English
Language : 

GS220A12-R7B Datasheet, PDF (1/2 Pages) Mean Well Enterprises Co., Ltd. – 220WAC-DC Single Output Desktop
220W AC-DC Single Output Desktop
GS220 series
Features :
Universal AC input / Full range
3 pole AC inlet IEC320-C14
Built-in active PFC function, PF>0.91
Protections: Short circuit / Overload / Over voltage / Over temperature
Fully enclosed plastic case
Approvals: UL / CUL / TUV / BSMI / CCC / CB / FCC / CE
Class power ( with earth pin)
LED indicator for power on
No load power consumption<0.5W
ENERGY STAR level compliant
Meet EISA 2007(Energy Independence and Security Act)
2 years warranty
SPECIFICATION
TUV
Rheinland
Product Safety
geprUfre
Sicherheit
ORDER NO.
GS220A12-R7B
GS220A15-R7B
GS220A20-R7B
GS220A24-R7B
GS220A48-R7B
OUTPUT
INPUT
SAFETY MODEL NO.
GS220A12
GS220A15
GS220A20
DC VOLTAGE
Note.2 12V
15V
20V
RATED CURRENT
15A
13.4A
11A
CURRENT RANGE
0 ~ 15A
0 ~ 13.4A
0 ~ 11A
RATED POWER (max.)
180W
201W
220W
RIPPLE & NOISE (max.) Note.3 80mVp-p
100mVp-p
150mVp-p
VOLTAGE TOLERANCE Note.4 5.0%
5.0%
4.0%
LINE REGULATION Note.5 1.0%
1.0%
1.0%
LOAD REGULATION
5.0%
5.0%
4.0%
SETUP, RISE TIME Note.7 2000ms, 20ms / 230VAC 2000ms, 20ms / 115VAC at full load
HOLD UP TIME (Typ.)
20ms / 230VAC 20ms / 115VAC at full load
VOLTAGE RANGE
Note.8 90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.91 / 230VAC PF>0.98 / 115VAC at full load
EFFICIENCY (Typ.)
90%
90%
92%
AC CURRENT
4A / 115VAC 2A / 230VAC
INRUSH CURRENT (max.) 120A / 230VAC
LEAKAGE CURRENT(max.) 1.5mA / 240VAC
GS220A24
24V
9.2A
0 ~ 9.2A
221W
180mVp-p
3.0%
1.0%
3.0%
93.5%
GS220A48
48V
4.6A
0 ~ 4.6A
221W
240mVp-p
2.0%
1.0%
2.0%
94.5%
OVERLOAD
PROTECTION OVER VOLTAGE
105 ~ 135% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
105 ~ 135% rated output voltage
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE
95 5 (TSW1) detect on heatsink of power transistor
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
WORKING TEMP.
-10 ~ +60 (Refer to output load derating curve)
WORKING HUMIDITY
20% ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -20 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03% / (0~50 )
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL60950-1, TUV EN60950-1, BSMI CNS14336, CCC GB4943 approved
SAFETY &
EMC
(Note. 6)
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
I/P-O/P: 3KVAC
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 class B, FCC PART 15 class B / CISPR22 class B, CNS13438 class B, GB9254 class B
Compliance to EN61000-3-2,3, GB17625.1
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
OTHERS
CONNECTOR
MTBF
DIMENSION
PACKING
PLUG
CABLE
191.3Khrs min. MIL-HDBK-217F(25 )
210*85*46mm (L*W*H)
1.1Kg; 12pcs/14.2Kg/0.73CUFT
See page 2 ; Other type available by customer requested
See page 2 ; Other type available by customer requested
NOTE
1. All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.
2. DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3. Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4. Tolerance: includes set up tolerance, line regulation, load regulation.
5. Line regulation is measured from low line to high line at rated load.
6. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives.
7. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
8. Derating may be needed under low input voltage. Please check the derating curve for more details.
File Name:GS220-SPEC 2009-11-09