English
Language : 

GS06U_11 Datasheet, PDF (1/2 Pages) Mean Well Enterprises Co., Ltd. – 5 ~ 6WAC-DC Single Output Wall-mounted type
5 ~ 6W AC-DC Single Output Wall-mounted type
GS06U series
Features :
Universal AC input / Full range
No load power consumption <0.3W
ErP step2 compliant
Meet EISA 2007 (Energy Independence and Security Act)
2 pole USA plug
Class power (without earth pin)
Protections: Short circuit / Overload / Over voltage
Pass LPS
Fully enclosed plastic case
Approvals: UL / CUL / CB / FCC / CE
2 years warranty
SPECIFICATION
ORDER NO.
GS06U-1P1J GS06U-11P1J GS06U-2P1J GS06U-3P1J GS06U-4P1J GS06U-5P1J GS06U-6P1J GS06U-8P1J
OUTPUT
INPUT
SAFETY MODEL NO.
GPSU06U-1 GPSU06U-1-1 GPSU06U-2
DC VOLTAGE
Note.2 5V
7.5V
9V
RATED CURRENT
1.00A
0.8A
0.66A
CURRENT RANGE
0 ~ 1.00A
0 ~ 0.8A
0 ~ 0.66A
RATED POWER
5W
6W
6W
RIPPLE & NOISE (max.) Note.3 50mVp-p
80mVp-p
80mVp-p
VOLTAGE ADJ. RANGE
5 ~ 6V
Fixed
6 ~ 8V
8 ~ 11V
VOLTAGE TOLERANCE Note.4 5.0%
5.0%
5.0%
LINE REGULATION Note.5 0.5%
0.5%
0.5%
LOAD REGULATION Note.6 5.0%
5.0%
5.0%
SETUP, RISE, HOLD UP TIME 1000ms, 50ms, 12ms at full load
VOLTAGE RANGE
90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.) Note.7 68%
74%
75%
AC CURRENT
0.2A / 100VAC
INRUSH CURRENT (max.) 50A / 230VAC
LEAKAGE CURRENT(max.) 0.25mA / 240VAC
GPSU06U-3
12V
0.5A
0 ~ 0.5A
6W
100mVp-p
11 ~ 13V
3.0%
0.5%
3.0%
77%
GPSU06U-4
15V
0.4A
0 ~ 0.4A
6W
120mVp-p
13 ~ 16V
3.0%
0.5%
3.0%
78%
GPSU06U-5
18V
0.33A
0 ~ 0.33A
6W
150mVp-p
16 ~ 21V
3.0%
0.5%
3.0%
78%
GPSU06U-6
24V
0.25A
0 ~ 0.25A
6W
180mVp-p
21 ~ 27V
2.0%
0.5%
2.0%
82%
GPSU06U-8
48V
0.125A
0 ~ 0.125A
6W
200mVp-p
33 ~ 48V
2.0%
0.5%
2.0%
84%
OVERLOAD
PROTECTION
OVER VOLTAGE
>105% rated output voltage power for 5V ; >110% rated output power for 7.5 ~ 48V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
>120% rated output voltage
Protection type : Clamp by zener diode
WORKING TEMP.
WORKING HUMIDITY
0 ~ +40 (Refer to "Derating Curve")
20% ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -20 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03% / (0 ~ 50 )
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL60950-1, CSA22.2 approved
SAFETY & WITHSTAND VOLTAGE
EMC
ISOLATION RESISTANCE
(Note. 8) EMC EMISSION
I/P-O/P:4242VDC
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022, EN61000-3-2,3, FCC part 15 Class B
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,11, light industry level, criteria A
MTBF
500Khrs min. MIL-HDBK-217F(25 )
OTHERS DIMENSION
32*66*42.5mm (L*W*H)
PACKING
PLUG
CONNECTOR
CABLE
100g ; 110pcs / 12Kg / CARTON
Standard type P1J: 2.1 * 5.5 * 11mm, turning fork type center positive for stock ; Other type available by customer requested
Standard type 20Awg UL1185 6ft for stock ; Other type available by customer requested
NOTE
1.All parameters are specified at 115VAC input, rated load, 25 70% RH ambient.
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.Tolerance: includes set up tolerance, line regulation, load regulation.
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 0% to 100% rated load
7.Efficiency is measured at 115VAC.
8.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives.
File Name:GS06U-SPEC 2011-06-14