English
Language : 

GS60 Datasheet, PDF (1/2 Pages) Mean Well Enterprises Co., Ltd. – 60WAC-DC Single Output Desktop
60W AC-DC Single Output Desktop
GS60 series
Features :
Universal AC input / Full range
3 pole AC inlet IEC320-C14
Protections: Short circuit / Overload / Over voltage/ Over temperature
Fully enclosed plastic case
Approvals: UL / CUL / TUV / BSMI / CB / FCC / CE
Class power ( with earth pin)
Pass LPS
LED indicator for power on
No load power consumption<0.3W
Meet EISA 2007(Energy Independence and Security Act)
2 years warranty
SPECIFICATION
(except for 48V)
TUV
Rheinland
Product Safety
geprUfre
Sicherheit
ORDER NO.
GS60A05-P1J GS60A07-P1J GS60A09-P1J GS60A12-P1J GS60A15-P1J GS60A18-P1J GS60A24-P1J GS60A48-P1J
SAFETY MODEL NO.
GS60A05
GS60A07
GS60A09
GS60A12
GS60A15
GS60A18
GS60A24
GS60A48
DC VOLTAGE
Note.2 5V
7.5V
9V
12V
15V
18V
24V
48V
RATED CURRENT
6A
6A
6A
5A
4A
3.33A
2.5A
1.25A
CURRENT RANGE
0 ~ 6A
0 ~ 6A
0 ~ 6A
0 ~ 5A
0 ~ 4A
0 ~ 3.33A
0 ~ 2.5A
0 ~ 1.25A
RATED POWER (max.)
30W
45W
54W
60W
60W
60W
60W
60W
OUTPUT RIPPLE & NOISE (max.) Note.3 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 150mVp-p 180mVp-p 240mVp-p
VOLTAGE TOLERANCE Note.4 5.0%
5.0%
5.0%
3.0%
3.0%
3.0%
3.0%
2.5%
LINE REGULATION Note.5 1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
LOAD REGULATION
5.0%
5.0%
5.0%
3.0%
3.0%
3.0%
3.0%
2.5%
SETUP, RISE TIME Note.7 1000ms, 30ms / 230VAC 1000ms, 30ms / 115VAC at full load
HOLD UP TIME (Typ.)
50ms / 230VAC 15ms / 115VAC at full load
VOLTAGE RANGE
90 ~ 264VAC 135 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.)
81%
85.5%
87.5%
88%
88.5%
88.5%
90%
92%
INPUT
AC CURRENT (Typ.)
1.4A / 115VAC 1A / 230VAC
INRUSH CURRENT (max.) 65A / 230VAC
LEAKAGE CURRENT(max.) 0.75mA / 240VAC
OVERLOAD
105 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
PROTECTION OVER VOLTAGE
5.25 ~ 6.75V 7.88 ~ 10.13V 9.45 ~ 12.15V 12.6 ~ 16.2V 15.75 ~ 20.25V 18.9 ~ 24.3V 25.2 ~ 32.4V 50.4 ~ 64.8V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE
RTH2 > 70
Protection type : Shut down o/p voltage, re-power on to recover
WORKING TEMP.
-30 ~ +50 (Refer to "Derating Curve")
WORKING HUMIDITY
20% ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03% / (0 ~ 50 )
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL60950-1, TUV EN60950-1, BSMI CNS14336, J60950-1(except for 48V) approved
SAFETY & WITHSTAND VOLTAGE
EMC
ISOLATION RESISTANCE
(Note. 6) EMC EMISSION
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 class B, EN61000-3-2,3, FCC PART 15 / CISPR22 class B, CNS13438 class B, GB17625.1
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
MTBF
711Khrs min. MIL-HDBK-217F(25 )
OTHERS DIMENSION
PACKING
125*50*31.5mm (L*W*H)
0.305Kg; 40pcs/13.02Kg/1.05CUFT
PLUG
CONNECTOR
CABLE
Standard type P1J: 2.1 * 5.5 * 11mm, tuning fork type, center positive for stock ; Other type available by customer requested
See page 2 ; Other type available by customer requested
NOTE
1. All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.
2. DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3. Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4. Tolerance: includes set up tolerance, line regulation, load regulation.
5. Line regulation is measured from low line to high line at rated load.
6. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives.
7. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
File Name:GS60-SPEC 2011-06-15