English
Language : 

HLG-150 Datasheet, PDF (1/6 Pages) Mean Well Enterprises Co., Ltd. – 150W Single Output Switching Power Supply
150W Single Output Switching Power Supply
HLG-150 series
Features :
Universal AC input / Full range
Built-in active PFC function
High efficiency up to 94%
Protections: Short circuit / Overload / Over voltage / Over temperature
Cooling by free air convection
OCP point adjustable through output cable or internal potential meter
IP67 / IP65 design for indoor or outdoor installations
Three in one dimming function (1~10Vdc or PWM signal or resistor)
Suitable for LED lighting and street lighting applications
Compliance to worldwide safety regulations for lighting
Suitable for dry / damp / wet locations
5 years warranty (Note.10)
F 110 M M SELV IP65 IP67
HLG-150-12 A
Blank : IP67 rated. Cable for I/O connection.
A : IP65 rated. Output voltage and constant current level can be adjusted through internal potential meter.
B : IP67 rated. Constant current level adjustable through output cable with 1~10Vdc or 10V PWM signal or resistor.
SPECIFICATION
MODEL
HLG-150-12 HLG-150-15 HLG-150-20 HLG-150-24 HLG-150-30 HLG-150-36 HLG-150-42 HLG-150-48 HLG-150-54
DC VOLTAGE
12V
15V
CONSTANT CURRENT REGION Note.4 6 ~12V
7.5 ~ 15V
RATED CURRENT
12.5A
10A
RATED POWER
150W
150W
RIPPLE & NOISE (max.) Note.2 150mVp-p 150mVp-p
VOLTAGE ADJ. RANGE Note.6 10.8 ~ 13.5V 13.5 ~ 17V
20V
10 ~ 20V
7.5A
150W
150mVp-p
17 ~ 22V
24V
12 ~ 24V
6.3A
151.2W
150mVp-p
22 ~ 27V
30V
15 ~ 30V
5A
150W
200mVp-p
27 ~ 33V
36V
18 ~ 36V
4.2A
151.2W
200mVp-p
33 ~ 40V
42V
21 ~ 42V
3.6A
151.2W
200mVp-p
38 ~ 46V
48V
24 ~ 48V
3.2A
153.6W
200mVp-p
43 ~ 53V
54V
27 ~ 54V
2.8A
151.2W
200mVp-p
49 ~ 58V
OUTPUT
CURRENT ADJ. RANGE
Can be adjusted by internal potential meter or through output cable
7.5 ~ 12.5A 6 ~ 10A
4.5 ~ 7.5A 3.8 ~ 6.3A 3 ~ 5A
2.5 ~ 4.2A
VOLTAGE TOLERANCE Note.3 2.5%
2.0%
1.0%
1.0%
1.0%
1.0%
LINE REGULATION
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
LOAD REGULATION
2.0%
1.5%
1.0%
0.5%
0.5%
0.5%
SETUP, RISE TIME Note.8 2500ms, 80ms at full load 230VAC / 115VAC ; B type 2500ms, 200ms at 95% load
HOLD UP TIME (Typ.)
16ms at full load 230VAC / 115VAC
2.16 ~ 3.6A 1.92 ~ 3.2A
1.0%
1.0%
0.5%
0.5%
0.5%
0.5%
230VAC / 115VAC
1.68 ~ 2.8A
1.0%
0.5%
0.5%
VOLTAGE RANGE Note.5 90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR
PF 0.95/230VAC PF 0.98/115VAC at full load and rated output voltage
PF 0.9 at 60 ~ 100% load
INPUT EFFICIENCY (Typ.)
92%
92.5%
93%
93.5%
93.5%
93.5%
94%
94%
94%
AC CURRENT
1.7A / 115VAC 0.75A / 230VAC
INRUSH CURRENT(Typ.)
COLD START 75A/230VAC
LEAKAGE CURRENT
<0.75mA / 240VAC
OVER CURRENT
SHORT CIRCUIT
PROTECTION
OVER VOLTAGE
95 ~ 108%
Note.4
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Constant current limiting, recovers automatically after fault condition is removed
14 ~ 17V 18 ~ 21V 23 ~ 27V 28 ~ 34V 34 ~ 38V 41 ~ 46V 47 ~ 53V
Protection type : Shut down o/p voltage with auto-recovery or re-power on to recovery
54 ~ 60V
59 ~ 65V
OVER TEMPERATURE
100 10 (RTH2)
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
-40 ~ +60 @ full load ; +70 @ 60% load (Refer to derating curve)
20 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH
0.03%/ (0 ~ 50 )
VIBRATION
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY STANDARDS Note.7 EN61347-1, EN61347-2-13 independent IP65 or IP67 approved ; Design refer to UL60950-1, TUV EN60950-1
WITHSTAND VOLTAGE
I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC
SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
EMC
EMI CONDUCTION & RADIATION Compliance to EN55015, EN55022 (CISPR22) Class B
HARMONIC CURRENT
Compliance to EN61000-3-2 Class C ( 60% load) ; EN61000-3-3
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61547, EN55024, heavy industry level (surge 4KV), criteria A
MTBF
192.2Khrs min. MIL-HDBK-217F (25 )
OTHERS DIMENSION
228*68*38.8mm (L*W*H)
PACKING
1.15Kg; 12pcs/14.8Kg/0.76CUFT
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Constant current operation region is within 60% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
5. Derating may be needed under low input voltages. Please check the static characteristics for more details.
6. Type A only.
7. Safety and EMC design refer to EN60598-1, CNS15233, GB7000.1, FCC part18.
8. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
9. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
10. Refer to warranty statement.