English
Language : 

GS18B Datasheet, PDF (1/2 Pages) Mean Well Enterprises Co., Ltd. – 10~18WAC-DC Single Output Desktop
10~18W AC-DC Single Output Desktop
GS18B series
Features :
Universal AC input / Full range
No load power consumption<0.5W
Pass energy star(CEC) level for 5~48V output
Meet EISA 2007 (Energy Independence and Security Act) for 5 ~ 48V
2 pole AC inlet IEC320-C8
Class power (without earth pin)
Full output 3~48V safety approval
Protections: Short circuit / Overload / Over voltage
Fully enclosed plastic case
LED indicator for power on
Approvals: UL / CUL / TUV / BSMI / CB / FCC / CE
Pass LPS for 9~48V output
2 years warranty
SPECIFICATION
TUV
Rheinland
Product Safety
geprUfre
Sicherheit
ORDER NO.
GS18B03-P1J GS18B05-P1J GS18B07-P1J GS18B09-P1J GS18B12-P1J GS18B15-P1J GS18B18-P1J GS18B24-P1J GS18B28-P1J GS18B48-P1J
OUTPUT
INPUT
SAFETY MODEL NO.
GS18B03 GS18B05 GS18B07 GS18B09 GS18B12 GS18B15
DC VOLTAGE
Note.2 3.3V
5V
7.5V
9V
12V
15V
RATED CURRENT
3.0A
3.0A
2.0A
2.0A
1.50A
1.20A
CURRENT RANGE
0 ~ 3.0A 0 ~ 3.0A 0 ~ 2.0A 0 ~2.0A 0 ~ 1.50A 0 ~ 1.20A
RATED POWER (max.)
10W
15W
15W
18W
18W
18W
RIPPLE & NOISE (max.) Note.3 50mVp-p 50mVp-p 80mVp-p 80mVp-p 80mVp-p 100mVp-p
VOLTAGE TOLERANCE Note.4 5.0%
5.0%
5.0%
5.0%
3.0%
3.0%
LINE REGULATION Note.5 1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
LOAD REGULATION Note.6 5.0%
5.0%
5.0%
5.0%
3.0%
3.0%
SETUP, RISE, HOLD UP TIME 500ms, 20ms, 50ms/230VAC 500ms, 20ms, 15ms/115VAC at full load
VOLTAGE RANGE
90 ~ 264VAC 135 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.)
68%
73%
79%
79%
81%
81%
AC CURRENT
0.5A / 100VAC
INRUSH CURRENT (max.) 45A / 230VAC
LEAKAGE CURRENT(max.) 0.25mA / 240VAC
GS18B18
18V
1.0A
0 ~ 1.0A
18W
150mVp-p
3.0%
1.0%
3.0%
82%
GS18B24
24V
0.75A
0 ~ 0.75A
18W
180mVp-p
2.0%
1.0%
2.0%
84%
GS18B28
28V
0.64A
0 ~ 0.64A
18W
240mVp-p
2.0%
1.0%
2.0%
84%
GS18B48
48V
0.375A
0 ~ 0.375A
18W
240mVp-p
2.0%
1.0%
2.0%
85%
OVERLOAD
PROTECTION
OVER VOLTAGE
110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
105 ~ 135% rated output voltage
Protection type : Clamp by zener diode, output short
WORKING TEMP.
0 ~ +50 (Refer to output load derating curve)
WORKING HUMIDITY
20% ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -20 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03% / (0 ~ 50 )
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL60950-1, CSA C22.2, TUV EN60950-1, BSMI CNS14336 approved
SAFETY &
EMC
(Note. 7)
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
I/P-O/P:4242VDC
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 class B, FCC PART 15 / CISPR22 class B, CNS13438 class B
Compliance to EN61000-3-2,3
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
MTBF
500Khrs min. MIL-HDBK-217F(25 )
OTHERS DIMENSION
79*54*33mm (L*W*H)
PACKING
210g ; 60pcs / 13.5kg / CARTON
PLUG
CONNECTOR
CABLE
Standard type P1J: 2.1 * 5.5 * 11mm, tuning fork type, center positive for stock ; Other type available by customer requested
Standard type UL1185 6ft (4FT for 3.3 ~ 5V output) for stock ; Other type available by customer requested
NOTE
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.Tolerance: includes set up tolerance, line regulation, load regulation.
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 20% to 100% rated load
7.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:GS18B-SPEC 2008-05-08