English
Language : 

GC160_11 Datasheet, PDF (1/2 Pages) Mean Well Enterprises Co., Ltd. – 160W Single Output Battery Charger
160W Single Output Battery Charger
GC160 series
Features :
2 stage charging characteristic
Universal AC input / Full range
Built-in active PFC function, PF>0.94
No load power consumption<1W
3 pole AC inlet IEC320-C14
Class I power ( with earth pin)
Protections: Short circuit / Overload / Over voltage / Over temperature
Cooling by free air convection
Fully enclosed plastic case
2 color LED indicator for charging status
Approvals: TUV / UL / CB / FCC / CE
2 years warranty
TUV
Rheinland
Product Safety
geprUfre
Sicherheit
( for GC160Axx-AD1 only)
ORDER NO.
OUTPUT CONNECTOR
GC160Axx-R7B (standard model)
4pin power din
GC160Axx-AD1 (optional model)
Anderson connector
GC160Axx- xx=12,24,48 ; =R7B,AD1
SAFETY
TUV / CB / FCC / CE
UL / TUV / CB / FCC / CE
SPECIFICATION
ORDER NO.
GC160A12-
GC160A24-
GC160A48-
SAFETY MODEL NO.
DC VOLTAGE (Typ.)
GC160A12
13.6V
GC160A24
27.2V
GC160A48
54.4V
OUTPUT
RECOMMENDED BATTERY
CAPACITY
Note.2
60 ~160Ah
CONTINUOS OUTPUT
CURRENT (Typ.)
10A
30 ~ 90Ah
5.89A
15 ~ 45Ah
2.95A
RATED POWER
136W
160.2W
160.5W
LED INDICATOR
Charging(CC) : RED Floating charging(CV) : GREEN
VOLTAGE RANGE Note.3 85 ~ 264VAC 120 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.94 / 230VAC PF>0.98 / 115VAC at full load
INPUT EFFICIENCY (Typ.)
89%
92.5%
94%
AC CURRENT
1.85A / 115VAC 1A / 230VAC
INRUSH CURRENT (max.) 120A / 230VAC
LEAKAGE CURRENT(max.) 0.75mA / 240VAC
OVERLOAD
90 ~ 110% rated output power
Note.4
Protection type : Constant current limiting recovers automatically after fault condition is removed
SHORT CIRCUIT
Protection type : Hiccup mode, recovers automatically after fault condition is removed
PROTECTION
OVER VOLTAGE
105 ~ 135% rated output voltage
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE
90 10 (RTH2) detect on inside ambient temperature
Protection type : Shut down o/p voltage, re-power on to recover
WORKING TEMP.
-30 ~ +70 (Refer to "Derating Curve")
WORKING HUMIDITY
20% ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03% / (0~50 )
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL1012 (for GC160Axx-AD1 only), TUV EN60950-1 approved
SAFETY & WITHSTAND VOLTAGE
EMC
ISOLATION RESISTANCE
(Note. 5) EMC EMISSION
I/P-O/P: 3KVAC
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 class B, FCC PART 15 class B / CISPR22 class B, EN61000-3-2,3
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
MTBF
274.1Khrs min. MIL-HDBK-217F(25 )
OTHERS DIMENSION
PACKING
175*72*35mm (L*W*H)
0.7Kg; 20pcs/15Kg/0.85CUFT(GC160Axx-R7B)
0.77Kg; 20pcs/16.4Kg/1.15CUFT(GC160Axx-AD1)
PLUG
CONNECTOR
CABLE
See page 2 ; Other type available by customer requested
See page 2 ; Other type available by customer requested
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. This is MeanWell's suggested range, please consult your battery manufacturer for their suggestions about maximum charging current limitation.
3. Derating may be needed under low input voltage. Please check the derating curve for more details.
4. Constant current operation region is within 50~100% rated output voltage.
5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:GC160-SPEC 2011-08-09