English
Language : 

GS120_12 Datasheet, PDF (1/2 Pages) Mean Well Enterprises Co., Ltd. – 120WAC-DC Single Output Desktop
120W AC-DC Single Output Desktop
GS120 series
Features :
Universal AC input / Full range
3 pole AC inlet IEC320-C14
Built-in active PFC function, PF>0.97
Protections: Short circuit / Overload / Over voltage / Over temperature
Fully enclosed plastic case
Approvals: UL / CUL / PSE / TUV / BSMI / CCC / CB / FCC / CE
Class power (with earth pin)
LED indicator for power on
No load power consumption<0.5W
ErP step2 compliant
NRCan compliant
Meet EISA 2007 (Energy Independence and Security Act)
2 years warranty
SPECIFICATION
(except for 48V)
TUV
Rheinland
Product Safety
geprUfre
Sicherheit
ORDER NO.
GS120A12-R7B
GS120A15-R7B
GS120A20-
=R7B,P1M
GS120A24-
=R7B,P1M
GS120A48-
=R7B,P1M
SAFETY MODEL NO.
DC VOLTAGE
GS120A12
12V
GS120A15
15V
GS120A20
20V
GS120A24
24V
GS120A48
48V
RATED CURRENT
8.5A
7A
6A
5A
2.5A
CURRENT RANGE
0 ~ 8.5A
0 ~ 7A
0 ~ 6A
0 ~ 5A
0 ~ 2.5A
RATED POWER (max.)
102W
105W
120W
120W
120W
OUTPUT
RIPPLE & NOISE (max.) Note.2 80mVp-p
VOLTAGE TOLERANCE Note.3 5.0%
LINE REGULATION Note.4 1.0%
LOAD REGULATION
5.0%
120mVp-p
5.0%
1.0%
5.0%
150mVp-p
5.0%
1.0%
4.0%
180mVp-p
3.0%
1.0%
3.0%
240mVp-p
2.0%
1.0%
2.0%
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
Note.6 2000ms, 30ms / 230VAC 2500ms, 30ms / 115VAC at full load
20ms / 230VAC 20ms / 115VAC at full load
Note.7 85 ~ 264VAC 120 ~ 370VDC
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.97 / 230VAC PF>0.99 / 115VAC at full load
INPUT
R7B
EFFICIENCY (Typ.)
P1M
AC CURRENT
INRUSH CURRENT (max.)
LEAKAGE CURRENT(max.)
87.5%
-----
1.4A / 115VAC
70A / 230VAC
0.75mA / 240VAC
89%
-----
0.7A / 230VAC
89%
88.5%
90%
89.5%
91%
90.5%
OVERLOAD
PROTECTION OVER VOLTAGE
105 ~ 160% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
105 ~ 135% rated output voltage
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE
RTH2 100 10
Protection type : Shut down o/p voltage, re-power on to recover
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
EMC
ISOLATION RESISTANCE
(Note. 5) EMC EMISSION
-30 ~ +70 (Refer to "Derating Curve")
20% ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH
0.03% / (0~50 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1, BSMI CNS14336, CCC GB4943, J60950-1(except for 48V) approved
I/P-O/P: 3KVAC
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022(CISPR22) ,EN61204-3 class B, CNS13438 class B, GB9254-1 class B, FCC PART 15, EN61000-3-2,3, GB17625.1
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
OTHERS
CONNECTOR
MTBF
DIMENSION
PACKING
PLUG
CABLE
400.7Khrs min. MIL-HDBK-217F(25 )
167*67*35mm (L*W*H)
0.62Kg; 20pcs/13.4Kg/0.9CUFT
See page 2 ; Other type available by customer requested
See page 2 ; Other type available by customer requested
NOTE
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.
2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
3.Tolerance: includes set up tolerance, line regulation, load regulation.
4.Line regulation is measured from low line to high line at rated load.
5.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. Derating may be needed under low input voltage. Please check the derating curve for more details.
File Name:GS120-SPEC 2012-03-06