English
Language : 

GS15B Datasheet, PDF (1/2 Pages) Mean Well Enterprises Co., Ltd. – 7.2~15WAC-DC Single Output Desktop
7.2~15W AC-DC Single Output Desktop
GS15B series
SPECIFICATION
Features :
Universal AC input / Full range
No load power consumption <0.5W
Meet energy star level IV(CEC) for 5 ~ 48V
Meet EISA 2007 (Energy Independence and Security Act) for 5 ~ 48V
2 pole AC inlet IEC320-C8
Class power ( without earth pin)
Full output 3~48V safety approval
Protections: Short circuit / Overload / Over voltage
Pass LPS
Fully enclosed plastic case
Approvals: UL / CUL / TUV / CB / FCC / CE
2 years warranty
TUV
Rheinland
Product Safety
geprUfre
Sicherheit
ORDER NO.
GS15B-0P1J GS15B-1P1J GS15B-11P1J GS15B-2P1J GS15B-3P1J GS15B-4P1J GS15B-5P1J GS15B-6P1J GS15B-8P1J
SAFETY MODEL NO.
GPSU15B-0 GPSU15B-1 GPSU15B-1-1 GPSU15B-2 GPSU15B-3 GPSU15B-4 GPSU15B-5 GPSU15B-6 GPSU15B-8
DC VOLTAGE
Note.2 3.3V
5V
7.5V
9V
12V
15V
18V
24V
48V
RATED CURRENT
2.18A
2.40A
1.60A
1.66A
1.25A
1.00A
0.83A
0.62A
0.31A
CURRENT RANGE
0 ~ 2.18A 0 ~ 2.40A 0 ~ 1.60A 0 ~1.66A 0 ~ 1.25A 0 ~ 1.00A 0 ~ 0.83A 0 ~ 0.62A 0 ~ 0.31A
RATED POWER
7.2W
12W
12W
15W
15W
15W
15W
15W
15W
OUTPUT
RIPPLE & NOISE (max.) Note.3 50mVp-p
VOLTAGE ADJ. RANGE
3 ~ 5V
Fixed
50mVp-p
5 ~ 6V
80mVp-p
6 ~ 8V
80mVp-p
8 ~ 11V
80mVp-p
11 ~ 13V
100mVp-p 120mVp-p 150mVp-p 240mVp-p
13 ~ 16V 16 ~ 21V 21 ~ 27V 33 ~ 48V
VOLTAGE TOLERANCE Note.4 6.0%
5.0%
5.0%
5.0%
3.0%
3.0%
3.0%
2.0%
2.0%
LINE REGULATION Note.5 1.0%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
LOAD REGULATION Note.6 6.0%
5.0%
5.0%
5.0%
3.0%
3.0%
3.0%
2.0%
2.0%
SETUP, RISE, HOLD UP TIME 3000ms, 50ms, 16ms at full load
VOLTAGE RANGE
90 ~ 264VAC 135 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.) Note.7 55%
65%
72%
74%
76%
77%
78%
80%
81%
INPUT
AC CURRENT
0.5A / 100VAC
INRUSH CURRENT (max.) 50A / 230VAC
LEAKAGE CURRENT(max.) 0.25mA / 240VAC
OVERLOAD
PROTECTION
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
115 ~ 250% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
>120% rated output voltage
Protection type : Clamp by zener diode
0 ~ +50 (Refer to output load derating curve)
20% ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH
0.03% / (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY &
EMC
(Note. 8)
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
UL60950-1, CSA22.2, EN60950-1 approved
I/P-O/P:3KVAC
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 class B, FCC part 15 Class B
Compliance to EN61000-3-2,3
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,11, light industry level, criteria A
MTBF
500Khrs min. MIL-HDBK-217F(25 )
OTHERS DIMENSION
PACKING
PLUG
CONNECTOR CABLE
100*58.5*32.8mm (L*W*H)
190g ; 90pcs / 18Kg / CARTON
Standard type P1J: 2.1 * 5.5 * 11mm, tuning fork type center positive for stock ; Other type available by customer requested
Standard type 18Awg UL1185 6ft and 5ft for 3.3V output only for stock ; Other type available by customer requested
NOTE
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.Tolerance: includes set up tolerance, line regulation, load regulation.
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 0% to 100% rated load
7.Efficiency is measured at 230VAC.
8.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:GS15B-SPEC 2008-05-06