SPECIFICATION
2 years warranty
ORDER NO.
GS25U05-P1J GS25U07-P1J GS25U09-P1J GS25U12-P1J GS25U15-P1J GS25U18-P1J GS25U24-P1J GS25U28-P1J GS25U48-P1J
SAFETY MODEL NO.
GS25U05 GS25U07 GS25U09 GS25U12 GS25U15 GS25U18 GS25U24 GS25U28 GS25U48
DC VOLTAGE
RATED CURRENT
Note.2 5V
4.0A
7.5V
2.93A
9V
2.77A
12V
2.08A
15V
1.66A
18V
1.38A
24V
1.04A
28V
0.89A
48V
0.52A
CURRENT RANGE
0 ~ 4.0A 0 ~ 2.93A 0 ~ 2.77A 0 ~ 2.08A 0 ~ 1.66A 0 ~ 1.38A 0 ~ 1.04A 0 ~ 0.89A 0 ~ 0.52A
RATED POWER (max.)
20W
OUTPUT
RIPPLE & NOISE (max.) Note.3 50mVp-p
22W
80mVp-p
25W
80mVp-p
25W
80mVp-p
25W
25W
25W
25W
25W
100mVp-p 150mVp-p 180mVp-p 240mVp-p 240mVp-p
VOLTAGE TOLERANCE Note.4 5.0%
5.0%
5.0%
3.0%
3.0%
3.0%
2.0%
2.0%
2.0%
LINE REGULATION Note.5 1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
LOAD REGULATION Note.6 5.0%
5.0%
5.0%
3.0%
3.0%
3.0%
2.0%
2.0%
2.0%
SETUP, RISE, HOLD UP TIME 500ms, 20ms, 50ms/230VAC 500ms, 20ms, 15ms/115VAC at full load
VOLTAGE RANGE
90 ~ 264VAC 135 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
INPUT
EFFICIENCY (Typ.)
AC CURRENT
78.5%
81.5%
82.5%
84.5%
84.5%
84.5%
85.5%
85.5%
87%
0.7A / 100VAC
INRUSH CURRENT (max.) 25A / 115VAC
LEAKAGE CURRENT(max.) 0.25mA / 240VAC
OVERLOAD
PROTECTION
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY &
EMC
(Note. 7)
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC EMISSION
MTBF
OTHERS DIMENSION
PACKING
PLUG
CONNECTOR CABLE
110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
105 ~ 135% rated output voltage
Protection type : Clamp by zener diode
0 ~ +50 (Refer to "Derating Curve")
20% ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH
0.03% / (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, CSA C22.2, BSMI, CNS14336 approved
I/P-O/P:4242VDC
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
Compliance to FCC PART 15 / CISPR22 class B, CNS13438 class B
500Khrs min. MIL-HDBK-217F(25 )
79*54*33mm (L*W*H)
210g ; 60pcs / 13.5kg / CARTON
See page2
See page2
NOTE
1.All parameters are specified at 115VAC input, rated load, 25 70% RH ambient.
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.Tolerance: includes set up tolerance, line regulation, load regulation.
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 20% to 100% rated load
7.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives.
File Name:GS25U-SPEC 2012-02-29