English
Language : 

GS18U_11 Datasheet, PDF (1/2 Pages) Mean Well Enterprises Co., Ltd. – 15~18WAC-DC Single Output Wall-mounted type
15~18W AC-DC Single Output Wall-mounted type
GS18U series
Features :
Universal AC input / Full range
No load power consumption<0.3W
ErP step2 compliant
Meet EISA 2007 (Energy Independence and Security Act)
2 pole USA plug
Class power (without earth pin)
Protections: Short circuit / Overload / Over voltage
Fully enclosed plastic case
LED indicator for power on
Approvals: UL / CUL / BSMI / CB / FCC
Pass LPS
2 years warranty
SPECIFICATION
ORDER NO.
GS18U05-P1J GS18U07-P1J GS18U09-P1J GS18U12-P1J GS18U15-P1J GS18U18-P1J GS18U24-P1J GS18U28-P1J GS18U48-P1J
SAFETY MODEL NO.
GS18U05 GS18U07 GS18U09 GS18U12 GS18U15 GS18U18 GS18U24 GS18U28 GS18U48
DC VOLTAGE
Note.2 5V
7.5V
9V
12V
15V
18V
24V
28V
48V
RATED CURRENT
3.0A
2.0A
2.0A
1.50A
1.20A
1.0A
0.75A
0.64A
0.375A
CURRENT RANGE
0 ~ 3.0A 0 ~ 2.0A 0 ~2.0A
0 ~ 1.50A 0 ~ 1.20A 0 ~ 1.0A 0 ~ 0.75A 0 ~ 0.64A 0 ~ 0.375A
RATED POWER (max.)
15W
15W
18W
18W
18W
18W
18W
18W
18W
OUTPUT RIPPLE & NOISE (max.) Note.3 50mVp-p 80mVp-p 80mVp-p 80mVp-p 100mVp-p 150mVp-p 180mVp-p 240mVp-p 240mVp-p
VOLTAGE TOLERANCE Note.4 5.0%
5.0%
5.0%
3.0%
3.0%
3.0%
2.0%
2.0%
2.0%
LINE REGULATION Note.5 1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
LOAD REGULATION Note.6 5.0%
5.0%
5.0%
3.0%
3.0%
3.0%
2.0%
2.0%
2.0%
SETUP, RISE, HOLD UP TIME 500ms, 20ms, 50ms/230VAC 500ms, 20ms, 15ms/115VAC at full load
VOLTAGE RANGE
90 ~ 264VAC 135 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
INPUT
EFFICIENCY (Typ.)
AC CURRENT
79.5%
82%
83%
85%
85%
85%
86%
86.5%
87%
0.5A / 100VAC
INRUSH CURRENT (max.) 25A / 115VAC
LEAKAGE CURRENT(max.) 0.25mA / 240VAC
OVERLOAD
PROTECTION
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY &
EMC
(Note. 7)
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC EMISSION
110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
105 ~ 150% rated output voltage
Protection type : Clamp by zener diode, output short
0 ~ +50 (Refer to "Derating Curve")
20% ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH
0.03% / (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, CSA C22.2, BSMI,CNS14336 approved
I/P-O/P:4242VDC
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
Compliance to FCC PART 15 / CISPR22 class B, CNS13438 class B
OTHERS
CONNECTOR
MTBF
DIMENSION
PACKING
PLUG
CABLE
500Khrs min. MIL-HDBK-217F(25 )
79*54*33mm (L*W*H)
210g ; 60pcs / 13.5kg / CARTON
See page2
See page2
NOTE
1.All parameters are specified at 115VAC input, rated load, 25 70% RH ambient.
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.Tolerance: includes set up tolerance, line regulation, load regulation.
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 20% to 100% rated load
7.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives.
File Name:GS18U-SPEC 2011-06-14