English
Language : 

GC30B Datasheet, PDF (1/2 Pages) Mean Well Enterprises Co., Ltd. – 16.8 ~ 30W Power Adaptor with Charging Function
16.8 ~ 30W Power Adaptor with Charging Function
GC30B series
Features :
SPECIFICATION
Universal AC input / Full range
2 pole AC Inlet IEC320-C8
Class power (without earth pin)
No load power consumption <1.0W
Constant current and voltage(CC,CV mode)
Suitable for continue load
For high surge current equipment
Protections: Short circuit / Overload / Over voltage / Over temp.
2 colors LED indicate for charging status
Fully enclosed plastic case
High reliability
Approvals: UL / CUL / TUV / CB / FCC / CE
2 years warranty
TUV
Rheinland
Product Safety
geprUfre
Sicherheit
ORDER NO.
GC30B-0P1J GC30B-1P1J GC30B-11P1J GC30B-2P1J GC30B-4P1J GC30B-5P1J GC30B-6P1J
SAFETY MODEL NO.
GC30B-0
GC30B-1
GC30B-11
GC30B-2
GC30B-4
GC30B-5
GC30B-6
DC VOLTAGE SET AT Note.2 4.2V
5.6V
7.2V
8.4V
14.3V
16.8V
28.6V
RATED CURRENT
4A
3.99A
3A
3A
2.09A
1.6A
1.04A
CURRENT RANGE
0 ~ 4A
0 ~ 3.99A
0 ~ 3A
0 ~3A
0 ~ 2.09A
0 ~ 1.6A
0 ~ 1.04A
OUTPUT
RATED POWER
16.8W
22.38W
21.6W
RIPPLE & NOISE (max.) Note.3 50mVp-p
50mVp-p
80mVp-p
CHARGING VOLTAGE RANGE Note.4 3.6 ~ 4.4V
5 ~ 5.8V
6.5 ~ 7.5V
LINE REGULATION Note.5 1.0%
0.5%
0.5%
LED INDICATOR
Green LED ON <150 ~ 200mA < Red LED ON
25.2W
80mVp-p
7.7 ~ 8.6V
0.5%
30W
100mVp-p
13.5 ~ 14.5V
0.5%
27W
100mVp-p
16 ~ 17V
0.5%
30W
150mVp-p
27.1 ~ 28.8V
0.5%
SETUP, RISE, HOLD UP TIME 200ms, 50ms, 16ms at full load
VOLTAGE RANGE
90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.)
55%
70%
74%
76%
78%
78%
80%
INPUT
AC CURRENT
1A / 100VAC
INRUSH CURRENT (max.) 40A / 230VAC
LEAKAGE CURRENT(max.) 0.25mA / 240VAC
OVERLOAD
PROTECTION OVER VOLTAGE
90 ~ 110% Constant current mode and over 300% pulsing mode
Protection type : Constant current limiting, recovers automatically after fault condition is removed
110 ~ 135% rated output voltage
Protection type : Clamp by zener diode
OVER TEMPERATURE
IC1Tj130
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
WORKING TEMP.
0 ~ +50 (Refer to output load derating curve)
WORKING HUMIDITY
20% ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -20 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03% / (0 ~ 50 )
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL60950-1, CSA22.2, EN60950-1 approved
WITHSTAND VOLTAGE
I/P-O/P:3KVAC
SAFETY & ISOLATION RESISTANCE I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
EMC
EMI CONDUCTION & RADIATION Compliance to EN55014-1 class B, FCC part 15 Class B
HARMONIC CURRENT
Compliance to EN61000-3-2,3
EMS IMMUNITY
DIMENSION
OTHERS PACKING
PLUG
CONNECTOR CABLE
Compliance to EN61000-4-2,3,4,5,6,11, light industry level, criteria A
108*67*36mm (L*W*H)
309g; 54pcs / 19kg / CARTON
Standard type P1J: 2.1 * 5.5 * 11mm, tuning fork type center positive for stock ; Other type available by customer requested
Standard type 18Awg UL1185 6ft and 4ft for 4.2V~8.4V output only for stock ; Other type available by customer requested
NOTE
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.
2.DC voltage: The output voltage set at point measure by plug terminal & 0% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.Output charging voltage range is measured from 0% to 100% rated load.
5.Line regulation is measured from low line to high line at rated load.
File Name:GC30B-SPEC 2008-05-08