English
Language : 

GS18B_11 Datasheet, PDF (1/2 Pages) Mean Well Enterprises Co., Ltd. – 15~18WAC-DC Single Output Desktop
15~18W AC-DC Single Output Desktop
GS18B series
Features :
Universal AC input / Full range
No load power consumption<0.3W
ErP step2 compliant
Meet EISA 2007 (Energy Independence and Security Act)
2 pole AC inlet IEC320-C8
Class power (without earth pin)
Protections: Short circuit / Overload / Over voltage
Fully enclosed plastic case
LED indicator for power on
Approvals: UL / CUL / TUV / BSMI / CCC / CB / FCC / CE
Pass LPS
2 years warranty
SPECIFICATION
ORDER NO.
GS18B05-P1J GS18B07-P1J GS18B09-P1J GS18B12-P1J GS18B15-P1J GS18B18-P1J GS18B24-P1J GS18B28-P1J GS18B48-P1J
SAFETY MODEL NO.
GS18B05 GS18B07 GS18B09 GS18B12 GS18B15 GS18B18 GS18B24 GS18B28 GS18B48
DC VOLTAGE
Note.2 5V
7.5V
9V
12V
15V
18V
24V
28V
48V
RATED CURRENT
3.0A
2.0A
2.0A
1.50A
1.20A
1.0A
0.75A
0.64A
0.375A
CURRENT RANGE
0 ~ 3.0A 0 ~ 2.0A 0 ~2.0A
0 ~ 1.50A 0 ~ 1.20A 0 ~ 1.0A 0 ~ 0.75A 0 ~ 0.64A 0 ~ 0.375A
RATED POWER (max.)
15W
OUTPUT RIPPLE & NOISE (max.) Note.3 50mVp-p
15W
80mVp-p
18W
80mVp-p
18W
80mVp-p
18W
18W
18W
18W
18W
100mVp-p 150mVp-p 180mVp-p 240mVp-p 240mVp-p
VOLTAGE TOLERANCE Note.4 5.0%
5.0%
5.0%
3.0%
3.0%
3.0%
2.0%
2.0%
2.0%
LINE REGULATION Note.5 1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
LOAD REGULATION Note.6 5.0%
5.0%
5.0%
3.0%
3.0%
3.0%
2.0%
2.0%
2.0%
SETUP, RISE, HOLD UP TIME 500ms, 20ms, 50ms/230VAC 500ms, 20ms, 15ms/115VAC at full load
VOLTAGE RANGE
90 ~ 264VAC 135 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
INPUT
EFFICIENCY (Typ.)
AC CURRENT
79.5%
82%
83%
85%
85%
85%
86%
86.5%
87%
0.5A / 100VAC
INRUSH CURRENT (max.) 45A / 230VAC
LEAKAGE CURRENT(max.) 0.25mA / 240VAC
OVERLOAD
PROTECTION
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY &
EMC
(Note. 7)
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC EMISSION
EMC IMMUNITY
MTBF
OTHERS DIMENSION
PACKING
PLUG
CONNECTOR CABLE
110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
105 ~ 135% rated output voltage
Protection type : Clamp by zener diode, output short
0 ~ +50 (Refer to "Derating Curve")
20% ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH
0.03% / (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, CSA C22.2, TUV EN60950-1, BSMI CNS14336, CCC GB4943 approved
I/P-O/P:4242VDC
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022, EN61000-3-2,3, FCC PART 15 / CISPR22 class B, CNS13438 class B, GB9254
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
500Khrs min. MIL-HDBK-217F(25 )
79*54*33mm (L*W*H)
210g ; 60pcs / 13.5kg / CARTON
See page2
See page2
NOTE
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.Tolerance: includes set up tolerance, line regulation, load regulation.
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 20% to 100% rated load
7.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives.
File Name:GS18B-SPEC 2011-06-14