English
Language : 

GE24 Datasheet, PDF (1/2 Pages) Mean Well Enterprises Co., Ltd. – 15~24WAC-DC Single Output Interchangeable Wall-mounted type
G E 2 4 15 ~ 24W AC-DC Single Output Interchangeable Wall-mounted type
series
AC INLET PLUG
Features :
Interchangeable AC plugs (plug kit sold seperately)
Universal AC input / Full range
No load power consumption< 0.3W
ErP step2 compliant
Meet EISA 2007 (Energy Independence and Security Act) for 5~48V
Class power (without earth pin)
Protections: Short circuit / Overload / Over voltage
Fully enclosed plastic case
LED indicator for power on
Pass LPS
Approvals: UL / CUL / TUV / CCC / CB / FCC / CE / C-Tick
2 years warranty
TYPE
Australian type
ORDER NO.
AC plug-AU
SPECIFICATION
U.K type
AC plug-UK
European type
AC plug-EU
US type
AC plug-US
Mix four type
AC plug-MIX
POWER SUPPLY MAIN BODY ORDER NO. GE24I 05-P1J GE24I 07-P1J GE24 I09-P1J GE24 I12-P1J GE24 I15-P1J GE24 I18-P1J GE24 I24-P1J GE24 I48-P1J
SAFETY MODEL NO.
FRA024-S05- I FRA024-S07- I FRA024-S09- I FRA024-S12- I FRA024-S15- I FRA024-S18- I FRA024-S24- I FRA024-S48- I
DC VOLTAGE
Note.2 5V
7.5V
9V
12V
15V
18V
24V
48V
RATED CURRENT
3.0A
2.0A
2.22A
2.0A
1.6A
1.33A
1.0A
0.5A
CURRENT RANGE
0 ~ 3.0A
0 ~ 2.0A
0 ~ 2.22A 0 ~ 2.0A
0 ~ 1.6A
0 ~ 1.33A
0 ~ 1.0A
0 ~ 0.5A
RATED POWER (max.)
15W
OUTPUT
RIPPLE & NOISE (max.) Note.3 50mVp-p
15W
75mVp-p
20W
100mVp-p
24W
120mVp-p
24W
150mVp-p
24W
180mVp-p
24W
240mVp-p
24W
300mVp-p
VOLTAGE TOLERANCE Note.4 5.0%
5.0%
5.0%
3.0%
3.0%
3.0%
3.0%
3.0%
LINE REGULATION Note.5 1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
LOAD REGULATION Note.6 5.0%
5.0%
5.0%
3.0%
3.0%
3.0%
3.0%
3.0%
SETUP, RISE, HOLD UP TIME 4000ms, 100ms, 30ms / 230VAC
VOLTAGE RANGE
90 ~ 264VAC 135 ~ 370VDC
4000ms, 100ms, 10ms / 115VAC at full load
FREQUENCY RANGE
47 ~ 63Hz
INPUT
EFFICIENCY (Typ.)
AC CURRENT
76.5%
79.5%
81.5%
82.5%
84%
84%
85%
85%
0.7A / 100VAC 0.4A / 230VAC
INRUSH CURRENT (max.) COLD START 40A / 100VAC 80A / 230VAC
LEAKAGE CURRENT (max.) 0.25mA / 240VAC
OVERLOAD
PROTECTION
OVER VOLTAGE
110% ~ 200% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
115% ~ 135%
Protection type : Clamp by zener diode
WORKING TEMP.
-10 ~ +50 (Refer to "Derating Curve")
WORKING HUMIDITY
20% ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -20 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03% / (0 ~ 50 )
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL60950-1, CSA C22.2, TUV EN60950 -1, CCC GB4943 approved
SAFETY & WITHSTAND VOLTAGE
EMC
ISOLATION RESISTANCE
EMC EMISSION
EMC IMMUNITY
LIFE
I/P-O/P:4242VDC
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022, EN61000-3-2,3, FCC part15, GB9254 class B
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
2 years : 100% load 30 , 8 hours / day
OTHERS
MTBF
DIMENSION
PACKING
100Khrs min. MIL-HDBK-217F (25 )
81*43*40.5mm (L*W*H)
134g ; 60pcs / 12.32kg / CARTON
DC OUTPUT PLUG
CONNECTOR CABLE
Standard type P1J: 2.1 * 5.5 * 11mm turning fork type, center positive for stock ; Other type available by customer requested
See page2
NOTE
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.Tolerance: includes set up tolerance, line regulation, load regulation.
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 10% to 100% rated load
7.Main body unit and AC inlet plug should be ordered seperately ; it needs to be used along with any of the AC inlet plug.
File Name:GE24-SPEC 2011-06-14