English
Language : 

HLG-120H_1107 Datasheet, PDF (1/6 Pages) Mean Well Enterprises Co., Ltd. – 120W Single Output Switching Power Supply
120W Single Output Switching Power Supply
HLG-120H series
Features :
Universal AC input / Full range (up to 305VAC)
Built-in active PFC function
High efficiency up to 93.5%
Protections: Short circuit / Over current / Over voltage / Over temperature
Cooling by free air convection
OCP point adjustable through output cable or internal potentiometer
IP67 / IP65 design for indoor or outdoor installations
Three in one dimming function (1~10Vdc or PWM signal or resistance)
Suitable for LED lighting and street lighting applications
Compliance to worldwide safety regulations for lighting
Suitable for dry / damp / wet locations
5 years warranty (Note.9)
F 110 M M SELV IP65 IP67
HLG-120H-12 A
Blank : IP67 rated. Cable for I/O connection.
A : IP65 rated. Output voltage and constant current level can be adjusted through internal potentiometer.
B : IP67 rated. Constant current level adjustable through output cable with 1~10Vdc or 10V PWM signal or resistance.
D (option) : IP67 rated. Timer dimming function, contact MEAN WELL for details.
SPECIFICATION
MODEL
HLG-120H-12 HLG-120H-15 HLG-120H-20 HLG-120H-24 HLG-120H-30 HLG-120H-36 HLG-120H-42 HLG-120H-48 HLG-120H-54
DC VOLTAGE
12V
15V
RATED CURRENT
10A
8A
RATED POWER
120W
120W
RIPPLE & NOISE (max.) Note.2 150mVp-p 150mVp-p
VOLTAGE ADJ. RANGE Note.5 10.8 ~ 13.5V 13.5 ~ 17V
20V
6A
120W
150mVp-p
17 ~ 22V
24V
5A
120W
150mVp-p
22 ~ 27V
30V
4A
120W
200mVp-p
27 ~ 33V
36V
3.4A
122.4W
200mVp-p
33 ~ 40V
42V
2.9A
121.8W
200mVp-p
38 ~ 46V
48V
2.5A
120W
200mVp-p
43 ~ 53V
54V
2.3A
124.2W
200mVp-p
49 ~ 58V
OUTPUT
CURRENT ADJ. RANGE
Can be adjusted by internal potentiometer or through output cable
5 ~ 10A
4 ~ 8A
3 ~ 6A
2.5 ~ 5A 2 ~ 4A
1.7 ~ 3.4A
VOLTAGE TOLERANCE Note.3 2.5%
2.0%
1.0%
1.0%
1.0%
1.0%
LINE REGULATION
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
LOAD REGULATION
2.0%
1.5%
0.5%
0.5%
0.5%
0.5%
SETUP, RISE TIME Note.7 2500ms, 50ms at full load 230VAC / 115VAC ; B type 2500ms, 200ms at 95% load
HOLD UP TIME (Typ.)
12ms at full load 230VAC / 115VAC
1.4 ~ 2.9A 1.2 ~ 2.5A
1.0%
1.0%
0.5%
0.5%
0.5%
0.5%
230VAC / 115VAC
1.1 ~ 2.3A
1.0%
0.5%
0.5%
VOLTAGE RANGE Note.4 90 ~ 305VAC 127 ~ 431VDC
INPUT
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
47 ~ 63Hz
PF>0.98/115VAC, PF>0.95/230VAC, PF>0.93/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
92%
92%
93%
93%
93%
93%
93%
93.5%
93.5%
1.4A / 115VAC 0.6A / 230VAC 0.55A / 277VAC
COLD START 75A/230VAC
LEAKAGE CURRENT
<0.75mA / 277VAC
OVER CURRENT
SHORT CIRCUIT
PROTECTION
OVER VOLTAGE
95 ~ 108%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Constant current limiting, recovers automatically after fault condition is removed
14 ~ 17V 18 ~ 21V 23 ~ 27V 28 ~ 34V 34 ~ 38V 41 ~ 46V 47 ~ 53V
Protection type : Shut down o/p voltage with auto-recovery or re-power on to recovery
54 ~ 60V
59 ~ 65V
OVER TEMPERATURE
85 10 (RTH2)
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
-40 ~ +70 (Refer to "Derating Curve")
20 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH
0.03%/ (0 ~ 50 )
VIBRATION
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY STANDARDS Note.6 UL8750, EN61347-1, EN61347-2-13 independent, J61347-1, J61347-2-13, IP65 or IP67 approved ; Design refer to UL60950-1, TUV EN60950-1
WITHSTAND VOLTAGE
SAFETY &
EMC
ISOLATION RESISTANCE
EMC EMISSION
I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55015, EN55022 (CISPR22) Class B, EN61000-3-2 Class C ( 50% load) ; EN61000-3-3
EMC IMMUNITY
MTBF
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, heavy industry level (surge 4KV), criteria A
192.2Khrs min. MIL-HDBK-217F (25 )
OTHERS
NOTE
DIMENSION
220*68*38.8mm (L*W*H)
PACKING
1.12Kg; 12pcs/14.4Kg/0.74CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltages. Please check the static characteristics for more details.
5. Type A only.
6. Safety and EMC design refer to EN60598-1, CNS15233, GB7000.1, FCC part18.
7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
9. Refer to warranty statement.
File Name:HLG-120H-SPEC 2011-07-28