English
Language : 

GS160_1011 Datasheet, PDF (1/2 Pages) Mean Well Enterprises Co., Ltd. – 160WAC-DC Single Output Desktop
160W AC-DC Single Output Desktop
GS160 series
Features :
Universal AC input / Full range
3 pole AC inlet IEC320-C14
Built-in active PFC function, PF>0.95
Protections: Short circuit / Overload / Over voltage / Over temperature
Fully enclosed plastic case
Approvals: UL / CUL / TUV / BSMI / CCC / CB / FCC / CE
Class power ( with earth pin)
LED indicator for power on
No load power consumption<0.5W
Meet EISA 2007(Energy Independence and Security Act)
2 years warranty
SPECIFICATION
TUV
Rheinland
Product Safety
geprUfre
Sicherheit
ORDER NO.
GS160A12-R7B
GS160A15-R7B
GS160A20-R7B
GS160A24-R7B
GS160A48-R7B
SAFETY MODEL NO.
DC VOLTAGE
GS160A12
12V
GS160A15
15V
GS160A20
20V
GS160A24
24V
GS160A48
48V
RATED CURRENT
11.5A
9.6A
8A
6.67A
3.34A
CURRENT RANGE
0 ~ 11.5A
0 ~ 9.6A
0 ~ 8A
0 ~ 6.67A
0 ~ 3.34A
RATED POWER (max.)
138W
144W
160W
160W
160W
OUTPUT
RIPPLE & NOISE (max.) Note.2 80mVp-p
VOLTAGE TOLERANCE Note.3 5.0%
LINE REGULATION Note.4 1.0%
LOAD REGULATION
5.0%
100mVp-p
5.0%
1.0%
5.0%
150mVp-p
4.0%
1.0%
4.0%
180mVp-p
3.0%
1.0%
3.0%
240mVp-p
3.0%
1.0%
3.0%
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
Note.6 2000ms, 20ms / 230VAC 2500ms, 20ms / 115VAC at full load
20ms / 230VAC 20ms / 115VAC at full load
Note.7 85 ~ 264VAC 120 ~ 370VDC
47 ~ 63Hz
INPUT
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
PF>0.95 / 230VAC
89%
PF>0.98 / 115VAC at full load
90%
92%
92.5%
94%
AC CURRENT
INRUSH CURRENT (max.)
LEAKAGE CURRENT(max.)
1.85A / 115VAC
120A / 230VAC
0.75mA / 240VAC
1A / 230VAC
OVERLOAD
PROTECTION OVER VOLTAGE
105 ~ 135% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
105 ~ 135% rated output voltage
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE
90 10 (RTH2) detect on inside ambient temperature
Protection type : Shut down o/p voltage, re-power on to recover
WORKING TEMP.
-30 ~ +70 (Refer to output load derating curve)
WORKING HUMIDITY
20% ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -20 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03% / (0~50 )
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL60950-1, TUV EN60950-1, BSMI CNS14336, CCC GB4943 approved
SAFETY &
EMC
(Note. 5)
WITHSTAND VOLTAGE
I/P-O/P: 3KVAC
ISOLATION RESISTANCE I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
EMI CONDUCTION & RADIATION Compliance to EN55022(CISPR22) ,EN61204-3 class B, CNS13438 class B, GB9254-1 class B
HARMONIC CURRENT
Compliance to EN61000-3-2,3, GB17625.1
EMS IMMUNITY
OTHERS
CONNECTOR
MTBF
DIMENSION
PACKING
PLUG
CABLE
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
290.3Khrs min. MIL-HDBK-217F(25 )
175*72*35mm (L*W*H)
0.66Kg; 20pcs/ 14.2Kg/ 0.85CUFT
See page 2 ; Other type available by customer requested
See page 2 ; Other type available by customer requested
NOTE
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.
2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
3.Tolerance: includes set up tolerance, line regulation, load regulation.
4.Line regulation is measured from low line to high line at rated load.
5.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. Derating may be needed under low input voltage. Please check the derating curve for more details.
File Name:GS160-SPEC 2010-11-12