English
Language : 

GS15A_11 Datasheet, PDF (1/2 Pages) Mean Well Enterprises Co., Ltd. – 12~15WAC-DC Single Output Desktop
12~15W AC-DC Single Output Desktop
GS15A series
Features :
Universal AC input / Full range
No load power consumption <0.3W
ErP step2 compliant
Meet EISA 2007 (Energy Independence and Security Act)
3 pole AC inlet IEC320-C14
Class power ( with earth pin)
Protections: Short circuit / Overload / Over voltage
Pass LPS
Fully enclosed plastic case
Approvals: UL / CUL / TUV / CB / FCC / CE
2 years warranty
SPECIFICATION
TUV
Rheinland
Product Safety
geprUfre
Sicherheit
ORDER NO.
GS15A-1P1J GS15A-11P1J GS15A-2P1J GS15A-3P1J GS15A-4P1J GS15A-5P1J GS15A-6P1J GS15A-8P1J
OUTPUT
INPUT
SAFETY MODEL NO.
GPSU15A-1 GPSU15A-1-1 GPSU15A-2
DC VOLTAGE
Note.2 5V
7.5V
9V
RATED CURRENT
2.40A
1.60A
1.66A
CURRENT RANGE
0 ~ 2.40A
0 ~ 1.60A
0 ~1.66A
RATED POWER
12W
12W
15W
RIPPLE & NOISE (max.) Note.3 50mVp-p
80mVp-p
80mVp-p
VOLTAGE ADJ. RANGE
5 ~ 6V
Fixed
6 ~ 8V
8 ~ 11V
VOLTAGE TOLERANCE Note.4 5.0%
5.0%
5.0%
LINE REGULATION Note.5 0.5%
0.5%
0.5%
LOAD REGULATION Note.6 5.0%
5.0%
5.0%
SETUP, RISE, HOLD UP TIME 3000ms, 50ms, 16ms at full load
VOLTAGE RANGE
90 ~ 264VAC 135 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.) Note.7 75%
78%
80%
AC CURRENT
0.5A / 100VAC
INRUSH CURRENT (max.) 50A / 230VAC
LEAKAGE CURRENT(max.) 0.25mA / 240VAC
GPSU15A-3
12V
1.25A
0 ~ 1.25A
15W
80mVp-p
11 ~ 13V
3.0%
0.5%
3.0%
80%
GPSU15A-4
15V
1.00A
0 ~ 1.00A
15W
100mVp-p
13 ~ 16V
3.0%
0.5%
3.0%
80%
GPSU15A-5
18V
0.83A
0 ~ 0.83A
15W
120mVp-p
16 ~ 21V
3.0%
0.5%
3.0%
81%
GPSU15A-6
24V
0.62A
0 ~ 0.62A
15W
150mVp-p
21 ~ 27V
2.0%
0.5%
2.0%
83%
GPSU15A-8
48V
0.31A
0 ~ 0.31A
15W
240mVp-p
33 ~ 48V
2.0%
0.5%
2.0%
85%
OVERLOAD
PROTECTION
OVER VOLTAGE
105 ~ 250% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
>120% rated output voltage
Protection type : Clamp by zener diode
WORKING TEMP.
WORKING HUMIDITY
0 ~ +50 (Refer to "Derating Curve")
20% ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -20 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03% / (0 ~ 50 )
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL60950-1, CSA22.2, EN60950-1 approved
SAFETY & WITHSTAND VOLTAGE
EMC
ISOLATION RESISTANCE
(Note. 8) EMC EMISSION
I/P-O/P:3KVAC , I/P-FG:1.5KVAC
I/P-O/P, I/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022, EN61000-3-2,3, FCC part 15 Class B
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,11, light industry level, criteria A
MTBF
500Khrs min. MIL-HDBK-217F(25 )
OTHERS DIMENSION
100*58.5*32.8mm (L*W*H)
PACKING
PLUG
CONNECTOR
CABLE
190g ; 90pcs / 18Kg / CARTON
Standard type P1J: 2.1 * 5.5 * 11mm, tuning fork type center positive for stock ; Other type available by customer requested
Standard type 18Awg UL1185 6ft and 5ft for 3.3V output only for stock ; Other type available by customer requested
NOTE
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.Tolerance: includes set up tolerance, line regulation, load regulation.
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 0% to 100% rated load
7.Efficiency is measured at 230VAC.
8.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:GS15A-SPEC 2011-06-14