English
Language : 

GS25B Datasheet, PDF (1/2 Pages) Mean Well Enterprises Co., Ltd. – 20~25WAC-DC Single Output Desktop
20~25W AC-DC Single Output Desktop
GS25B series
Features :
Universal AC input / Full range
No load power consumption<0.5W
Pass energy star(CEC) level regulation
Meet EISA 2007 (Energy Independence and Security Act)
2 pole AC Inlet IEC320-C8
Class power (without earth pin)
Full output 5~48V safety approval
Protections: Short circuit / Overload / Over voltage
Fully enclosed plastic case
LED indicator for power on
Approvals: UL / CUL / TUV / BSMI / CB / FCC / CE
Pass LPS for 9~48V output
2 years warranty
SPECIFICATION
TUV
Rheinland
Product Safety
geprUfre
Sicherheit
ORDER NO.
GS25B05-P1J GS25B07-P1J GS25B09-P1J GS25B12-P1J GS25B15-P1J GS25B18-P1J GS25B24-P1J GS25B28-P1J GS25B48-P1J
SAFETY MODEL NO.
GS25B05 GS25B07 GS25B09 GS25B12 GS25B15 GS25B18 GS25B24 GS25B28 GS25B48
DC VOLTAGE
RATED CURRENT
Note.2 5V
4.0A
7.5V
2.93A
9V
2.77A
12V
2.08A
15V
1.66A
18V
1.38A
24V
1.04A
28V
0.89A
48V
0.52A
OUTPUT
CURRENT RANGE
0 ~ 4.0A 0 ~ 2.93A 0 ~ 2.77A 0 ~ 2.08A 0 ~ 1.66A 0 ~ 1.38A
RATED POWER (max.)
20W
22W
25W
25W
25W
25W
RIPPLE & NOISE (max.) Note.3 50mVp-p 80mVp-p 80mVp-p 80mVp-p 100mVp-p 150mVp-p
VOLTAGE TOLERANCE Note.4 5.0%
5.0%
5.0%
3.0%
3.0%
3.0%
LINE REGULATION Note.5 1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
LOAD REGULATION Note.6 5.0%
5.0%
5.0%
3.0%
3.0%
3.0%
SETUP, RISE, HOLD UP TIME 500ms, 20ms, 50ms/230VAC 500ms, 20ms, 15ms/115VAC at full load
VOLTAGE RANGE
90 ~ 264VAC 135 ~ 370VDC
0 ~ 1.04A
25W
180mVp-p
2.0%
1.0%
2.0%
0 ~ 0.89A
25W
240mVp-p
2.0%
1.0%
2.0%
0 ~ 0.52A
25W
240mVp-p
2.0%
1.0%
2.0%
FREQUENCY RANGE
47 ~ 63Hz
INPUT
EFFICIENCY (Typ.)
AC CURRENT
74%
78%
79%
81%
82%
82%
83%
83%
84%
0.7A/100VAC
INRUSH CURRENT (max.) 45A/230VAC
LEAKAGE CURRENT(max.) 0.25mA / 240VAC
OVERLOAD
PROTECTION
OVER VOLTAGE
110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
105 ~ 135% rated output voltage
Protection type : Clamp by zener diode
WORKING TEMP.
0 ~ +50 (Refer to output load derating curve)
WORKING HUMIDITY
20% ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -20 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03% / (0 ~ 50 )
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL60950-1, CSA C22.2, TUV EN60950-1, BSMI CNS14336 approved
SAFETY &
EMC
(Note. 7)
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
I/P-O/P:4242VDC
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 class B, FCC PART 15 / CISPR22 class B, CNS13438 class B
Compliance to EN61000-3-2,3
EMS IMMUNITY
MTBF
OTHERS DIMENSION
PACKING
PLUG
CONNECTOR
CABLE
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
500Khrs min. MIL-HDBK-217F(25 )
79*54*33mm (L*W*H)
210g ; 60pcs / 13.5Kg / CARTON
Standard type P1J: 2.1 * 5.5 * 11mm, turning fork type, centre positive for stock ; Other type available by customer requested
Standard type UL1185 6ft (4FT only for 5V output) for stock ; Other type available by customer requested
NOTE
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.Tolerance: includes set up tolerance, line regulation, load regulation.
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 20% to 100% rated load
7.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:GS25B-SPEC 2008-05-08