-3-2 Class C ( 50% load) ; EN61000-3-3
OTHERS
NOTE
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61547, EN55024, heavy industry level (surge 4KV), criteria A
MTBF
192.2Khrs min. MIL-HDBK-217F (25 )
DIMENSION
228*68*38.8mm (L*W*H)
PACKING
1.15Kg; 12pcs/14.8Kg/0.76CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Constant current operation region is within 50% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
5. Derating may be needed under low input voltages. Please check the static characteristics for more details.
6. Type A only.
7. Safety and EMC design refer to EN60598-1, CNS15233, GB7000.1, FCC part18.
8. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
9. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
10. Refer to warranty statement.