240W Dual Output with PFC Function
HDP-240
Features :
Universal AC input / Full range
Built-in active PFC function, PF 0.94
High efficiency up to 84%
Protections: Short circuit / Overload / Over voltage / Over temperature
Forced air cooling by built-in DC fan
1U low profile 36mm
Conformal coated
Built-in cooling fan ON-OFF control
ZVS technology to reduce power dissipation
LED indicator for power on
3 years warranty
SPECIFICATION
MODEL
HDP-240
OUTPUT NUMBER
V1
V2
DC VOLTAGE
RATED CURRENT
CURRENT RANGE (max.)
+3.8V
41.5A
0 ~ 50A
+2.8V
25A
0 ~ 27.5A
RATED POWER
227.7W (typ.) 241W (max.)
OUTPUT
OUTPUT POWER (max.)
241W continue. V1 total power output shall not exceed 200W (max. 50A) ; V2 total power output shall not exceed 82.5W (max. 27.5A)
(The V1 & V2 combine total power output shall not exceed 241W)
RIPPLE & NOISE (max.) Note.2 100mVp-p
100mVp-p
VOLTAGE ADJ. RANGE Note.6 3.6 ~ 4V
2.5 ~ 3V
VOLTAGE TOLERANCE Note.3 2.0%
2.0%
LINE REGULATION
0.5%
0.5%
LOAD REGULATION
2.0%
2.0%
SETUP, RISE TIME
1000ms, 50ms/230VAC 2500ms, 50ms/115VAC at full load
HOLD UP TIME (Typ.)
16ms/230VAC 16ms/115VAC at full load
INPUT
VOLTAGE RANGE Note.5 90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF 0.94/230VAC PF 0.98/115VAC at full load
EFFICIENCY (Typ.)
84%
AC CURRENT (Typ.)
3.3A/115VAC 1.3A/230VAC
INRUSH CURRENT (Typ.) 30A/115VAC 45A/230VAC
LEAKAGE CURRENT
<2mA / 240VAC
OVERLOAD
V1+V2: 105 ~ 150% max. output power ; or V2: 125 ~ 170% rated current
Protection type: Hiccup mode, recovers automatically after fault condition is removed
PROTECTION OVER VOLTAGE
V1: 4.37 ~ 5.13V
V2: 3.22 ~ 3.78V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE
80 5 (TSW1) detect on heatsink of power transistor
Protection type : Shut down o/p voltage, re-power on to recovery
FUNCTION FAN CONTROL (Typ.)
RTH4 50 Fan on ; RTH4 45 Fan off
WORKING TEMP.
-30 ~ +70 (Refer to "Derating Curve")
WORKING HUMIDITY
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03%/ (0 ~ 50 )
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL60950-1, TUV EN60950-1 approved
SAFETY & WITHSTAND VOLTAGE
EMC
(Note 4)
ISOLATION RESISTANCE
EMC EMISSION
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) class B, EN61000-3-2,-3
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2, heavy industry level, criteria A
MTBF
111.3K hrs min. MIL-HDBK-217F (25 )
OTHERS DIMENSION
PACKING
215*115*36mm (L*W*H)
1Kg; 15pcs/16Kg/0.7CUFT
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
6. Output voltage between V1 and V2 should be higher than 0.8V(V1-V2 0.8V).
File Name:HDP-240-SPEC 2011-12-28