English
Language : 

GS90 Datasheet, PDF (1/2 Pages) Mean Well Enterprises Co., Ltd. – 90WAC-DC Single Output Desktop
90W AC-DC Single Output Desktop
GS90 series
Features :
Universal AC input / Full range
3 pole AC inlet IEC320-C14
Built-in active PFC function, PF>0.91
Protections: Short circuit / Overload / Over voltage / Over temperature
Fully enclosed plastic case
Approvals: UL / CUL / TUV / BSMI / CB / FCC / CE
Class power ( with earth pin)
Pass LPS
LED indicator for power on
No load power consumption<0.5W
Meet EISA 2007(Energy Independence and Security Act)
2 years warranty
SPECIFICATION
(except for 48V)
TUV
Rheinland
Product Safety
geprUfre
Sicherheit
ORDER NO.
GS90A12-P1M
GS90A15-P1M
GS90A19-P1M
GS90A24-P1M
GS90A48-P1M
OUTPUT
INPUT
SAFETY MODEL NO.
GS90A12
GS90A15
GS90A19
DC VOLTAGE
Note.2 12V
15V
19V
RATED CURRENT
6.67A
6A
4.74A
CURRENT RANGE
0 ~ 6.67A
0 ~ 6A
0 ~ 4.74A
RATED POWER (max.)
80W
90W
90W
RIPPLE & NOISE (max.) Note.3 80mVp-p
100mVp-p
150mVp-p
VOLTAGE TOLERANCE Note.4 5.0%
5.0%
4.0%
LINE REGULATION Note.5 1.0%
1.0%
1.0%
LOAD REGULATION Note.6 5.0%
5.0%
4.0%
SETUP, RISE TIME Note.8 1000ms, 20ms / 230VAC 1000ms, 20ms / 115VAC at full load
HOLD UP TIME (Typ.)
20ms / 230VAC 20ms / 115VAC at full load
VOLTAGE RANGE
Note.9 90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.91 / 230VAC PF>0.95 / 115VAC at full load
EFFICIENCY (Typ.)
88%
89%
89%
AC CURRENT (Typ.)
2A / 115VAC 1A / 230VAC
INRUSH CURRENT (max.) 70A / 230VAC
LEAKAGE CURRENT(max.) 1mA / 240VAC
GS90A24
24V
3.75A
0 ~ 3.75A
90W
180mVp-p
3.0%
1.0%
3.0%
89.5%
GS90A48
48V
1.87A
0 ~ 1.87A
90W
240mVp-p
2.0%
1.0%
2.0%
91%
OVERLOAD
PROTECTION OVER VOLTAGE
110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
105 ~ 135% rated output voltage
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE
RTH30 > 100
Protection type : Shut down o/p voltage, re-power on to recover
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
EMC
ISOLATION RESISTANCE
(Note. 7) EMC EMISSION
EMC IMMUNITY
-30 ~ +50 (Refer to "Derating Curve")
20% ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH
0.03% / (0~50 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1, BSMI CNS14336, J60950-1(except for 48V) approved
I/P-O/P: 3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 class B, EN61000-3-2,3, FCC PART 15 / CISPR22 class B, CNS13438 class B, GB17625.1
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
OTHERS
CONNECTOR
MTBF
DIMENSION
PACKING
PLUG
CABLE
348.7Khrs min. MIL-HDBK-217F(25 )
145*60*32mm (L*W*H)
0.45Kg; 30pcs/14.05Kg/1CUFT
Standard type P1M: 2.5 * 5.5 * 11mm, tuning fork type, center positive for stock ; Other type available by customer requested
See page 2 ; Other type available by customer requested
NOTE
1. All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.
2. DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3. Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4. Tolerance: includes set up tolerance, line regulation, load regulation.
5. Line regulation is measured from low line to high line at rated load.
6. Load regulation is measured from 10% to 100% rated load
7. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives.
8. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
9. Derating may be needed under low input voltages. Pleas check the derating curve for more details.
File Name:GS90-SPEC 2011-06-15