English
Language : 

GS18E Datasheet, PDF (1/2 Pages) Mean Well Enterprises Co., Ltd. – 10~18WAC-DC Single Output Wall-mounted type
10~18W AC-DC Single Output Wall-mounted type
GS18E series
Features :
Universal AC input / Full range
No load power consumption<0.5W
Pass energy star(CEC) level for 5~48V output
Meet EISA 2007 (Energy Independence and Security Act) for 5 ~ 48V
2 pole EURO plug
Class power (without earth pin)
Full output 3~48V safety approval
Protections: Short circuit / Over load / Over voltage
Fully enclosed plastic case
LED indicator for power on
Approvals: TUV / CB / CE
Pass LPS for 9~48V output
SPECIFICATION
2 years warranty
TUV
Rheinland
Product Safety
geprUfre
Sicherheit
ORDER NO.
GS18E03-P1J GS18E05-P1J GS18E07-P1J GS18E09-P1J GS18E12-P1J GS18E15-P1J GS18E18-P1J GS18E24-P1J GS18E28-P1J GS18E48-P1J
SAFETY MODEL NO.
GS18E03 GS18E05 GS18E07 GS18E09 GS18E12 GS18E15 GS18E18 GS18E24 GS18E28 GS18E48
DC VOLTAGE
Note.2 3.3V
5V
7.5V
9V
12V
15V
18V
24V
28V
48V
RATED CURRENT
3.0A
3.0A
2.0A
2.0A
1.50A
1.20A
1.0A
0.75A
0.64A
0.375A
CURRENT RANGE
0 ~ 3.0A 0 ~ 3.0A 0 ~ 2.0A 0 ~2.0A 0 ~ 1.50A 0 ~ 1.20A 0 ~ 1.0A 0 ~ 0.75A 0 ~ 0.64A 0 ~ 0.375A
OUTPUT
RATED POWER (max.)
10W
15W
15W
18W
18W
18W
RIPPLE & NOISE (max.) Note.3 50mVp-p 50mVp-p 80mVp-p 80mVp-p 80mVp-p 100mVp-p
VOLTAGE TOLERANCE Note.4 5.0%
5.0%
5.0%
5.0%
3.0%
3.0%
LINE REGULATION Note.5 1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
LOAD REGULATION Note.6 5.0%
5.0%
5.0%
5.0%
3.0%
3.0%
SETUP, RISE, HOLD UP TIME 500ms, 20ms, 50ms/230VAC 500ms, 20ms, 15ms/115VAC at full load
VOLTAGE RANGE
90 ~ 264VAC 135 ~ 370VDC
18W
150mVp-p
3.0%
1.0%
3.0%
18W
180mVp-p
2.0%
1.0%
2.0%
18W
240mVp-p
2.0%
1.0%
2.0%
18W
240mVp-p
2.0%
1.0%
2.0%
FREQUENCY RANGE
47 ~ 63Hz
INPUT
EFFICIENCY (Typ.)
AC CURRENT
68%
73%
79%
79%
81%
81%
82%
84%
84%
85%
0.5A / 100VAC
INRUSH CURRENT (max.) 45A / 230VAC
LEAKAGE CURRENT(max.) 0.25mA / 240VAC
OVERLOAD
PROTECTION
OVER VOLTAGE
110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
105 ~ 135% rated output voltage
Protection type : Clamp by zener diode, output short
WORKING TEMP.
0 ~ +50 (Refer to output load derating curve)
WORKING HUMIDITY
20% ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -20 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03% / (0 ~ 50 )
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS
TUV EN60950-1 approved
SAFETY &
EMC
(Note. 7)
WITHSTAND VOLTAGE
I/P-O/P:4242VDC
ISOLATION RESISTANCE I/P-O/P:100M Ohms / 500VDC / 25
EMI CONDUCTION & RADIATION Compliance to EN55022 class B
HARMONIC CURRENT
Compliance to EN61000-3-2,3
/ 70% RH
EMS IMMUNITY
MTBF
OTHERS DIMENSION
PACKING
PLUG
CONNECTOR
CABLE
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
500Khrs min. MIL-HDBK-217F(25 )
79*54*33mm (L*W*H)
210g ; 60pcs / 13.5kg / CARTON
Standard type P1J: 2.1 * 5.5 * 11mm, tuning fork type, centre positive for stock ; Other type available by customer requested
Standard type UL1185 6ft (4FT for 3.3 ~ 5V output) for stock ; Other type available by customer requested
NOTE
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.Tolerance: includes set up tolerance, line regulation, load regulation.
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 20% to 100% rated load
7.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:GS18E-SPEC 2008-05-08