English
Language : 

GS40 Datasheet, PDF (1/2 Pages) Mean Well Enterprises Co., Ltd. – 40WAC-DC Single Output Desktop
40W AC-DC Single Output Desktop
GS40 series
Features :
Universal AC input / Full range
No load power consumption<0.3W
Pass energy star (CEC) level for full series
Meet energy star (CEC) level for full series
Meet EISA 2007(Energy Independence and Security Act)
3 pole AC inlet IEC320-C14
Class power ( with earth pin)
Protections: Short circuit / Overload / Over voltage
Fully enclosed plastic case
LED indicator for power on
Approvals: UL / CUL / TUV / BSMI / CCC / CB / FCC / CE
Pass LPS for full series
2 years warranty
SPECIFICATION
TUV
Rheinland
Product Safety
geprUfre
Sicherheit
ORDER NO.
GS40A05-P1J GS40A07-P1J GS40A09-P1J GS40A12-P1J GS40A15-P1J GS40A18-P1J GS40A24-P1J GS40A48-P1J
SAFETY MODEL NO.
GS40A05
GS40A07
GS40A09
GS40A12
GS40A15
GS40A18
GS40A24
GS40A48
DC VOLTAGE
RATED CURRENT
Note.2 5V
5A
7.5V
5.34A
9V
4.45A
12V
3.34A
15V
2.67A
18V
2.22A
24V
1.67A
48V
0.84A
CURRENT RANGE
0 ~ 5A
0 ~ 5.34A
0 ~ 4.45A
0 ~ 3.34A
0 ~ 2.67A
0 ~ 2.22A
0 ~ 1.67A
0 ~ 0.84A
OUTPUT
RATED POWER (max.)
25W
RIPPLE & NOISE (max.) Note.3 100mVp-p
VOLTAGE TOLERANCE Note.4 5.0%
LINE REGULATION Note.5 1.0%
LOAD REGULATION
5.0%
40W
100mVp-p
5.0%
1.0%
5.0%
40W
100mVp-p
5.0%
1.0%
5.0%
40W
100mVp-p
3.0%
1.0%
3.0%
40W
100mVp-p
3.0%
1.0%
3.0%
40W
150mVp-p
3.0%
1.0%
3.0%
40W
180mVp-p
2.5%
1.0%
2.5%
40W
240mVp-p
2.5%
1.0%
2.5%
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
Note.7 600ms, 30ms / 230VAC 600ms, 30ms / 115VAC at full load
50ms / 230VAC 15ms / 115VAC at full load
90 ~ 264VAC 135 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
INPUT
EFFICIENCY (Typ.)
AC CURRENT
80.5%
85.5%
85%
89%
89.5%
90%
91%
92%
1A / 115VAC 0.5A / 230VAC
INRUSH CURRENT (max.) 65A / 230VAC
LEAKAGE CURRENT(max.) 0.75mA / 240VAC
OVERLOAD
PROTECTION
OVER VOLTAGE
105 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
5.25 ~ 6.75V 7.88 ~ 10.13V 9.45 ~ 12.15V 12.6 ~ 16.2V 15.75 ~ 20.25V 18.9 ~ 24.3V
Protection type : Shut down o/p voltage, re-power on to recover
25.2 ~ 32.4V
50.4 ~ 64.8V
WORKING TEMP.
0 ~ +60 (Refer to output load derating curve)
WORKING HUMIDITY
20% ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -20 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03% / (0~50 )
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL60950-1, TUV EN60950-1, BSMI CNS14336, CCC GB4943 approved
SAFETY &
EMC
(Note. 6)
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 class B, FCC PART 15 / CISPR22 class B, CNS13438 class B, GB9254 class B
Compliance to EN61000-3-2,3, GB17625.1
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
OTHERS
CONNECTOR
MTBF
DIMENSION
PACKING
PLUG
CABLE
711Khrs min. MIL-HDBK-217F(25 )
125*50*31.5mm (L*W*H)
0.31Kg; 40pcs/13.4Kg/0.91CUFT
Standard type P1J: 2.1 * 5.5 * 11mm, tuning fork type, center positive for stock ; Other type available by customer requested
See page 2 ; Other type available by customer requested
NOTE
1. All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.
2. DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3. Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4. Tolerance: includes set up tolerance, line regulation, load regulation.
5. Line regulation is measured from low line to high line at rated load.
6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
7. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
File Name:GS40-SPEC 2008-10-22